BibTex RIS Cite

A Percutaneous Coronary Intervention Complication: Coronary Perforation

Year 2013, Volume: 20 Issue: 4, 338 - 340, 01.08.2013

Abstract

Coronary perforation is the most feared and lethal complication in the catheterization laboratories. Perforation incidence is reported to be between 0,2 - 0,6%. Sixty nine year-old patient with a typical angina pectoris and having a positive effort test was admitted to the catheter laboratory for coronary angiography. In the coronary angiography, Biomime stent was deployed with nominal pressure to the mid segment of the left anterior descending (LAD) artery which was found to have a 80% stenosis. In order to obtain optimal expansion, postdilatation was performed with a powerline balloon. After postdilatation, Ellis grade III perforation was developed. Bleeding control was achieved with implantation of a 3,0×19 mm graft stent to the perforation site. In the echocardiographic investigations, the patient did not exhibit any pericardial fluid and tamponade findings so the patient was discharged after 48 hours. Key words: Percutaneous Coronary Intervention; Coronary Perforation; Covered Stent.

References

  • www.jtomc.org DISCUSSION Turgut Özal Tıp Merkezi Dergisi 340

Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon

Year 2013, Volume: 20 Issue: 4, 338 - 340, 01.08.2013

Abstract

Koroner perforasyon, kateterizasyon laboratuvarının en korkulan ve ölümcül olabilen komplikasyonudur. Perforasyon sıklığı %0,2-0,6 olarak bildirilmiştir. Koroner perforasyonda, işlemi yapan kardiyologun kılavuzlarda bildirilen yetkinliğe sahip olması, kateter laboratuvarında covered stent bulunması hayat kurtarıcı olmaktadır. Efor testi pozitif olan, tipik anjina tanımlayan 69 yaşındaki hasta koroner anjiografi için kateter laboratuvarın alındı. Koroner anjiografide sol ön inen koroner arter (LAD) orta segmentte saptanan %80 darlığa Biomime stent nominal basınçla yerleştirildi. Optimal açılımı sağlamak için powerline balon ile postdilatasyon uygulandı. Postdilatasyon sonucu Ellis grade III perforasyon gelişti. Perforasyon bölgesine 3,0×19 mm graft stent implante edildi. Yapılan ekokardiyografi incelemelerinde perikardial mayii ve tamponat bulguları saptanmayan hasta stabil olarak taburcu edildi. Anahtar kelimeler: Perkutan Koroner Girişim; Koroner Perforasyon; Kaplı Stent.

References

  • www.jtomc.org DISCUSSION Turgut Özal Tıp Merkezi Dergisi 340
There are 1 citations in total.

Details

Primary Language Turkish
Journal Section Articles
Authors

Abdulmelik Yıldız This is me

Bayram Bağırtan This is me

Publication Date August 1, 2013
Published in Issue Year 2013 Volume: 20 Issue: 4

Cite

APA Yıldız, A., & Bağırtan, B. (2013). Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. Journal of Turgut Ozal Medical Center, 20(4), 338-340.
AMA Yıldız A, Bağırtan B. Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. J Turgut Ozal Med Cent. August 2013;20(4):338-340.
Chicago Yıldız, Abdulmelik, and Bayram Bağırtan. “Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon”. Journal of Turgut Ozal Medical Center 20, no. 4 (August 2013): 338-40.
EndNote Yıldız A, Bağırtan B (August 1, 2013) Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. Journal of Turgut Ozal Medical Center 20 4 338–340.
IEEE A. Yıldız and B. Bağırtan, “Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon”, J Turgut Ozal Med Cent, vol. 20, no. 4, pp. 338–340, 2013.
ISNAD Yıldız, Abdulmelik - Bağırtan, Bayram. “Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon”. Journal of Turgut Ozal Medical Center 20/4 (August 2013), 338-340.
JAMA Yıldız A, Bağırtan B. Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. J Turgut Ozal Med Cent. 2013;20:338–340.
MLA Yıldız, Abdulmelik and Bayram Bağırtan. “Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon”. Journal of Turgut Ozal Medical Center, vol. 20, no. 4, 2013, pp. 338-40.
Vancouver Yıldız A, Bağırtan B. Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. J Turgut Ozal Med Cent. 2013;20(4):338-40.