Abstract

Biocompatibility of hemodialysis is mainly referred to the reactions induced by extracorporeal materials in contact with the blood. Data regarding the effect of membran sterilization method on biocompatibility is limited. In this study, the effect of two polisulphon (PS) membranes, which were sterilized with different methods, on the complement, CRP, peripheral total lympocyte count and subsets in hemodialysis patients was investigated in a single dialysis session. 26 hemodialysis patients underwent hemodialysis with ethylene oxidesterilized PS (F5) membrane or with steam-sterilized PS (F5HPS) membrane for 4 hours. The aforementioned parameters were measured from the blood samples taken before and after the dialysis session from all patients. In both groups, complement and CRP levels were significantly increased following the dialysis. But there was no difference between the changes in two groups. While CD4 (helper/inducer T cell) and CD4/CD8 rates were significantly increased in both groups, the changes in F5 and F5HPS groups were similar. CD8 (supressor/cytotoxic T cell) levels in F5 group and DR (activated T cell) levels in F5HPS group decreased significantly. Although the changes in CD8 between two groups were not significant, the decrease in F5HPS group was significant compared to the increase in F5 group (-11.2% versus 23.7%). Our study suggested that the membran sterilization method in biocompatible syntethic membranes would lead to mild changes in lymphocyte subsets.

Keywords

Details

Primary Language

English

Subjects

-

Journal Section

-

Authors

Alpaslan Ersoy This is me

Emel Şenol This is me

Ferah Budak This is me

Müge Erek This is me

Songül İlkaya This is me

Göksel Kar This is me

Barboros Oral This is me

Mahmut Yavuz This is me

Publication Date

June 1, 2006

Submission Date

June 1, 2006

Acceptance Date

-

Published in Issue

Year 2006 Volume: 32 Number: 2

APA
Ersoy, A., Şenol, E., Budak, F., Erek, M., İlkaya, S., Kar, G., Oral, B., & Yavuz, M. (2006). The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients. Journal of Uludağ University Medical Faculty, 32(2), 49-53. https://izlik.org/JA64TA67FM
AMA
1.Ersoy A, Şenol E, Budak F, et al. The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients. Journal of Uludağ University Medical Faculty. 2006;32(2):49-53. https://izlik.org/JA64TA67FM
Chicago
Ersoy, Alpaslan, Emel Şenol, Ferah Budak, et al. 2006. “The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients”. Journal of Uludağ University Medical Faculty 32 (2): 49-53. https://izlik.org/JA64TA67FM.
EndNote
Ersoy A, Şenol E, Budak F, Erek M, İlkaya S, Kar G, Oral B, Yavuz M (June 1, 2006) The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients. Journal of Uludağ University Medical Faculty 32 2 49–53.
IEEE
[1]A. Ersoy et al., “The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients”, Journal of Uludağ University Medical Faculty, vol. 32, no. 2, pp. 49–53, June 2006, [Online]. Available: https://izlik.org/JA64TA67FM
ISNAD
Ersoy, Alpaslan - Şenol, Emel - Budak, Ferah - Erek, Müge - İlkaya, Songül - Kar, Göksel - Oral, Barboros - Yavuz, Mahmut. “The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients”. Journal of Uludağ University Medical Faculty 32/2 (June 1, 2006): 49-53. https://izlik.org/JA64TA67FM.
JAMA
1.Ersoy A, Şenol E, Budak F, Erek M, İlkaya S, Kar G, Oral B, Yavuz M. The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients. Journal of Uludağ University Medical Faculty. 2006;32:49–53.
MLA
Ersoy, Alpaslan, et al. “The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients”. Journal of Uludağ University Medical Faculty, vol. 32, no. 2, June 2006, pp. 49-53, https://izlik.org/JA64TA67FM.
Vancouver
1.Alpaslan Ersoy, Emel Şenol, Ferah Budak, Müge Erek, Songül İlkaya, Göksel Kar, Barboros Oral, Mahmut Yavuz. The Effect of Different Sterilization Methods on Lymphocyte Subsets in Hemodialysis Patients. Journal of Uludağ University Medical Faculty [Internet]. 2006 Jun. 1;32(2):49-53. Available from: https://izlik.org/JA64TA67FM

ISSN: 1300-414X, e-ISSN: 2645-9027

Creative Commons License
Journal of Uludag University Medical Faculty is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
2023