Araştırma Makalesi

A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions

Cilt: 43 Sayı: 3 10 Ağustos 2009
  • Bora Bostan
  • Irfan Esenkaya
  • Taner Gunes
  • Mehmet Erdem
  • Murat Asci
  • M. Halidun Kelestemur
  • Cengiz Sen
PDF İndir
TR EN

A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions

Öz

Objectives: Different techniques and choices exist for revision of pedicle screws, two of which are pedicle screw combined with cement augmentation and expansive pedicle screw fixation. This biomechanical study was designed to compare the pullout strengths of two different revision techniques.
Methods: Fourteen lumbar vertebrae obtained from four calves (mean age 15 months) were divided into two groups equal in number. Monoaxial 6.0-mm pedicle screws were inserted into the right pedicles, and axial pullout testing was performed at a rate of 10 mm/min and failure strengths were recorded. Revision was performed with the same-sized pedicle screws reinforced with polymethylmethacrylate in group 1, and with 7.0-mm expansive pedicle screws in group 2, and pullout testing was repeated to record maximum revision pullout strengths.
Results: The mean pullout strengths recorded before and after revision were significantly different in both groups, being 2,162.9±718.5 N and 2,794.3±979.2 N in group 1 (p=0.041) and 2,605.0±487.6 N and 3,327.1±640.8 N in group 2 (p=0.012), respectively. However, the mean pullout strengths recorded before and after revision did not differ significantly between the two groups (p>0.05).
Conclusion: Our results showed that expansive pedicle screws 1 mm larger in diameter provide similar pullout strengths to those of same-sized, polymethylmethacrylatereinforced screws in revision of pedicle screw fixation, suggesting that they can be preferred with the additional advantages of ease of application and avoiding risks for pedicle fracture and cement leakage.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Bora Bostan Bu kişi benim

Irfan Esenkaya Bu kişi benim

Taner Gunes Bu kişi benim

Mehmet Erdem Bu kişi benim

Murat Asci Bu kişi benim

M. Halidun Kelestemur Bu kişi benim

Cengiz Sen Bu kişi benim

Yayımlanma Tarihi

10 Ağustos 2009

Gönderilme Tarihi

7 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2009 Cilt: 43 Sayı: 3

Kaynak Göster

APA
Bostan, B., Esenkaya, I., Gunes, T., Erdem, M., Asci, M., Kelestemur, M. H., & Sen, C. (2009). A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthopaedica et Traumatologica Turcica, 43(3), 272-276. https://izlik.org/JA96TP67KE
AMA
1.Bostan B, Esenkaya I, Gunes T, vd. A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthopaedica et Traumatologica Turcica. 2009;43(3):272-276. https://izlik.org/JA96TP67KE
Chicago
Bostan, Bora, Irfan Esenkaya, Taner Gunes, vd. 2009. “A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions”. Acta Orthopaedica et Traumatologica Turcica 43 (3): 272-76. https://izlik.org/JA96TP67KE.
EndNote
Bostan B, Esenkaya I, Gunes T, Erdem M, Asci M, Kelestemur MH, Sen C (01 Ağustos 2009) A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthopaedica et Traumatologica Turcica 43 3 272–276.
IEEE
[1]B. Bostan vd., “A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions”, Acta Orthopaedica et Traumatologica Turcica, c. 43, sy 3, ss. 272–276, Ağu. 2009, [çevrimiçi]. Erişim adresi: https://izlik.org/JA96TP67KE
ISNAD
Bostan, Bora - Esenkaya, Irfan - Gunes, Taner - Erdem, Mehmet - Asci, Murat - Kelestemur, M. Halidun - Sen, Cengiz. “A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions”. Acta Orthopaedica et Traumatologica Turcica 43/3 (01 Ağustos 2009): 272-276. https://izlik.org/JA96TP67KE.
JAMA
1.Bostan B, Esenkaya I, Gunes T, Erdem M, Asci M, Kelestemur MH, Sen C. A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthopaedica et Traumatologica Turcica. 2009;43:272–276.
MLA
Bostan, Bora, vd. “A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions”. Acta Orthopaedica et Traumatologica Turcica, c. 43, sy 3, Ağustos 2009, ss. 272-6, https://izlik.org/JA96TP67KE.
Vancouver
1.Bora Bostan, Irfan Esenkaya, Taner Gunes, Mehmet Erdem, Murat Asci, M. Halidun Kelestemur, Cengiz Sen. A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Ağustos 2009;43(3):272-6. Erişim adresi: https://izlik.org/JA96TP67KE