Araştırma Makalesi

M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide

Cilt: 9 Sayı: 2 30 Aralık 2019
PDF İndir
EN TR

M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide

Öz

In this study, Mβα X-ray production cross-sections and average M-shell fluorescence yields were determined by using EDXRF at 5.96 keV for Pt, Au and Tl compounds. The photo-peak areas were used for the measurement of M X-ray production cross-sections and also other parameters. The obtained values were compared with the theoretical values in the literature to explain the changes in parameters. It was obtained that the changes were resulted from the electronegativity differences between Pt, Br and O in Pt compounds and Au, Br and O in Au compounds. As for Tl compounds, it was obtained different results and attributed to both of the charge transfer from one element to another and polarizability mechanisms of Tl.

Anahtar Kelimeler

Kaynakça

  1. [1] Aylikci, N.K., Aylikci, V., Kahoul, A., Tirasoglu, E., Karahan, I.H., Cengiz, E., Effect of pH treatment on K-shell X-ray intensity ratios and K-shell X-ray production cross-sections in ZnCo alloys, Physical Review A, 84, 042509, 2011.
  2. [2] Yang, Y., Structural and dynamical properties of water adsorption on PtO2(001), RSC. Advances, 8, 15078-15086, 2018.
  3. [3] Tanzer, K., Pelc, A., Huber, S.E., Smialek, M.A., Scheier, P., Probst, M., Denifl, S., Low energy electron attachment to platinum (II) bromide, International Journal of Mass Spectrometry, 365-366, 152-156, 2014.
  4. [4] Shi, H., Asahi, R., Stampfl, C., Properties of the gold oxides Au2O3 and Au2O: First principle investigation, Physical Review B, 75, 205125, 2007.
  5. [5] Kwon, C.K., Kim, B.J., Lee, J.L., Kim, S.Y., Effect of anions in Au complexes on doping and degredation of graphene, Journal of Materials Chemistry C, 1, 2463-2469, 2013.
  6. [6] Ertugrul, M., Sade, K., Erdogan, H., Calculation of M x-ray production cross sections from 1–1500 keV in the atomic region 70≤Z≤92, X-ray Spectrometry, 33, 136-145, 2004.
  7. [7] Ertugrul, M., Tirasoglu, E., Kurucu, Y., Erzenoglu, S., Durak, R., Sahin, Y., Measurement of M shell X-ray production cross-sections and fluorescence yields for the elements in the atomic range 70≤Z≤92 at 5.96 keV, Nuclear Instruments and Methods in Physics Research Section B, 108, 18-22, 1996.
  8. [8] Puri, S., Mehta, D., Chand, B., Singh, N., Mangal, P.C., Trehan, P.N., M shell X-ray production cross sections and fluorescence yields for the elements with 71≤Z≤92 using 5.96 keV photons, Nuclear Instruments and Methods in Physics Research Section B, 73, 319-323, 1993.

Ayrıntılar

Birincil Dil

İngilizce

Konular

İnorganik Kimya

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Aralık 2019

Gönderilme Tarihi

25 Ocak 2019

Kabul Tarihi

18 Aralık 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 9 Sayı: 2

Kaynak Göster

APA
Küp Aylıkcı, N., Aylıkcı, V., Tıraşoğlu, E., & Depci, T. (2019). M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide. Adıyaman University Journal of Science, 9(2), 274-289. https://doi.org/10.37094/adyujsci.517880
AMA
1.Küp Aylıkcı N, Aylıkcı V, Tıraşoğlu E, Depci T. M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide. ADYU J SCI. 2019;9(2):274-289. doi:10.37094/adyujsci.517880
Chicago
Küp Aylıkcı, Nuray, Volkan Aylıkcı, Engin Tıraşoğlu, ve Tolga Depci. 2019. “M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide”. Adıyaman University Journal of Science 9 (2): 274-89. https://doi.org/10.37094/adyujsci.517880.
EndNote
Küp Aylıkcı N, Aylıkcı V, Tıraşoğlu E, Depci T (01 Aralık 2019) M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide. Adıyaman University Journal of Science 9 2 274–289.
IEEE
[1]N. Küp Aylıkcı, V. Aylıkcı, E. Tıraşoğlu, ve T. Depci, “M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide”, ADYU J SCI, c. 9, sy 2, ss. 274–289, Ara. 2019, doi: 10.37094/adyujsci.517880.
ISNAD
Küp Aylıkcı, Nuray - Aylıkcı, Volkan - Tıraşoğlu, Engin - Depci, Tolga. “M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide”. Adıyaman University Journal of Science 9/2 (01 Aralık 2019): 274-289. https://doi.org/10.37094/adyujsci.517880.
JAMA
1.Küp Aylıkcı N, Aylıkcı V, Tıraşoğlu E, Depci T. M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide. ADYU J SCI. 2019;9:274–289.
MLA
Küp Aylıkcı, Nuray, vd. “M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide”. Adıyaman University Journal of Science, c. 9, sy 2, Aralık 2019, ss. 274-89, doi:10.37094/adyujsci.517880.
Vancouver
1.Nuray Küp Aylıkcı, Volkan Aylıkcı, Engin Tıraşoğlu, Tolga Depci. M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide. ADYU J SCI. 01 Aralık 2019;9(2):274-89. doi:10.37094/adyujsci.517880