Radiographic analysis of the kinematic total knee replacement

Cilt: 25 Sayı: 5 11 Eylül 2006
  • Sefa Muezzinoglu
  • Mumtaz Alpaslan
  • Adil Surat
  • Mahmut Doral
PDF İndir
EN TR

Radiographic analysis of the kinematic total knee replacement

Öz

Technical perfection of alignment and component position are the goals of the total knee arthroplasty. Early analysis of 41 kinematic total knee replacement was made. Surgical technique is produced on the basis of the principles of Hungerford and associates. Tibial cutting guide is always in 9 degrees varus. The femoral cutting guide can be adjusted to three different angles which are 7, 9 and 11 degre Radiografphic analysis was done after operation for each knee. The difference between the expected and assesed value, were determined. For femoral side the errors were prominently in the varus direction. Statistical analysis of the varus errors in the angle alpha is meaningfull and the average of varus errors is 3. 54 degrees 3 degrees must be added to angle a and the nearest degree in the cutting guide must be chosen. In the tibial component erros were equal on each side. This may depend on extramedullary tibial alignment guide. Long term results depend on the correct application of the compontents. it seemed that preoperative measurements and careful planning were extremely important.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Sefa Muezzinoglu Bu kişi benim

Mumtaz Alpaslan Bu kişi benim

Adil Surat Bu kişi benim

Mahmut Doral Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1991 Cilt: 25 Sayı: 5

Kaynak Göster

APA
Muezzinoglu, S., Alpaslan, M., Surat, A., & Doral, M. (2006). Radiographic analysis of the kinematic total knee replacement. Acta Orthopaedica et Traumatologica Turcica, 25(5), 358-359. https://doi.org/10.3944/aott.v25i5.1264
AMA
1.Muezzinoglu S, Alpaslan M, Surat A, Doral M. Radiographic analysis of the kinematic total knee replacement. Acta Orthopaedica et Traumatologica Turcica. 2006;25(5):358-359. doi:10.3944/aott.v25i5.1264
Chicago
Muezzinoglu, Sefa, Mumtaz Alpaslan, Adil Surat, ve Mahmut Doral. 2006. “Radiographic analysis of the kinematic total knee replacement”. Acta Orthopaedica et Traumatologica Turcica 25 (5): 358-59. https://doi.org/10.3944/aott.v25i5.1264.
EndNote
Muezzinoglu S, Alpaslan M, Surat A, Doral M (01 Eylül 2006) Radiographic analysis of the kinematic total knee replacement. Acta Orthopaedica et Traumatologica Turcica 25 5 358–359.
IEEE
[1]S. Muezzinoglu, M. Alpaslan, A. Surat, ve M. Doral, “Radiographic analysis of the kinematic total knee replacement”, Acta Orthopaedica et Traumatologica Turcica, c. 25, sy 5, ss. 358–359, Eyl. 2006, doi: 10.3944/aott.v25i5.1264.
ISNAD
Muezzinoglu, Sefa - Alpaslan, Mumtaz - Surat, Adil - Doral, Mahmut. “Radiographic analysis of the kinematic total knee replacement”. Acta Orthopaedica et Traumatologica Turcica 25/5 (01 Eylül 2006): 358-359. https://doi.org/10.3944/aott.v25i5.1264.
JAMA
1.Muezzinoglu S, Alpaslan M, Surat A, Doral M. Radiographic analysis of the kinematic total knee replacement. Acta Orthopaedica et Traumatologica Turcica. 2006;25:358–359.
MLA
Muezzinoglu, Sefa, vd. “Radiographic analysis of the kinematic total knee replacement”. Acta Orthopaedica et Traumatologica Turcica, c. 25, sy 5, Eylül 2006, ss. 358-9, doi:10.3944/aott.v25i5.1264.
Vancouver
1.Sefa Muezzinoglu, Mumtaz Alpaslan, Adil Surat, Mahmut Doral. Radiographic analysis of the kinematic total knee replacement. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;25(5):358-9. doi:10.3944/aott.v25i5.1264