Abstract

The aim of this study is to investigate the thermodynamic performance of a refrigeration system for a cold storage using natural refrigerants which can be considered as substitutes of CFC, HCFC and HFC type working fluids. As these kinds of refrigerants menace the environment because of their higher ozone depletion and global warming potentials, the investigations are focused on new alternative refrigerants. For this purpose, seven natural refrigerants and three chlorine based ones are analyzed in terms of first and second laws of thermodynamic. The analyses are made for a refrigeration capacity of 98.46 kW and cold room temperature of -2 °C. The energy performance indicator COP, exergy performance indicator exergy efficiency and exergy destruction rates of the system are determined. The results are showed that the best COP value is obtained using R600a with a value of 2.5. According to the exergy analyses, the refrigerant R600a has the highest exergetic efficiency rate with 24.9 %. Also the highest exergy destruction rates occurred using R170 and R744 with 57.47 and 56.63 kW, respectively.

Keywords

References

  1. AGDE, (2015). Australian Government Department of the Environment. http://www.environment.gov.au/protection/ozone/publications/natural-refrigerants- case-studies, accessed 22.01.2015. R717 R717 R600 R600 R600a R600a

Details

Primary Language

Turkish

Subjects

-

Journal Section

-

Authors

Önder Kızılkan This is me

Publication Date

September 1, 2015

Submission Date

September 1, 2015

Acceptance Date

-

Published in Issue

Year 2015 Volume: 7 Number: 3

APA
Kızılkan, Ö. (2015). DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA. Uluslararası Teknolojik Bilimler Dergisi, 7(3), 1-15. https://izlik.org/JA69UR68XG
AMA
1.Kızılkan Ö. DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA. IJTS. 2015;7(3):1-15. https://izlik.org/JA69UR68XG
Chicago
Kızılkan, Önder. 2015. “DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA”. Uluslararası Teknolojik Bilimler Dergisi 7 (3): 1-15. https://izlik.org/JA69UR68XG.
EndNote
Kızılkan Ö (September 1, 2015) DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA. Uluslararası Teknolojik Bilimler Dergisi 7 3 1–15.
IEEE
[1]Ö. Kızılkan, “DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA”, IJTS, vol. 7, no. 3, pp. 1–15, Sept. 2015, [Online]. Available: https://izlik.org/JA69UR68XG
ISNAD
Kızılkan, Önder. “DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA”. Uluslararası Teknolojik Bilimler Dergisi 7/3 (September 1, 2015): 1-15. https://izlik.org/JA69UR68XG.
JAMA
1.Kızılkan Ö. DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA. IJTS. 2015;7:1–15.
MLA
Kızılkan, Önder. “DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA”. Uluslararası Teknolojik Bilimler Dergisi, vol. 7, no. 3, Sept. 2015, pp. 1-15, https://izlik.org/JA69UR68XG.
Vancouver
1.Önder Kızılkan. DOĞAL SOĞUTUCU AKIŞKANLARIN KARŞILAŞTIRMALI OLARAK İNCELENMESİ: SOĞUK DEPOLAMA UYGULAMASI İÇİN ÖRNEK BİR ÇALIŞMA. IJTS [Internet]. 2015 Sep. 1;7(3):1-15. Available from: https://izlik.org/JA69UR68XG