Use of electrocautery on the arthroscopic menisectomy

Cilt: 32 Sayı: 5 11 Eylül 2006
  • Hakan Ozdemir
  • Dursun Demirag
  • Merter Ozenci
  • Ahmet Aydin
PDF İndir
TR EN

Use of electrocautery on the arthroscopic menisectomy

Abstract

Electrosurgery has been used for resection of meniscal resections, lateral retinacular release, plica cutting and arthrolysis for 1980’s. From 1992 January to 1998 January, 661 arthroscopic menisectomies were performed in our clinic. In this study, we evaluated 23 electrosurgical menisectomy cases and their intraoperative and postoperative problems. Electrosurgical technique is an effective method for resection of bucket handle, longitudinal and periferal meniscal tears and discoid meniscus cases. Furthermore, complication rate of this technique is fewer than expected.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Hakan Ozdemir Bu kişi benim

Dursun Demirag Bu kişi benim

Merter Ozenci Bu kişi benim

Ahmet Aydin Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1998 Cilt: 32 Sayı: 5

Kaynak Göster

APA
Ozdemir, H., Demirag, D., Ozenci, M., & Aydin, A. (2006). Use of electrocautery on the arthroscopic menisectomy. Acta Orthopaedica et Traumatologica Turcica, 32(5), 392-394. https://doi.org/10.3944/aott.v32i5.2290
AMA
1.Ozdemir H, Demirag D, Ozenci M, Aydin A. Use of electrocautery on the arthroscopic menisectomy. Acta Orthopaedica et Traumatologica Turcica. 2006;32(5):392-394. doi:10.3944/aott.v32i5.2290
Chicago
Ozdemir, Hakan, Dursun Demirag, Merter Ozenci, ve Ahmet Aydin. 2006. “Use of electrocautery on the arthroscopic menisectomy”. Acta Orthopaedica et Traumatologica Turcica 32 (5): 392-94. https://doi.org/10.3944/aott.v32i5.2290.
EndNote
Ozdemir H, Demirag D, Ozenci M, Aydin A (01 Eylül 2006) Use of electrocautery on the arthroscopic menisectomy. Acta Orthopaedica et Traumatologica Turcica 32 5 392–394.
IEEE
[1]H. Ozdemir, D. Demirag, M. Ozenci, ve A. Aydin, “Use of electrocautery on the arthroscopic menisectomy”, Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 5, ss. 392–394, Eyl. 2006, doi: 10.3944/aott.v32i5.2290.
ISNAD
Ozdemir, Hakan - Demirag, Dursun - Ozenci, Merter - Aydin, Ahmet. “Use of electrocautery on the arthroscopic menisectomy”. Acta Orthopaedica et Traumatologica Turcica 32/5 (01 Eylül 2006): 392-394. https://doi.org/10.3944/aott.v32i5.2290.
JAMA
1.Ozdemir H, Demirag D, Ozenci M, Aydin A. Use of electrocautery on the arthroscopic menisectomy. Acta Orthopaedica et Traumatologica Turcica. 2006;32:392–394.
MLA
Ozdemir, Hakan, vd. “Use of electrocautery on the arthroscopic menisectomy”. Acta Orthopaedica et Traumatologica Turcica, c. 32, sy 5, Eylül 2006, ss. 392-4, doi:10.3944/aott.v32i5.2290.
Vancouver
1.Hakan Ozdemir, Dursun Demirag, Merter Ozenci, Ahmet Aydin. Use of electrocautery on the arthroscopic menisectomy. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;32(5):392-4. doi:10.3944/aott.v32i5.2290