İMPLANT ÜSTÜ GELENEKSEL ÖLÇÜ YÖNTEM, TEKNİK ve MALZEMELERİNİN KARŞILAŞTIRMALI OLARAK GÖZDEN GEÇİRİLMESİ: SİSTEMATİK BİR GÜNCELLEME
Öz
Anahtar Kelimeler
Kaynakça
- 1. Layla Assila ve ark, İmpression Techniques For İmplant Dentistry (part1):closed tray technique. 2018. Int. J. Adv. Res. 6(12): 1249- 1252. 2. Alikhasi M., Siadat H., Monzavi A., Momen- Heravi F. Three-Dimensional accuracy of implant and abutment level impression techniques: Effect of marginal discrepancy. Journal of Oral Implantology, 2011; 6: 649- 657. 3.Prithviraj DR, Pujari ML, Garg P., Shruthi DP. Accuracy of the implant impression obtained from different impression materials and techniques: review. J Clin Exp Dent. 2011; 3(2): e106-111. 4.Balouch F., Jalalian E., Nikkheslat M., Ghavamian R., Toopchi Sh., Jallalian F., Jalalian S. Comparison of Dimensional Accuracy between Open-Tray and Closed- Tray Implant Impression Technique for 15° Angle Implants. J Dent Shiraz Univ Med Sci, Sept. 2013; 14(3): 96-102. 5.Chee W., Jivraj S. Impression techniques for implant dentistry. British Dental Journal 2006; 201: 429-432 6.Shankar YR., Sahoo S., Krishna MH., Kumar PS., Kumar TS., Narula S. Accuracy of implant impressions using various impression techniques and impression materials. J Dent Implant 2016; 6: 29-36. 7. Lee H., Joseph S. So, Hochstedler JL., Ercoli C. The accuracy of implant impressions: A systematic review. Prosthet Dent. 2008; 100: 285-291. 8.Baig M.R. Multi-unit implant impression accuracy: A review of the literature. Quintessence Int 2014; 45: 39-51. 9. Maria menini ve ark .«Accuracy of multi –unit implant impression: technique versus a digital procedure. J Prosthet. 2018 Apr; 22(3): 1253-1262. 10. Accuracyofmulti-unitimplantimpression: traditionaltechniques versus a digital procedure Clin Oral Invest, 2018, 22: 1253-1262. 11. Lee H., So JS., Hochstedler JL., Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent, 2008, 100: 285-291. 12. Baig MR. Accuracy of impressions of multiple implants in the edentulous arch: a systematic review. Int J Oral Maxillofac Implants, 2004, 29: 869-880. 13. De La Cruz JE,, Funkenbusch PD,, Ercoli C,, Moss ME,, Graser GN,, Tallents RH. (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent, 88: 329-336. 14. Naconecy MM., Teixeira ER., Shinkai RS., Frasca LC., Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac Implants. 2004, 19: 192- 198. 15. Burawi G., Houston F., Byrne D., Claffey N. A comparisonof the dimensional accuracy ofthesplinted andunsplintedimpression techniques for the Bone-Lockimplant system. J Prosthet Dent, 1997, 77: 68-75. 16. Keul C., Stawarczyk B., Erdelt KJ., Beuer F., Edelhoff D., Güth JF. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater, 2014, 30: 400-407. 17. Keul C., Stawarczyk B., Erdelt KJ., Beuer F., Edelhoff D., Güth JF. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater, 2014 30: 400-407. 18. Syrek A., Reich G., Ranftl D., Klein C., Cerny B., Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent, 2010, 38: 553-559. 19. Joda T., Katsoulis J., Brägger U. Clinical fitting and adjustmenttimeforimplant-suppor tedcrownscomparingdigitalandconventional workflows. Clin Implant Dent Relat Res. 2015. https://doi.org/ 10.1111/cid.12377. 20. Hüseyin Aktöre ve ark. The evaluation of factors that affect the accuracy of implant impressions. J Cumuryet dental. 2014 available at. http://dergipark.ulakbim.gov.tr/ cumudj/21.20 Pandita A, Jain T, Yadav NS, Feroz SM,Pradeep, Diwedi A. Evaluation and comparison of dimensional accuracy of newly introduced elastomeric impression material using 3D laser scanners: an in vitro study. J Contemp Dent Pract, 2013; 14: 265-268. 