Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope

Cilt: 14 Sayı: 4 21 Kasım 1980
  • Orhan Baskir
PDF İndir
EN TR

Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope

Abstract

In recent years, it has been observed that total hip endoprostheses have found an extensive field of application in the scientific branch of orthopaedics and traumatologly and that the results obtained are extremely reward promising. Yet, there seems to be certain complications arising during the late period, among which are the loosening of the acetabular and femoral components that give rise to problems. In an attempt to elucidate this problem, a study has been made in vitro on the bones obtained from the cadavers with the intention of invastigating the distribution aspects of loading prior to and after the insertion of prostheses in different position. The investigation has been effected by detecting the curve between load and crashing amount through applying bad by instron loading instrument and by examining under metallographic microscope the microstructural differeness arising after obtaining different sections at various levels. It has been concluded that the insertion of the prosthesis in the valgus position will eliminate the possibility of loosening provided that cement grasps the femoral stem of the prosthesis in every direction and the stem of the femoral component stays medially.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Orhan Baskir Bu kişi benim

Yayımlanma Tarihi

21 Kasım 1980

Gönderilme Tarihi

7 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 1980 Cilt: 14 Sayı: 4

Kaynak Göster

APA
Baskir, O. (1980). Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope. Acta Orthopaedica et Traumatologica Turcica, 14(4), 139-170. https://doi.org/10.3944/aott.v14i4.3230
AMA
1.Baskir O. Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope. Acta Orthopaedica et Traumatologica Turcica. 1980;14(4):139-170. doi:10.3944/aott.v14i4.3230
Chicago
Baskir, Orhan. 1980. “Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope”. Acta Orthopaedica et Traumatologica Turcica 14 (4): 139-70. https://doi.org/10.3944/aott.v14i4.3230.
EndNote
Baskir O (01 Kasım 1980) Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope. Acta Orthopaedica et Traumatologica Turcica 14 4 139–170.
IEEE
[1]O. Baskir, “Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope”, Acta Orthopaedica et Traumatologica Turcica, c. 14, sy 4, ss. 139–170, Kas. 1980, doi: 10.3944/aott.v14i4.3230.
ISNAD
Baskir, Orhan. “Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope”. Acta Orthopaedica et Traumatologica Turcica 14/4 (01 Kasım 1980): 139-170. https://doi.org/10.3944/aott.v14i4.3230.
JAMA
1.Baskir O. Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope. Acta Orthopaedica et Traumatologica Turcica. 1980;14:139–170.
MLA
Baskir, Orhan. “Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope”. Acta Orthopaedica et Traumatologica Turcica, c. 14, sy 4, Kasım 1980, ss. 139-70, doi:10.3944/aott.v14i4.3230.
Vancouver
1.Orhan Baskir. Loading on the femoral component by the instron instrument in total hip endoprostheses and the examination of femoral sections under metollographic microscope. Acta Orthopaedica et Traumatologica Turcica. 01 Kasım 1980;14(4):139-70. doi:10.3944/aott.v14i4.3230