Purpose: In this study, it was aimed to investigate whether beta-2 microglobulin (β2M) blood plasma level is affected by cardiopulmonary bypass (CPB) and its effects on prognosis in surgeries performed using a heart-lung machine.
Material and Methods: The study was carried out on 33 patients who underwent cardiac surgery using a heart-lung machine in the cardiovascular surgery department of Sivas Cumhuriyet University. Plasma β2M levels were evaluated in peripheral venous blood samples taken just before the operation, thirty minutes after connecting to the heart-lung machine, and at the twenty-fourth postoperative hour.
Results: It was observed that a high β2M level was associated with long intensive care and hospital stay, prolonged intubation, increased inotrope requirement, and blood product use (P<.001). In addition; advanced age, tobacco use, hyperlipidemia, and hypertension were also associated with high β2M levels (P<.001). It was observed that the heart-lung machine did not affect the plasma β2M level (P=0.843).
Conclusion: The heart-lung machine did not affect the plasma β2M levels. However, it seems likely that high β2M levels can be used as a predictive marker for poor prognosis in open heart surgery.
Keywords: Beta-2 microglobulin, Cardiac surgery, Cardiopulmonary bypass machine, Open heart surgery
Keywords
Project Number
yok
References
- REFERENCES
- Referans1 Amighi, J., Hoke, M., Mlekusch, W. et al. (2011). Beta 2 Microglobulin and the Risk for Cardiovascular Events in Patients With Asymptomatic Carotid Atherosclerosis. Stroke, 42(7), 1826-1833. doi:doi:10.1161/STROKEAHA.110.600312
- Referans2 Bethea, M., and Forman, D. (1990). Beta 2-microglobulin: its significance and clinical usefulness. Annals of Clinical & Laboratory Science, 20(3), 163-168.
- Referans3 BMY, C., FCC, T., CL, C. et al. (2016). GW27-e0922 Beta-2 microglobulin level in serum is elevated in patients presenting with acute coronary syndrome. Journal of the American College of Cardiology, 68(16_Supplement), C97-C97. doi:doi:10.1016/j.jacc.2016.07.363
- Referans4 Cheung, B., Tam, F., Cheung, C. et al. (2017). Serum Beta-2 Microglobulin Level is Elevated in Patients with Acute Coronary Syndrome. Clinical Therapeutics, 39(8), e52.
- Referans5 Çalışal, M. A. (2013). The effects of single and dual reservoired oxygenators on inflammatory response in cardiopulmonary bypass. Turkish Journal of Thoracic and Cardiovascular Surgery, 21(2).
- Referans6 Huang, Y., Lin, Y., Zhai, X. et al. (2022). Association of Beta-2-Microglobulin With Coronary Heart Disease and All-Cause Mortality in the United States General Population. Front Cardiovasc Med, 9, 834150. doi:10.3389/fcvm.2022.834150
- Referans7 Johnson Jr, H., Flye, M. W., and Javadpour, N. (1980). Serum β2 microglobulin levels in patients with testicular cancer. Urology, 16(5), 522-524.
Details
Primary Language
English
Subjects
Primary Health Care
Journal Section
Clinical Research
Publication Date
January 31, 2023
Submission Date
January 21, 2023
Acceptance Date
January 28, 2023
Published in Issue
Year 2023 Volume: 4 Number: 1
APA
Polat, V., & Ada, F. (2023). Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. Turkish Journal of Science and Health, 4(1), 71-76. https://doi.org/10.51972/tfsd.1239933
AMA
1.Polat V, Ada F. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 2023;4(1):71-76. doi:10.51972/tfsd.1239933
Chicago
Polat, Vural, and Fatih Ada. 2023. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health 4 (1): 71-76. https://doi.org/10.51972/tfsd.1239933.
EndNote
Polat V, Ada F (January 1, 2023) Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. Turkish Journal of Science and Health 4 1 71–76.
IEEE
[1]V. Polat and F. Ada, “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”, TFSD, vol. 4, no. 1, pp. 71–76, Jan. 2023, doi: 10.51972/tfsd.1239933.
ISNAD
Polat, Vural - Ada, Fatih. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health 4/1 (January 1, 2023): 71-76. https://doi.org/10.51972/tfsd.1239933.
JAMA
1.Polat V, Ada F. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 2023;4:71–76.
MLA
Polat, Vural, and Fatih Ada. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health, vol. 4, no. 1, Jan. 2023, pp. 71-76, doi:10.51972/tfsd.1239933.
Vancouver
1.Vural Polat, Fatih Ada. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 2023 Jan. 1;4(1):71-6. doi:10.51972/tfsd.1239933