In this study, subjective wear trials were conducted on 8 surgeons in operating rooms to investigate comfort performances of surgical gowns, an important component of medical protective equipments. Comfort performances of polypropylene SSMMS (S:Spunlace, M:Meltblown) and cellulose/polyester spunlace disposable and cotton/polyester woven reusable gowns were investigated by subjective evaluations. According to the results, SSMMS disposable gown was felt significantly to be warmer and damper, hence, its comfort performance was lower than the other gowns. Moreover, according to the sensory descriptive evaluations considering other aspects of comfort, disposable surgical gowns have lower comfort performances than the woven reusable gown and this result can be attributed to their insufficient permeability values and 'papery' feeling perceived by the surgeons. 

TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ

Year 2012, Volume: 19 Issue: 87, 6 - 14, 01.08.2012
https://doi.org/10.7216/130075992012198702

Abstract

Bu çalışmada, medikal koruyucu giysiler içerisinde en önemli bileşenlerden biri olan cerrahi önlüklerin konfor performansları 8 kişilik bir cerrah grubu üzerinde gerçekleştirilen alan giyim denemeleri ile incelenmiştir. Polipropilenden beş katlı SSMMS (S:Spunbond/Eriyikten çekim, M:Meltblown/Eriyikten üfleme), poliester/selüloz spunlace (su jetli) tek kullanımlık ve pamuk/poliester çok kullanımlık dokuma önlükler incelenmiştir. Önlüklerin seçilen standart bir operasyon sırasında kullanımları sırasında gönüllülerden alınan subjektif verilere göre, tek kullanımlık SSMMS önlüğün daha yüksek sıcaklık ve ıslaklık hislerine neden olduğu ve konfor performansının daha düşük olduğu tespit edilmiştir. Konforun tüm bileşenlerini yansıtan tanımlayıcı sıfat değerlendirmelerine göre ise, tek
kullanımlık önlüklerin çok kullanımlık önlüğe göre daha konforsuz hissettirdikleri belirlenmiştir. Bu durumun dokusuz yüzey kumaşların yetersiz geçirgenlik değerleri ve verdikleri 'kağıt benzeri' histen kaynaklandığı düşünülmektedir. 

There are 0 citations in total.

Details

Primary Language Turkish
Subjects Engineering
Journal Section Articles
Authors

Sibel Kaplan This is me

Mehtap Aksüzek This is me

Esin Acar This is me

Publication Date August 1, 2012
Published in Issue Year 2012 Volume: 19 Issue: 87

Cite

APA Kaplan, S., Aksüzek, M., & Acar, E. (2012). TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ. Tekstil Ve Mühendis, 19(87), 6-14. https://doi.org/10.7216/130075992012198702
AMA Kaplan S, Aksüzek M, Acar E. TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ. Tekstil ve Mühendis. August 2012;19(87):6-14. doi:10.7216/130075992012198702
Chicago Kaplan, Sibel, Mehtap Aksüzek, and Esin Acar. “TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ”. Tekstil Ve Mühendis 19, no. 87 (August 2012): 6-14. https://doi.org/10.7216/130075992012198702.
EndNote Kaplan S, Aksüzek M, Acar E (August 1, 2012) TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ. Tekstil ve Mühendis 19 87 6–14.
IEEE S. Kaplan, M. Aksüzek, and E. Acar, “TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ”, Tekstil ve Mühendis, vol. 19, no. 87, pp. 6–14, 2012, doi: 10.7216/130075992012198702.
ISNAD Kaplan, Sibel et al. “TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ”. Tekstil ve Mühendis 19/87 (August 2012), 6-14. https://doi.org/10.7216/130075992012198702.
JAMA Kaplan S, Aksüzek M, Acar E. TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ. Tekstil ve Mühendis. 2012;19:6–14.
MLA Kaplan, Sibel et al. “TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ”. Tekstil Ve Mühendis, vol. 19, no. 87, 2012, pp. 6-14, doi:10.7216/130075992012198702.
Vancouver Kaplan S, Aksüzek M, Acar E. TEK VE ÇOK KULLANIMLIK CERRAHİ ÖNLÜKLERİN TERMAL KONFOR PERFORMANSLARININ SUBJEKTİF ALAN GİYİM DENEMELERİ İLE BELİRLENMESİ. Tekstil ve Mühendis. 2012;19(87):6-14.