Accessory tendon slip arising from the extensor carpi ulnaris and its importance for wrist pain
Öz
Methods: The presence of an accessory tendinous slip from the ECU muscle was examined in terms of gross appearance, size, shape, thickness, location and distribution in 54 cadaveric forearms.
Results: The accessory slips arising from the ECU muscle were observed in three specimens (5.6%) (two left, one right). These slips ran to the ulnar side of the extensor digiti minimi tendon, originated from the head of the ECU, and ended on the extensor apparatus of the fifth finger. The mean width of the tendinous slips was 1.4±0.01 mm.
Conclusion: This anatomic variation of the ECU should be considered in diagnostic and surgical procedures involving the dorsum of the hand. Its clinical importance in the treatment of tenosynovitis and subluxation of joints is also stressed.