21. Carr AB. Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992;7: 468-475. 22. Jo SH, Kim KI, Seo JM, Song KY, Park JM, Ahn SG. Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study. J Adv Prosthodont 2010;2:128-133. 23. Reddy S, Prasad K, Vakil H, Jain A, Chowdhary R. Accuracy of impressions with different impression materials in angulated implants. Niger J Clin Pract 2013;16: 279-284. 24. Assuncao WG, Cardoso A, Gomes EA, Tabata LF, dos Santos PH. Accuracy of impression techniques for implants. Part 1--Influence of transfer copings surface abrasion. J Prosthodont 2008;17: 641-647. 25. Mostafa TMN, Elgendy MNM, Kashef NA, Halim MM. Evaluation of the precision of three implant transfer impression techniques using two elastomeric impression materials. Int J Prosthodont 2010; 23: 525-528. 26. Lee SJ, Macarthur RX 4th, Gallucci GO. An evaluation of student and clinician perception of digital and conventional implant impressions. J Prosthet Dent 2013; 110: 420- 423. 27. Reddy S, Prasad K, Vakil H, Jain A, Chowdhary R. Accuracy of impressions with different impression materials in angulated implants. Niger J Clin Pract 2013; 16 :279-284. 28.Vigolo P, Majzoub Z, Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003; 89: 186-192. 29. Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004; 19: 192- 198. 30. Lorenzoni M, Pertl C, Penkner K, Polansky R, Sedaj B, Wegscheider WA. Comparison of the transfer precision of three different impression materials incombination with transfer caps for the Frialit-2 system. J Oral Rehabil 2000; 27: 629-638. 31. Assuncao WG, Cardoso A, Gomes EA, Tabata LF, dos Santos PH. Accuracy of impression techniques for implants. Part 1--Influence of transfer copings. 32.Conrad HJ, Pesun IJ, Delong R, Hodges JS. Accuracy of two impression techniques with angulated implants. J Prosthet Dent 2007; 97: 349-356. 33.Gayathridevi S.K, Harshita G.,Vaishali K., Suma. Impression Techniques in Implants. Journal of Dental & Oro-facial Research Vol 12 Issue 02 Aug 2016. 34.Alexander Schmidt ve ark. accuracy of various impression materialis and for two implant systems. 2018 Apr; 62(2): 245-251. 35.W. Engelke, O.A. Decco, A.C. Cura, I. Maldonado, F.G. CrippaInfluence of implant diameter in the displacement of dental implants in trabecular bovine bone under a static lateral load: experimental results and computational modelingImplant Dent, 23(2014): 635-640. 36. Ece, Şengül ve ark. impression techniques used in implant-supported prosthesis: a review. 2015; 13 (2): 37-43. 37. Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990; 5: 331. 38. De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH. Verification jigs made of different materials. J Prosthet Dent 2002; 88: 329-336. 39. Phillips KM, Nicholls JI, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three-dimensional analysis. Int J Oral Maxillofac Implants 1994; 9: 533-540. 40. Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. İmplant Dentistry 2004; 13: 358-364. 41. Selecman AM, Wicks RA. Making an implant-level impression using solid plastik, pres-fit, closed-tray impression copings: a clinical report. J Prosthet Dent. 2009; 101: 158-159. 42.Phillips KM, Nicholls JI, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three-dimensional analysis. Int J Oral Maxillofac Implants 1994, s: 53340. 44. Craig RG, Powers JM. Restorative Dental Materials. 11th ed. St. Louis: Mosby; 2002 45. Jo SH, Kim KI, Seo JM, Song KY, Park JM, Ahn SG. Effect of impression coping and implant angulation on the accuracy of implant impressions: An in vitro study. J Adv Prosthodont 2010; 2: 128-133. 46. Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: A systematic review. J Prosthet Dent 2008; 100: 285-291. 47. Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000; 83: 323-331. 48. Al Quran FA, Rashdan BA, Zomar AA, Weiner S. Passive fit and accuracy of three dental implant impression techniques. Quintessence Int 2012; 43: 119-125. 49. Kim S, Nicholls JI, Han CH, Lee KW. Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 2006; 21: 747-755. 50. Akalin ZF, Ozkan YK, Ekerim A. Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy. Int J Oral Maxillofac Implants 2013; 28: 149-157. 52. D’Arcangelo C, Zarow M, De Angelis F, VadiniM, Paolantonio M, Giannoni M, D’Amario M.Five-year retrospective clinical study of indirectcomposite restorations luted with a light-curedcomposite in posterior teeth. Clin Oral Investig.18(2):615-24 (2014). 53. D’arcangelo C, De Angelis F, Vadini M,D’Amario M. Clinical evaluation on porcelainlaminate veneers bonded with lightcuredcomposite: results up to 7 years. Clinical oral investigations. 16(4):1071-9 (2012). 54.Herfort TW, Gerberich WW, Macosko CW, Goodkind RJ. Tear strength of elastomeric mpression materials J Prosthet Dent. 39(1):59- 62: (1978). 55. Al-Kaisy N. A Survey of Prosthodontics Techniques Applied by Dental Practitioners in Sulaimani City. J Bagh Coll Dentistry; 28(3):22-29) (2016). 56. Reddy GV, Reddy NS, Itttigi J, Jagadeesh KN. A comparative study to determine the wettabilityand castability of different elastomeric impressionmaterials. J Contemp Dent Pract. 13(3):356-63(2012 ). 57. Filho HG, Mazaro JVQ, Vedovatto E, Assunçao WG, dos Santos PH. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques. J Prosthodont 2009;18:172-176. 58. Buzayan M, Baig MR, Yunus N. Evaluation of accuracy of completearch multiple-unit abutment-level dental implant impressions using different impression and splinting materials. Int J Oral Maxillofac Implants 2013;28:1512-1520. 59.Sorrentino R, Gherlone EF, Calesini G, Zarone F. Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitrocomparative study. Clin Implant Dent Relat Res 2010;12:63-76 60.Petrie, CS, Walker, MP, O’Mahony, AM, andSpencer, P. Dimensional accuracy and surfacedetail reproduction of two hydrophilic vinylpolysiloxane impression materials tested underdry, moist, and wet conditions. J ProsthetDent.; 90: 365–372 (2003). 61. Kess RS, Combe EC, Sparks BS. Effect ofsurface treatments on the wettability of vinyl polysiloxane impression materials. J ProsthetDent. 84(1):98-102 (2000). 62. Nassar U1, Oko A, Adeeb S, El-Rich M, Flores-Mir C. An in vitro study on the dimensionalstability of a vinyl polyether silicone impressionmaterial over a prolonged storage period. JProsthet Dent. 109(3):172-8. 63. Pandita A1, Jain T, Yadav NS, Feroz SM, Pradeep, Diwedi A. Evaluation and comparison of dimensional accuracy of newly introducedelastomeric impression material using 3D laser scanners: an in vitro study. J Contemp DentMohammed et al. Biomed. & Pharmacol. J, Vol. 11(3), 1359-1368 (2018) 1367Pract. 14(2):265-8 (2013). 64. Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant-supported superstructures. J Prosthet Dent 2000;83:555- 61. 65. Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A. Evaluation of the accuracy of 3 transfer techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac. Implants 2004;19:192-8.
Ayrıntılar
Birincil Dil
Türkçe
Konular
Sağlık Kurumları Yönetimi
Bölüm
Derleme
Yazarlar
Ailimu Mirebani
*
Bu kişi benim
Türkiye
Lamia Najafova
Bu kişi benim
Türkiye
Tuğrul Sarı
Bu kişi benim
Türkiye
Hüseyin Kurtulmuş
Bu kişi benim
Türkiye
Yayımlanma Tarihi
1 Nisan 2019
Gönderilme Tarihi
5 Ekim 2018
Kabul Tarihi
30 Mart 2019
Yayımlandığı Sayı
Yıl 2019 Cilt: 5 Sayı: 1