Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level

Cilt: 4 Sayı: 1 31 Ocak 2023
PDF İndir
EN TR

Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level

Öz

Purpose: In this study, it was aimed to investigate whether beta-2 microglobulin (β2M) blood plasma level is affected by cardiopulmonary bypass (CPB) and its effects on prognosis in surgeries performed using a heart-lung machine. Material and Methods: The study was carried out on 33 patients who underwent cardiac surgery using a heart-lung machine in the cardiovascular surgery department of Sivas Cumhuriyet University. Plasma β2M levels were evaluated in peripheral venous blood samples taken just before the operation, thirty minutes after connecting to the heart-lung machine, and at the twenty-fourth postoperative hour. Results: It was observed that a high β2M level was associated with long intensive care and hospital stay, prolonged intubation, increased inotrope requirement, and blood product use (P<.001). In addition; advanced age, tobacco use, hyperlipidemia, and hypertension were also associated with high β2M levels (P<.001). It was observed that the heart-lung machine did not affect the plasma β2M level (P=0.843). Conclusion: The heart-lung machine did not affect the plasma β2M levels. However, it seems likely that high β2M levels can be used as a predictive marker for poor prognosis in open heart surgery. Keywords: Beta-2 microglobulin, Cardiac surgery, Cardiopulmonary bypass machine, Open heart surgery

Anahtar Kelimeler

Destekleyen Kurum

yok

Proje Numarası

yok

Teşekkür

Biyokimya anabilim dalı öğretim üyesi Doç. Dr. Halef Okan Doğan'a materyallerin saklanmasındaki işbirliği için teşekkür ederiz

Kaynakça

  1. REFERENCES
  2. Referans1 Amighi, J., Hoke, M., Mlekusch, W. et al. (2011). Beta 2 Microglobulin and the Risk for Cardiovascular Events in Patients With Asymptomatic Carotid Atherosclerosis. Stroke, 42(7), 1826-1833. doi:doi:10.1161/STROKEAHA.110.600312
  3. Referans2 Bethea, M., and Forman, D. (1990). Beta 2-microglobulin: its significance and clinical usefulness. Annals of Clinical & Laboratory Science, 20(3), 163-168.
  4. Referans3 BMY, C., FCC, T., CL, C. et al. (2016). GW27-e0922 Beta-2 microglobulin level in serum is elevated in patients presenting with acute coronary syndrome. Journal of the American College of Cardiology, 68(16_Supplement), C97-C97. doi:doi:10.1016/j.jacc.2016.07.363
  5. Referans4 Cheung, B., Tam, F., Cheung, C. et al. (2017). Serum Beta-2 Microglobulin Level is Elevated in Patients with Acute Coronary Syndrome. Clinical Therapeutics, 39(8), e52.
  6. Referans5 Çalışal, M. A. (2013). The effects of single and dual reservoired oxygenators on inflammatory response in cardiopulmonary bypass. Turkish Journal of Thoracic and Cardiovascular Surgery, 21(2).
  7. Referans6 Huang, Y., Lin, Y., Zhai, X. et al. (2022). Association of Beta-2-Microglobulin With Coronary Heart Disease and All-Cause Mortality in the United States General Population. Front Cardiovasc Med, 9, 834150. doi:10.3389/fcvm.2022.834150
  8. Referans7 Johnson Jr, H., Flye, M. W., and Javadpour, N. (1980). Serum β2 microglobulin levels in patients with testicular cancer. Urology, 16(5), 522-524.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Birinci Basamak Sağlık Hizmetleri

Bölüm

Klinik Araştırma

Yayımlanma Tarihi

31 Ocak 2023

Gönderilme Tarihi

21 Ocak 2023

Kabul Tarihi

28 Ocak 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 4 Sayı: 1

Kaynak Göster

APA
Polat, V., & Ada, F. (2023). Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. Turkish Journal of Science and Health, 4(1), 71-76. https://doi.org/10.51972/tfsd.1239933
AMA
1.Polat V, Ada F. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 2023;4(1):71-76. doi:10.51972/tfsd.1239933
Chicago
Polat, Vural, ve Fatih Ada. 2023. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health 4 (1): 71-76. https://doi.org/10.51972/tfsd.1239933.
EndNote
Polat V, Ada F (01 Ocak 2023) Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. Turkish Journal of Science and Health 4 1 71–76.
IEEE
[1]V. Polat ve F. Ada, “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”, TFSD, c. 4, sy 1, ss. 71–76, Oca. 2023, doi: 10.51972/tfsd.1239933.
ISNAD
Polat, Vural - Ada, Fatih. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health 4/1 (01 Ocak 2023): 71-76. https://doi.org/10.51972/tfsd.1239933.
JAMA
1.Polat V, Ada F. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 2023;4:71–76.
MLA
Polat, Vural, ve Fatih Ada. “Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level”. Turkish Journal of Science and Health, c. 4, sy 1, Ocak 2023, ss. 71-76, doi:10.51972/tfsd.1239933.
Vancouver
1.Vural Polat, Fatih Ada. Evaluation of the Effects of the Heart-Lung Machine on the Plasma Beta-2 Microglobulin Level. TFSD. 01 Ocak 2023;4(1):71-6. doi:10.51972/tfsd.1239933