Loss of strength in foot dorsiflexors, gravity, and the effect of plantar flexor lead to keep the foot in plantar flexion, and thus not to dorsiflexion. This condition is called drop foot deformity. Drop foot is symptom of many diseases and cause a non-aesthetic walk, fall and injury. The most common cause of drop foot is peroneal nerve injury.Ankle-foot orthoses AFO is useful in the treatment extensor muscle paralysis of leg. Carbon graphite AFO, thin base design and open-heel structure allows for comfortable use shoes with all kind s of. Lightweight carbon-fiber structure and the medial and lateral shafts increases the motion ability of patients of high level of activation. The aim of this study in a drop-foot patient to to emphasize Carbon Graphite AFO that the positive effects on the balance and the functional ambulation activities
1. Uygur, F. Ayak Deformite ve Ortezleri. Hacettepe
Üniversitesi Fizik Tedavi ve Rehabilitasyon
Yüksekokulu Yayınları. Ankara: Volkan
Matbaacılık 1992.
2. Bielecki M, Zebrowski P, Kuryliszyn-Moskal A.
Treatment of foot drop in orthopaedic practice.
Wiad Lek. 2012; 65(2): 132-7.
3. Wolf S, Alimusaj M, Rettig O, Döderlein L.
Dynamic assist by carbon fiber spring AFOs for
patients with myelomeningocele. Gait Posture 2008;
(28): 175–7.
4. Miyazaki S, Yamamoto S, Kubota T. Effect of
ankle-foot orthosis on active ankle moment in
patients with hemiparesis. Med Biol Eng Comput
1997; 35(4): 381–5.
5. Nester CJ, van der Linden ML, Bowker P. Effect of
foot orthoses on the kinematics and kinetics of
normal walking gait. Gait Posture 2003; 17(2): 180–
7.
6. Ounpuu S, Bell KJ, Davis III RB, DeLuca PA. An
evaluation of the posterior leaf spring orthosis using
joint kinematics and kinetics. J Pediatr Orthop 1996;
16(3): 378–84.
Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi
Ayak dorsifleksörlerinin kuvvet kaybı, yerçekimi ve plantar fleksörlerin etkisi ile ayağın plantar fleksiyonda kalmasına; dolayısı ile dorsifleksiyon yapamamasına yol açar. Bu durum düşük ayak deformitesi olarak adlandırılır. Düşük ayak pek çok hastalığın semptomudur ve estetik olmayan bir yürüyüşe, düşmeye ve yaralanmalara yol açar. Düşük ayağın en yaygın nedeni peroneal sinir yaralanmasıdır. Ayakayak bileği ortezleri AFO ayağın ekstansör kas paralizisi tedavisinde faydalıdır. Karbon Grafit AFO, ince taban dizaynı ve açık topuk yapısı sayesinde her türlü ayakkabı ile rahat kullanım imkanı sağlar. Hafif karbon fiber yapısı ile medial ve lateral milleri, aktivasyon seviyesi yüksek hastaların hareket kabiliyetini arttırır. Bu çalışmanın amacı düşük ayaklı bir olguda Karbon Grafit AFO’nun fonksiyonel ambulasyon aktiviteleri ve denge üzerine olumlu etkileri olduğunu vurgulamaktır
1. Uygur, F. Ayak Deformite ve Ortezleri. Hacettepe
Üniversitesi Fizik Tedavi ve Rehabilitasyon
Yüksekokulu Yayınları. Ankara: Volkan
Matbaacılık 1992.
2. Bielecki M, Zebrowski P, Kuryliszyn-Moskal A.
Treatment of foot drop in orthopaedic practice.
Wiad Lek. 2012; 65(2): 132-7.
3. Wolf S, Alimusaj M, Rettig O, Döderlein L.
Dynamic assist by carbon fiber spring AFOs for
patients with myelomeningocele. Gait Posture 2008;
(28): 175–7.
4. Miyazaki S, Yamamoto S, Kubota T. Effect of
ankle-foot orthosis on active ankle moment in
patients with hemiparesis. Med Biol Eng Comput
1997; 35(4): 381–5.
5. Nester CJ, van der Linden ML, Bowker P. Effect of
foot orthoses on the kinematics and kinetics of
normal walking gait. Gait Posture 2003; 17(2): 180–
7.
6. Ounpuu S, Bell KJ, Davis III RB, DeLuca PA. An
evaluation of the posterior leaf spring orthosis using
joint kinematics and kinetics. J Pediatr Orthop 1996;
16(3): 378–84.
Talu, B. (2014). Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi. Annals of Health Sciences Research, 3(2), 24-25.
AMA
Talu B. Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi. Ann Health Sci Res. Ekim 2014;3(2):24-25.
Chicago
Talu, Burcu. “Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri Ve Denge Üzerine Etkisinin Değerlendirilmesi”. Annals of Health Sciences Research 3, sy. 2 (Ekim 2014): 24-25.
EndNote
Talu B (01 Ekim 2014) Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi. Annals of Health Sciences Research 3 2 24–25.
IEEE
B. Talu, “Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi”, Ann Health Sci Res, c. 3, sy. 2, ss. 24–25, 2014.
ISNAD
Talu, Burcu. “Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri Ve Denge Üzerine Etkisinin Değerlendirilmesi”. Annals of Health Sciences Research 3/2 (Ekim 2014), 24-25.
JAMA
Talu B. Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi. Ann Health Sci Res. 2014;3:24–25.
MLA
Talu, Burcu. “Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri Ve Denge Üzerine Etkisinin Değerlendirilmesi”. Annals of Health Sciences Research, c. 3, sy. 2, 2014, ss. 24-25.
Vancouver
Talu B. Düşük Ayaklı Bir Olguda Karbon Grafit AFO Kullanımının Fonksiyonel Ambulasyon Aktiviteleri ve Denge Üzerine Etkisinin Değerlendirilmesi. Ann Health Sci Res. 2014;3(2):24-5.