Abstract

Objectives: This study aimed to determine the biomechanical quality of cortical bone in normal and osteoporotic rat femora with the use of biomechanical analysis and finite element analysis.
Methods : Fourteen young adult female Sprague-Dawley rats weighing 225-250 g were randomized into two groups equal in number. One group underwent bilateral ovariectomy under ketamine anesthesia. Fourteen weeks after ovariectomy, bone mineral density was measured by dual energy X–ray absorptiometry in two groups and the rats were sacrificed under high-dose ketamine anesthesia for removal of all the femora. The right femora were subjected to biomechanical tension tests. In the left femora, cortical bone sections were visualized by computed tomography and
finite element analysis was performed on computer- g e n e rated three dimensional images using the ANYSIS 9.0 software. Deformation, stress, and strain values obtained by the two analyses were compared.
Results: Compared to the control group, bone mineral density decreased by 29%, and decreases in deformation , stress, and strain values were 39%, 51%, and 64%, respectively, in the ovariectomized rats (p<0.05). No significant differences were found between the results of b i o m e c h a nical measurements and finite element analysis (p>0.05).
Conclusion: Our data suggest that finite element analysis can be used in vivo to determine biomechanical quality of the bone in osteoporotic patients.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Ulku Comelekoglu Bu kişi benim

Huseyin Mutlu Bu kişi benim

Serap Yalin Bu kişi benim

Selda Bagis Bu kişi benim

Altan Yildiz Bu kişi benim

Oya Ogenler Bu kişi benim

Yayımlanma Tarihi

18 Nisan 2007

Gönderilme Tarihi

7 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2007 Cilt: 41 Sayı: 1

Kaynak Göster

APA
Comelekoglu, U., Mutlu, H., Yalin, S., Bagis, S., Yildiz, A., & Ogenler, O. (2007). Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis. Acta Orthopaedica et Traumatologica Turcica, 41(1), 53-57. https://izlik.org/JA48HE78TE
AMA
1.Comelekoglu U, Mutlu H, Yalin S, Bagis S, Yildiz A, Ogenler O. Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis. Acta Orthopaedica et Traumatologica Turcica. 2007;41(1):53-57. https://izlik.org/JA48HE78TE
Chicago
Comelekoglu, Ulku, Huseyin Mutlu, Serap Yalin, Selda Bagis, Altan Yildiz, ve Oya Ogenler. 2007. “Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis”. Acta Orthopaedica et Traumatologica Turcica 41 (1): 53-57. https://izlik.org/JA48HE78TE.
EndNote
Comelekoglu U, Mutlu H, Yalin S, Bagis S, Yildiz A, Ogenler O (01 Nisan 2007) Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis. Acta Orthopaedica et Traumatologica Turcica 41 1 53–57.
IEEE
[1]U. Comelekoglu, H. Mutlu, S. Yalin, S. Bagis, A. Yildiz, ve O. Ogenler, “Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis”, Acta Orthopaedica et Traumatologica Turcica, c. 41, sy 1, ss. 53–57, Nis. 2007, [çevrimiçi]. Erişim adresi: https://izlik.org/JA48HE78TE
ISNAD
Comelekoglu, Ulku - Mutlu, Huseyin - Yalin, Serap - Bagis, Selda - Yildiz, Altan - Ogenler, Oya. “Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis”. Acta Orthopaedica et Traumatologica Turcica 41/1 (01 Nisan 2007): 53-57. https://izlik.org/JA48HE78TE.
JAMA
1.Comelekoglu U, Mutlu H, Yalin S, Bagis S, Yildiz A, Ogenler O. Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis. Acta Orthopaedica et Traumatologica Turcica. 2007;41:53–57.
MLA
Comelekoglu, Ulku, vd. “Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis”. Acta Orthopaedica et Traumatologica Turcica, c. 41, sy 1, Nisan 2007, ss. 53-57, https://izlik.org/JA48HE78TE.
Vancouver
1.Ulku Comelekoglu, Huseyin Mutlu, Serap Yalin, Selda Bagis, Altan Yildiz, Oya Ogenler. Determining the biomechanical quality of normal and osteoporotic bones in rat femora through biomechanical test and finite element analysis. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Nisan 2007;41(1):53-7. Erişim adresi: https://izlik.org/JA48HE78TE