Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)

Cilt: 32 Sayı: 4 11 Eylül 2006
  • Ercan Olcay
  • Turgut Gulmez
  • Cem Esenyel
  • Bulent Aksoy
  • Omer Yildirim
  • Murat Bulbul
PDF İndir
EN TR

Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)

Abstract

Extraarticular displaced distal radius fractures were created on the forearms of the 28 embalmed cadevers. Four kinds of configurations of stabilizations were performed by using 4,3,2, and 1 Kirschner wires.Stabilization tests were done by using the 600 kN Universal Testing Machine of the Servo-Hydraulic type named Dartec.A force was applied and displacement at the fracture sides measured.Results were evaluated statistically.The samples which were stabilized by one Kirschner wire were detected to be unstable.The ones which were stabilized by two crossed Kirschner wires were consistently stable.When three and four Kirschner wires were used it was noticed that more rigid stabilization was achieved;But the results were not significantly different from the samples which 2 Kirschner wires were used. In conclusion,when minimum of 2 Kirschner wires were used for the fixation of the displaced extraarticular distal fractures of the radius,an adequate and safe stabilizaton could be achieved.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Ercan Olcay Bu kişi benim

Turgut Gulmez Bu kişi benim

Cem Esenyel Bu kişi benim

Bulent Aksoy Bu kişi benim

Omer Yildirim Bu kişi benim

Murat Bulbul Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1998 Cilt: 32 Sayı: 4

Kaynak Göster

APA
Olcay, E., Gulmez, T., Esenyel, C., Aksoy, B., Yildirim, O., & Bulbul, M. (2006). Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm). Acta Orthopaedica et Traumatologica Turcica, 32(4), 334-339. https://doi.org/10.3944/aott.v32i4.2271
AMA
1.Olcay E, Gulmez T, Esenyel C, Aksoy B, Yildirim O, Bulbul M. Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm). Acta Orthopaedica et Traumatologica Turcica. 2006;32(4):334-339. doi:10.3944/aott.v32i4.2271
Chicago
Olcay, Ercan, Turgut Gulmez, Cem Esenyel, Bulent Aksoy, Omer Yildirim, ve Murat Bulbul. 2006. “Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)”. Acta Orthopaedica et Traumatologica Turcica 32 (4): 334-39. https://doi.org/10.3944/aott.v32i4.2271.
EndNote
Olcay E, Gulmez T, Esenyel C, Aksoy B, Yildirim O, Bulbul M (01 Eylül 2006) Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm). Acta Orthopaedica et Traumatologica Turcica 32 4 334–339.
IEEE
[1]E. Olcay, T. Gulmez, C. Esenyel, B. Aksoy, O. Yildirim, ve M. Bulbul, “Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)”, Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 4, ss. 334–339, Eyl. 2006, doi: 10.3944/aott.v32i4.2271.
ISNAD
Olcay, Ercan - Gulmez, Turgut - Esenyel, Cem - Aksoy, Bulent - Yildirim, Omer - Bulbul, Murat. “Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)”. Acta Orthopaedica et Traumatologica Turcica 32/4 (01 Eylül 2006): 334-339. https://doi.org/10.3944/aott.v32i4.2271.
JAMA
1.Olcay E, Gulmez T, Esenyel C, Aksoy B, Yildirim O, Bulbul M. Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm). Acta Orthopaedica et Traumatologica Turcica. 2006;32:334–339.
MLA
Olcay, Ercan, vd. “Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm)”. Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 4, Eylül 2006, ss. 334-9, doi:10.3944/aott.v32i4.2271.
Vancouver
1.Ercan Olcay, Turgut Gulmez, Cem Esenyel, Bulent Aksoy, Omer Yildirim, Murat Bulbul. Biomechanical evaluation of the percutaneous pinning of unstable extra-articular fractures of the distal radius (A biomechanical study on an embalmed cadaver of the forearm). Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;32(4):334-9. doi:10.3944/aott.v32i4.2271