EN
TR
Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus
Abstract
In this study, Universtiy of California Biomechanics Laboratory (UCBL) inserts were applied to fifthteen patients diagnosed with severe flexide pes planus to evaluate the effectiveness of this inserts to the orter type of shoe modifications. For this perpause, clinically observed patients, were reevaluated (balance, gait promIems and pain) while they jwere standing and walking with their UCBL inserts. After the UCBL inserts have been utilised by the patients for three months, patients were walked on the mechanical treadmill until they had the feeling of tiredness to evaluate their duration of walking and double product values which were one of the criterias of walking and double product values which were one of the criterias of energy expenditure of the body. To understand the effectiveness of the UCBL inserts in achieving the normal anatomical position of the foot, plantar flexion angle of talus and calcaneal pitch were observed on X-ray radiograms of each patient in both conditions. The collected data were analysed with statistical methods. According to our results, in a fixed time, patients were able to walk clinically much more efficient and with a Iesser energy expenditure while they were having UCBL inserts.
Keywords
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
11 Eylül 2006
Gönderilme Tarihi
6 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 1994 Cilt: 28 Sayı: 1
APA
Inal, S., Bursali, A., & Gokcay, İ. (2006). Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus. Acta Orthopaedica et Traumatologica Turcica, 28(1), 42-46. https://doi.org/10.3944/aott.v28i1.1453
AMA
1.Inal S, Bursali A, Gokcay İ. Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus. Acta Orthopaedica et Traumatologica Turcica. 2006;28(1):42-46. doi:10.3944/aott.v28i1.1453
Chicago
Inal, Serap, Aysegul Bursali, ve İrfan Gokcay. 2006. “Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus”. Acta Orthopaedica et Traumatologica Turcica 28 (1): 42-46. https://doi.org/10.3944/aott.v28i1.1453.
EndNote
Inal S, Bursali A, Gokcay İ (01 Eylül 2006) Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus. Acta Orthopaedica et Traumatologica Turcica 28 1 42–46.
IEEE
[1]S. Inal, A. Bursali, ve İ. Gokcay, “Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus”, Acta Orthopaedica et Traumatologica Turcica, c. 28, sy 1, ss. 42–46, Eyl. 2006, doi: 10.3944/aott.v28i1.1453.
ISNAD
Inal, Serap - Bursali, Aysegul - Gokcay, İrfan. “Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus”. Acta Orthopaedica et Traumatologica Turcica 28/1 (01 Eylül 2006): 42-46. https://doi.org/10.3944/aott.v28i1.1453.
JAMA
1.Inal S, Bursali A, Gokcay İ. Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus. Acta Orthopaedica et Traumatologica Turcica. 2006;28:42–46.
MLA
Inal, Serap, vd. “Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus”. Acta Orthopaedica et Traumatologica Turcica, c. 28, sy 1, Eylül 2006, ss. 42-46, doi:10.3944/aott.v28i1.1453.
Vancouver
1.Serap Inal, Aysegul Bursali, İrfan Gokcay. Evulation of University of California Biomechanics Laboratory inserts in the treatment of severe flexible pes planus. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;28(1):42-6. doi:10.3944/aott.v28i1.1453