BibTex RIS Kaynak Göster

Flow Cytometric Analysis Of In Vitro Activation Markers Of Platelets Collected With Two Different Cell Separators

Yıl 2004, Cilt: 30 Sayı: 3, 173 - 180, 01.09.2004

Öz

The aim of this study was to compare in vitro activation markers of platelets collected with two different cell separators (Cobe Spectra and CS3000 plus) analysed by flow cytometry on day 0 and 3, to determine the relationship between platelet activation and storage time. 5O donor (5 women 45 men) aged between 20-49 (median age 33.4±8.7) who were good candidate for apheresis and who admitted to apheresis for the first time were selected for the study. The platelet activation markers of collections were assessed on day 0 and on day 3 by flow cytometry. The 0. day analysis was performed without time delay as soon as the concentrate was collected and 3. day analysis was performed on the product which was stored on ajitator. CD62 and CD63 expression percentage were high on the third day of storage in both collections of two cell separators Cobe Spectra and CS3000 plus.

İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi

Yıl 2004, Cilt: 30 Sayı: 3, 173 - 180, 01.09.2004

Öz

Bu çalışmanın amacı, iki farklı hücre ayırıcı Cobe Spectra ve CS3000 Plus cihazlarıyla toplanan trombosit süspansiyonlarının optimal şartlarda saklanarak, 0. ve 3. günlerdeki in vitro aktivasyon markırlarını (trombosit membran yüzey glikoprotein ekspresyonları) akım sitometrik yöntemle bakarak, değişik cihazlarda hazırlanan trombosit süspansiyonlarını karşılaştırmak, saklama zamanı ile trombosit aktivasyonu arasındaki ilişkiyi saptamaktır. Çalışmamız, Aferez Ünitesi'ne başvuran, aferez şartlarını taşıyan, ilk kez trombosit donörü olarak işleme alınan, yaşları 20-49 arasında değişen 5'i kadın, 45'i erkek (yaş ortalaması 33.4±8.7) olmak üzere, toplam 50 donör ile gerçekleştirildi. Örneklerden 0. günde bekletmeden oda ısısında, ajitatörde bekleterek 3. günde olmak üzere iki kez, akım sitometrik yöntemle in vitro trombosit aktivasyon markırları değerlendirildi. İki farklı hücre ayırıcıda da depolamanın 3. gününde CD62 ve CD63 ekspresyonu yüzdesi yüksek bulundu.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Diğer ID JA99PF52SH
Bölüm Özgün Araştırma Makaleleri
Yazarlar

Vildan Özkocaman Bu kişi benim

Fahir Özkalemkaş Bu kişi benim

Ferah Budak Bu kişi benim

Tülay Özçelik Bu kişi benim

Rıdvan Ali Bu kişi benim

Ahmet Tunalı Bu kişi benim

Yayımlanma Tarihi 1 Eylül 2004
Yayımlandığı Sayı Yıl 2004 Cilt: 30 Sayı: 3

Kaynak Göster

APA Özkocaman, V., Özkalemkaş, F., Budak, F., Özçelik, T., vd. (2004). İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi. Uludağ Üniversitesi Tıp Fakültesi Dergisi, 30(3), 173-180.
AMA Özkocaman V, Özkalemkaş F, Budak F, Özçelik T, Ali R, Tunalı A. İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi. Uludağ Tıp Derg. Eylül 2004;30(3):173-180.
Chicago Özkocaman, Vildan, Fahir Özkalemkaş, Ferah Budak, Tülay Özçelik, Rıdvan Ali, ve Ahmet Tunalı. “İki Farklı Hücre Ayırıcı Ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi”. Uludağ Üniversitesi Tıp Fakültesi Dergisi 30, sy. 3 (Eylül 2004): 173-80.
EndNote Özkocaman V, Özkalemkaş F, Budak F, Özçelik T, Ali R, Tunalı A (01 Eylül 2004) İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi. Uludağ Üniversitesi Tıp Fakültesi Dergisi 30 3 173–180.
IEEE V. Özkocaman, F. Özkalemkaş, F. Budak, T. Özçelik, R. Ali, ve A. Tunalı, “İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi”, Uludağ Tıp Derg, c. 30, sy. 3, ss. 173–180, 2004.
ISNAD Özkocaman, Vildan vd. “İki Farklı Hücre Ayırıcı Ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi”. Uludağ Üniversitesi Tıp Fakültesi Dergisi 30/3 (Eylül 2004), 173-180.
JAMA Özkocaman V, Özkalemkaş F, Budak F, Özçelik T, Ali R, Tunalı A. İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi. Uludağ Tıp Derg. 2004;30:173–180.
MLA Özkocaman, Vildan vd. “İki Farklı Hücre Ayırıcı Ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi”. Uludağ Üniversitesi Tıp Fakültesi Dergisi, c. 30, sy. 3, 2004, ss. 173-80.
Vancouver Özkocaman V, Özkalemkaş F, Budak F, Özçelik T, Ali R, Tunalı A. İki Farklı Hücre Ayırıcı ile Toplanan Trombositlerin Akım Sitometrik Yöntemle İn Vitro Aktivasyon Markırlarına Etkisinin İncelenmesi. Uludağ Tıp Derg. 2004;30(3):173-80.

ISSN: 1300-414X, e-ISSN: 2645-9027

Uludağ Üniversitesi Tıp Fakültesi Dergisi "Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License" ile lisanslanmaktadır.


Creative Commons License
Journal of Uludag University Medical Faculty is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

2023