Case Report
BibTex RIS Cite

Katlanabilir Göziçi Lenslerde Katlantı İzi

Year 2007, Volume: 1 Issue: 1, 49 - 52, 20.03.2007

Abstract

Fakoemülsifıkasyonla lens cerrahisi ve küçük keşiden yerleştirilebilen katlanabilir göz çi lenslerin geliştirilmesi, katarakt cerrahisinde önemli bir gelişme olmakla birlikte, bu lenslere ait komplikasyonlar da bildirilmektedir. Bir tür katlanabilir göz içi lens kullandığımız iki komplikasyonsuz fakoemülsifıkasyon cerrahisi uyguladığımız olgumuzda, post operatuar dönemde saptadığımız katlantı izleri önemli bir sorun olarak dikkatimizi çekmiştir.

Abstract
Cataract surgery with phacoemulsification and usage of intraocular foldable lenses that can be implanted by small incisions are important developments in cataract surgery. However, complications of these foldable lenses have also been reported. Here we have noticed postoperative cracks in the foldable lenses as an important complication in our two cases with otherwise uncomplicated phacoemulsification surgery.

References

  • 1. Friedman DS, West SK, Munoz B, et al. Racial variations in causes of vision loss in nursing homes: The Salisbury Eye Evaluation in Nursing Home Groups (SEEING) Study, Arch Ophthalmol 2004;122:1019-24.
  • 2. Köhnen T, Lambert RJ, Koch DD. Incision sizes for foldo-ble intraocular lenses. Ophthalmology 1997;104:1277-86.
  • 3. Mamalis N. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2001 survey update. J Cataract Refract Surg 2002;28:2193-201.
  • 4. Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2003 survey update. J Cataract Refract Surg 2004;30:2209-18.
  • 5. Rath R, Singh AD, Singh A. Catridge cracks during foldable intraocular lens insertion. J Cataract Refract Surg 1999;25:306.
  • 6. Mamalis N, Spencer TS. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2000 survey update. J Cataract Refract Surg 2001;27:1310-7.
  • 7. Werner L, Apple DJ, Kaşlakoğlu M, Pandey SK. Dense opacification of a hydrophilic acrylic intraocular lens: A clinicopayhological analysis of 9 explanted lenses. J Cataract Refract Surg 2001;27:1485-92.
  • 8. Yu AKF, Shek TWH. Hydroxyapatite formation on implanted hydrogel intraocular lenses. Arch Ophthamol 2001;119:611-4.
  • 9. Schmidbauer JM, Peng Q, Apple DJ, et al. Rates and causes of intraoperative removal of foldable and rigid intraocular lenses: clinicopathological analysis of 100 cases. J Cataract Refract Surg 2002;28:1223-8
  • 10. Sigh AD, Fang T, Rath R. Catridge cracks during foldable intraocular lens insertion. J Cataract Refract Surg 1998;24:1220-2.
  • 11. Auffarth GU, Hulzer MP, Vıssesook N, Apple DJ, Volcker HE. Removal times and techniques of a viscoadop-tive ophthalmic viscosurgical device. J Cataract Refract Surg 2004;30:879-83.
  • 12. Holzer MP, Tetz MR, Aufforth GU, Welt R, Volcker HE. Effect of Healon 5 and 4 other viscoelastic Substances on intraocalor pressure and endothelium after cataract Surgery. J Cataract Refract Surg 2001;27:213-8.
Year 2007, Volume: 1 Issue: 1, 49 - 52, 20.03.2007

Abstract

References

  • 1. Friedman DS, West SK, Munoz B, et al. Racial variations in causes of vision loss in nursing homes: The Salisbury Eye Evaluation in Nursing Home Groups (SEEING) Study, Arch Ophthalmol 2004;122:1019-24.
  • 2. Köhnen T, Lambert RJ, Koch DD. Incision sizes for foldo-ble intraocular lenses. Ophthalmology 1997;104:1277-86.
  • 3. Mamalis N. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2001 survey update. J Cataract Refract Surg 2002;28:2193-201.
  • 4. Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2003 survey update. J Cataract Refract Surg 2004;30:2209-18.
  • 5. Rath R, Singh AD, Singh A. Catridge cracks during foldable intraocular lens insertion. J Cataract Refract Surg 1999;25:306.
  • 6. Mamalis N, Spencer TS. Complications of foldable intraocular lenses requiring explantation or secondary intervention-2000 survey update. J Cataract Refract Surg 2001;27:1310-7.
  • 7. Werner L, Apple DJ, Kaşlakoğlu M, Pandey SK. Dense opacification of a hydrophilic acrylic intraocular lens: A clinicopayhological analysis of 9 explanted lenses. J Cataract Refract Surg 2001;27:1485-92.
  • 8. Yu AKF, Shek TWH. Hydroxyapatite formation on implanted hydrogel intraocular lenses. Arch Ophthamol 2001;119:611-4.
  • 9. Schmidbauer JM, Peng Q, Apple DJ, et al. Rates and causes of intraoperative removal of foldable and rigid intraocular lenses: clinicopathological analysis of 100 cases. J Cataract Refract Surg 2002;28:1223-8
  • 10. Sigh AD, Fang T, Rath R. Catridge cracks during foldable intraocular lens insertion. J Cataract Refract Surg 1998;24:1220-2.
  • 11. Auffarth GU, Hulzer MP, Vıssesook N, Apple DJ, Volcker HE. Removal times and techniques of a viscoadop-tive ophthalmic viscosurgical device. J Cataract Refract Surg 2004;30:879-83.
  • 12. Holzer MP, Tetz MR, Aufforth GU, Welt R, Volcker HE. Effect of Healon 5 and 4 other viscoelastic Substances on intraocalor pressure and endothelium after cataract Surgery. J Cataract Refract Surg 2001;27:213-8.
There are 12 citations in total.

Details

Primary Language Turkish
Subjects Clinical Sciences (Other)
Journal Section Case Reports
Authors

Ayşegül Koçak Altıntaş

Publication Date March 20, 2007
Published in Issue Year 2007 Volume: 1 Issue: 1

Cite

APA Koçak Altıntaş, A. (2007). Katlanabilir Göziçi Lenslerde Katlantı İzi. Turkish Medical Journal, 1(1), 49-52.

bf8427c2c5be3a8e93ed095426efd16e.png
Bu eser Creative Commons Atıf-GayriTicari (CC-BY-NC 4.0) Uluslararası Lisansı ile lisanslanmıştır.

All site content, except where otherwise noted, is licensed under a Creative Common Attribution Licence. (CC-BY-NC 4.0)