Araştırma Makalesi

The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures

Cilt: 46 Sayı: 3 1 Haziran 2012
  • Mehmet Aksekili
  • Ismail Celik
  • Arslan Arslan
  • Tughan Kalkan
  • Mahmut Ugurlu
PDF İndir
TR EN

The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures

Abstract

Objective: The aim of this study was to evaluate the time to union and complications in cases of tibial diaphysis and distal tibial fractures fixed with a minimally invasive percutaneous plate.
Methods: Thirty-five patients (23 males, 12 females) were operated on using minimally invasive percutaneous plate osteosynthesis (MIPPO) principles for tibial diaphysis and distal tibial fractures. Twenty-eight were closed and seven were open fractures. After direct or indirect fracture reduction, the plate was advanced through a submuscular extraperiosteal tunnel through the distal incision without opening the fracture line. The plate was fixed with screws through the proximal and distal incisions. Clinical and radiological evaluations were made at four to six week intervals after surgery. Full weight-bearing was allowed after an average of 14.43 (range: 12 to 20) weeks and 15.39 (range: 8 to 32) weeks in open and closed fractures, respectively. Duration of the union and complications were analyzed.
Results: The mean duration of the union was 20.7 (range: 16 to 28) weeks and 17.96 (range: 10 to 36) weeks in open and closed fractures, respectively. All cases showed union except one who had an implant failure. Necrosis at the wound developed in one case and infection in another.
Conclusion: MIPPO is an effective alternative treatment for tibial diaphysis and distal tibia fractures with low complication and high union rates.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Mehmet Aksekili Bu kişi benim

Ismail Celik Bu kişi benim

Arslan Arslan Bu kişi benim

Tughan Kalkan Bu kişi benim

Mahmut Ugurlu Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2012

Gönderilme Tarihi

7 Mart 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2012 Cilt: 46 Sayı: 3

Kaynak Göster

APA
Aksekili, M., Celik, I., Arslan, A., Kalkan, T., & Ugurlu, M. (2012). The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthopaedica et Traumatologica Turcica, 46(3), 161-167. https://izlik.org/JA34WX47RL
AMA
1.Aksekili M, Celik I, Arslan A, Kalkan T, Ugurlu M. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthopaedica et Traumatologica Turcica. 2012;46(3):161-167. https://izlik.org/JA34WX47RL
Chicago
Aksekili, Mehmet, Ismail Celik, Arslan Arslan, Tughan Kalkan, ve Mahmut Ugurlu. 2012. “The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures”. Acta Orthopaedica et Traumatologica Turcica 46 (3): 161-67. https://izlik.org/JA34WX47RL.
EndNote
Aksekili M, Celik I, Arslan A, Kalkan T, Ugurlu M (01 Haziran 2012) The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthopaedica et Traumatologica Turcica 46 3 161–167.
IEEE
[1]M. Aksekili, I. Celik, A. Arslan, T. Kalkan, ve M. Ugurlu, “The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 46, sy 3, ss. 161–167, Haz. 2012, [çevrimiçi]. Erişim adresi: https://izlik.org/JA34WX47RL
ISNAD
Aksekili, Mehmet - Celik, Ismail - Arslan, Arslan - Kalkan, Tughan - Ugurlu, Mahmut. “The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures”. Acta Orthopaedica et Traumatologica Turcica 46/3 (01 Haziran 2012): 161-167. https://izlik.org/JA34WX47RL.
JAMA
1.Aksekili M, Celik I, Arslan A, Kalkan T, Ugurlu M. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthopaedica et Traumatologica Turcica. 2012;46:161–167.
MLA
Aksekili, Mehmet, vd. “The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 46, sy 3, Haziran 2012, ss. 161-7, https://izlik.org/JA34WX47RL.
Vancouver
1.Mehmet Aksekili, Ismail Celik, Arslan Arslan, Tughan Kalkan, Mahmut Ugurlu. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Haziran 2012;46(3):161-7. Erişim adresi: https://izlik.org/JA34WX47RL