Araştırma Makalesi

Determining the turnaround time in a newly established biochemistry laboratory

Cilt: 4 Sayı: 3 27 Eylül 2023
PDF İndir
EN

Determining the turnaround time in a newly established biochemistry laboratory

Öz

Background: The aim of our study was to compare the request-to-result times in the central biochemistry laboratory of Etlik City Hospital temporally and between clinics and to reveal the reasons for the changes in these times. Methods: The time of acceptance of the samples to the Central Biochemistry Laboratory of Etlik City Hospital and the time of confirmation of the results were noted and the difference between these two times was taken. Results: Delay rates were significantly different between the inpatients in October, November and December (P<0.001). For troponin tubes, the delay rates were significantly different between the inpatients in October, November and December (P<0.001). In the emergency department, the highest delay rate was for troponin: 73.8% and the lowest for hormone (12.1%), regardless of time. In the outpatient clinic, the highest delay rate was in biochemistry (43.2%) and the lowest in complete blood count (3.7%). When the tubes were compared according to the inpatients, it was observed that the highest percentage of delay was for troponin in the emergency department. Conclusions: The benefits we expect from our study are to clearly demonstrate the fast turnaround times of newly established biochemistry laboratories in large hospitals and centers, to show the changes in these times between clinics, to increase clinicians' satisfaction with the laboratory, to reduce costs by shortening hospital stay times and to develop measures that can be taken.

Anahtar Kelimeler

Turn-around time, City hospital, Laboratory, Efficiency

Destekleyen Kurum

Yok

Proje Numarası

Yok

Teşekkür

Yok

Kaynakça

  1. Pati HP, Singh G. Turnaround time (TAT): difference in concept for laboratory and clinician. Indian J Hematol Blood Transfus. 2014;30:81- 84.
  2. Howanitz JH, Howanitz PJ. Timeliness as a quality attribute and strategy. Am J Clin Pathol. 2001;116:311–315.
  3. Dighe AS, Rao A, Coakley AB, Lewandrowski KB. Analysis of laboratory critical value reporting at a large academic medical center. Am J Clin Pathol. 2006;1255:758-764.
  4. Dawande PP, Wankhade RS, Akhtar FI, Noman O. Turnaround Time: An Efficacy Measure for Medical Laboratories. Cureus. 2022;149:e28824.
  5. Manor PG. Turnaround times in the laboratory: a review of the literature. Clin Lab Sci. 1999;12:85–89.
  6. Guss DA, Chan TC, Killeen JP. The impact of a pneumatic tube and computerized physician order management on laboratory turnaround time. Ann Emerg Med. 2008;512:181-185.
  7. Storrow AB, Zhou C, Gaddis G, et al. Decreasing lab turnaround time improves emergency department throughput and decreases emergency medical services diversion: a simulation model. Acad Emerg Med. 2008;1511:1130-1135.
  8. Kilinckaya MF, Yucel Ç, Turhan T. An evaluation of efficiency in an emergency laboratory by turnaround time. Int J Med Biochem. 2018;1:57-61.
  9. Novis DA, Jones BA, Dale JC, Walsh MK; College of American Pathologists. Biochemical markers of myocardial injury test turnaround time: a College of American Pathologists Q-Probes study of 7020 troponin and 4368 creatine kinase-MB determinations in 159 institutions. Arch Pathol Lab Med. 2004;1282:158-164.
  10. Chien TI, Lu JY, Kao JT, Cheng YC, Lee YF. Evaluation and improvement strategy of analytical turnaround time in the stat laboratory. J Formos Med Assoc. 2007;1067:558-564.

Kaynak Göster

APA
Öztürk, A., & Demirci, G. (2023). Determining the turnaround time in a newly established biochemistry laboratory. Archives of Current Medical Research, 4(3), 153-177. https://doi.org/10.47482/acmr.1333906
AMA
1.Öztürk A, Demirci G. Determining the turnaround time in a newly established biochemistry laboratory. Arch Curr Med Res. 2023;4(3):153-177. doi:10.47482/acmr.1333906
Chicago
Öztürk, Alpaslan, ve Gülşah Demirci. 2023. “Determining the turnaround time in a newly established biochemistry laboratory”. Archives of Current Medical Research 4 (3): 153-77. https://doi.org/10.47482/acmr.1333906.
EndNote
Öztürk A, Demirci G (01 Eylül 2023) Determining the turnaround time in a newly established biochemistry laboratory. Archives of Current Medical Research 4 3 153–177.
IEEE
[1]A. Öztürk ve G. Demirci, “Determining the turnaround time in a newly established biochemistry laboratory”, Arch Curr Med Res, c. 4, sy 3, ss. 153–177, Eyl. 2023, doi: 10.47482/acmr.1333906.
ISNAD
Öztürk, Alpaslan - Demirci, Gülşah. “Determining the turnaround time in a newly established biochemistry laboratory”. Archives of Current Medical Research 4/3 (01 Eylül 2023): 153-177. https://doi.org/10.47482/acmr.1333906.
JAMA
1.Öztürk A, Demirci G. Determining the turnaround time in a newly established biochemistry laboratory. Arch Curr Med Res. 2023;4:153–177.
MLA
Öztürk, Alpaslan, ve Gülşah Demirci. “Determining the turnaround time in a newly established biochemistry laboratory”. Archives of Current Medical Research, c. 4, sy 3, Eylül 2023, ss. 153-77, doi:10.47482/acmr.1333906.
Vancouver
1.Alpaslan Öztürk, Gülşah Demirci. Determining the turnaround time in a newly established biochemistry laboratory. Arch Curr Med Res. 01 Eylül 2023;4(3):153-77. doi:10.47482/acmr.1333906