BibTex RIS Kaynak Göster

The quantitative comparison of measurements in rachitic and normal children's hip radiogram and importance of AU line

Yıl 1996, Cilt: 30 Sayı: 3, 269 - 272, 11.09.2006
https://izlik.org/JA87KG53SZ

Öz

Hilgenreiner's height (H) and distance (D) as well as AU line length were measured on the pelvic roentgenograms of 90 children (5-12 months old) of which 50 were normal and 40 rachitic. The relationship between AU line and epiphyses of femoral head was also investigated. We found a highly significant difference between measurements of normal and rachitic children (p<0.001). It was seen that, the relations of AU line with epiphyses of femoral head were important among differential diagnosis criteria.

Normal ve raşitizmli çocukların kalça radyografilerinde ölçümlerin kantitatif değerlerinin karşılaştırılması ve AU çizgisinin önemi

Yıl 1996, Cilt: 30 Sayı: 3, 269 - 272, 11.09.2006
https://izlik.org/JA87KG53SZ

Öz

Bu çalışmada 5-12 aylık (50 normal ve 40 raşitik olmak üzere) toplam 90 çocuğun 180 kalçasının ön-arka filmleri üzerinde Hilgenreiner’in h yüksekliği ve d mesafesi ölçüldü. Ayrıca AU çizgisi ölçümleri ve bu çizginin femur başı epifiz çekirdeği (FBEÇ) ile ilişkileri araştırıldı. Normal çocuklarda raşitik çocukların bu ölçüm sonuçları arasında anlamlı derecede fark olduğu (p<0.001) tesbit edildi. AU çizgisi ite FBEÇ ilişkilerinin normal kalçalar ile raşitik arasında bir ayırıcı tanı kriteri olarak önem arzettiği görüldü.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Yazarlar

Fuat Akpinar Bu kişi benim

Nihat Tosun Bu kişi benim

Cihangir Islam Bu kişi benim

Halil Aslan Bu kişi benim

A. Oner Bu kişi benim

Atif Aydinlioglu Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
DOI https://doi.org/10.3944/aott.v30i3.1990
IZ https://izlik.org/JA87KG53SZ
Yayımlandığı Sayı Yıl 1996 Cilt: 30 Sayı: 3

Kaynak Göster

APA Akpinar, F., Tosun, N., Islam, C., Aslan, H., Oner, A., & Aydinlioglu, A. (2006). The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line. Acta Orthopaedica et Traumatologica Turcica, 30(3), 269-272. https://doi.org/10.3944/aott.v30i3.1990
AMA 1.Akpinar F, Tosun N, Islam C, Aslan H, Oner A, Aydinlioglu A. The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line. Acta Orthopaedica et Traumatologica Turcica. 2006;30(3):269-272. doi:10.3944/aott.v30i3.1990
Chicago Akpinar, Fuat, Nihat Tosun, Cihangir Islam, Halil Aslan, A. Oner, ve Atif Aydinlioglu. 2006. “The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line”. Acta Orthopaedica et Traumatologica Turcica 30 (3): 269-72. https://doi.org/10.3944/aott.v30i3.1990.
EndNote Akpinar F, Tosun N, Islam C, Aslan H, Oner A, Aydinlioglu A (01 Eylül 2006) The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line. Acta Orthopaedica et Traumatologica Turcica 30 3 269–272.
IEEE [1]F. Akpinar, N. Tosun, C. Islam, H. Aslan, A. Oner, ve A. Aydinlioglu, “The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line”, Acta Orthopaedica et Traumatologica Turcica, c. 30, sy 3, ss. 269–272, Eyl. 2006, doi: 10.3944/aott.v30i3.1990.
ISNAD Akpinar, Fuat - Tosun, Nihat - Islam, Cihangir - Aslan, Halil - Oner, A. - Aydinlioglu, Atif. “The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line”. Acta Orthopaedica et Traumatologica Turcica 30/3 (01 Eylül 2006): 269-272. https://doi.org/10.3944/aott.v30i3.1990.
JAMA 1.Akpinar F, Tosun N, Islam C, Aslan H, Oner A, Aydinlioglu A. The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line. Acta Orthopaedica et Traumatologica Turcica. 2006;30:269–272.
MLA Akpinar, Fuat, vd. “The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line”. Acta Orthopaedica et Traumatologica Turcica, c. 30, sy 3, Eylül 2006, ss. 269-72, doi:10.3944/aott.v30i3.1990.
Vancouver 1.Akpinar F, Tosun N, Islam C, Aslan H, Oner A, Aydinlioglu A. The quantitative comparison of measurements in rachitic and normal children’s hip radiogram and importance of AU line. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Eylül 2006;30(3):269-72. Erişim adresi: https://izlik.org/JA87KG53SZ