Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study

Cilt: 34 Sayı: 3 11 Eylül 2006
  • Ufuk Talu
  • Ibrahim Kaya
  • Fatih Dikici
  • Cuneyt Sar
PDF İndir
EN TR

Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study

Abstract

Objectives: To investigate the effects of change in length, diameter, length and diameter on axial pull-out strengths of revisional pedicle screws and determine the best method of salvage for failed pedicle screws. Methods: We used pedilen rigid foam (equivalent to the average bone mineral density of lumbar vertebrae in cadavers as measured by quantitative computerized tomography) and Synergy pedicle screws with 1.8 mm threads. All variables but the length and diameter were kept constant during insertion of the pedicle screws. Ten different pull-out tests were performed in each of the five groups, using an Instron Model 1195 universal test machine. In the first group, screws 6.5 mm x 40 mm in size were used to draw reference values. In the remaining groups, insertion and removal of 6.5 mm x 40 mm screws was succeeded by insertion of pedicle screws of (i) the same size (6.5 mm x 40 mm), (ii) increased length (6.5 mm x 45 mm), (iii) increased diameter (7.0 mm x 40 mm), and (iv) increased length and diameter (7.0 mm x 45 mm), respectively. Pull-out strengths and load versus time curves were recorded. Results were evaluated using SPSS program and Student’s t-test. Results: The average pull-out strength decreased by 26% after substitution of the pedicle screw for one of the same size. Conversely, pull-out strengths increased by 15%, 33%, and 49% as the length, the diameter, and the length and diameter of the salvage screws increased, respectively. Differences in pull-out strengths between groups were highly significant (p<0.0001). Conclusion: Substitution of the previous pedicle screw for one of the same size would be a major mistake. Pedicle salvage using screws with increased length and diameter seems to be the most appropriate solution in restoring the strength of mechanical fixation.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Ibrahim Kaya Bu kişi benim

Fatih Dikici Bu kişi benim

Cuneyt Sar Bu kişi benim

Yayımlanma Tarihi

11 Eylül 2006

Gönderilme Tarihi

6 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2000 Cilt: 34 Sayı: 3

Kaynak Göster

APA
Talu, U., Kaya, I., Dikici, F., & Sar, C. (2006). Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica, 34(3), 300-307. https://doi.org/10.3944/aott.v34i3.1794
AMA
1.Talu U, Kaya I, Dikici F, Sar C. Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica. 2006;34(3):300-307. doi:10.3944/aott.v34i3.1794
Chicago
Talu, Ufuk, Ibrahim Kaya, Fatih Dikici, ve Cuneyt Sar. 2006. “Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica 34 (3): 300-307. https://doi.org/10.3944/aott.v34i3.1794.
EndNote
Talu U, Kaya I, Dikici F, Sar C (01 Eylül 2006) Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica 34 3 300–307.
IEEE
[1]U. Talu, I. Kaya, F. Dikici, ve C. Sar, “Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study”, Acta Orthopaedica et Traumatologica Turcica, c. 34, sy 3, ss. 300–307, Eyl. 2006, doi: 10.3944/aott.v34i3.1794.
ISNAD
Talu, Ufuk - Kaya, Ibrahim - Dikici, Fatih - Sar, Cuneyt. “Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica 34/3 (01 Eylül 2006): 300-307. https://doi.org/10.3944/aott.v34i3.1794.
JAMA
1.Talu U, Kaya I, Dikici F, Sar C. Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica. 2006;34:300–307.
MLA
Talu, Ufuk, vd. “Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study”. Acta Orthopaedica et Traumatologica Turcica, c. 34, sy 3, Eylül 2006, ss. 300-7, doi:10.3944/aott.v34i3.1794.
Vancouver
1.Ufuk Talu, Ibrahim Kaya, Fatih Dikici, Cuneyt Sar. Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study. Acta Orthopaedica et Traumatologica Turcica. 01 Eylül 2006;34(3):300-7. doi:10.3944/aott.v34i3.1794