TR
EN
Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment
Abstract
Objective: The aim of this study was to compare the biomechanical strength of three fixation methods in humerus shaft fractures with medial butterfly fragment.
Methods: An AO 12B2 fracture with butterfly fragment was created in 21 synthetic cortical shell humeri. Humeri were divided into 3 groups which underwent bridge plating, antegrade intramedullary nailing or retrograde intramedullary nailing. Rotational and four-point bending test displacement curves were obtained.
Results: Mean displacement values in the torsion tests were 37.38 (range: 25.75 to 55.69) mm in the bridge plating group, 26.55 (range: 21.25 to 41.81) mm in the antegrade nailing group, and 33.23
(range: 27.50 to 46.45) mm in the retrograde nailing group. Mean displacement values in the fourpoint bending test were 3.27 (range: 2.54 to 3.73) mm in the bridge plating group, 3.17 (range: 2.69
to 3.55) mm in the antegrade nailing group, and 3.15 (range: 2.10 to 4.03) mm in the retrograde nailing group. No significant difference was found among the groups (p>0.05).
Conclusion: The biomechanical stability of bridge plating, antegrade intramedullary nailing and retrograde intramedullary nailing appears to be similar in the fixation of humerus shaft fractures with medial butterfly fragment.
Methods: An AO 12B2 fracture with butterfly fragment was created in 21 synthetic cortical shell humeri. Humeri were divided into 3 groups which underwent bridge plating, antegrade intramedullary nailing or retrograde intramedullary nailing. Rotational and four-point bending test displacement curves were obtained.
Results: Mean displacement values in the torsion tests were 37.38 (range: 25.75 to 55.69) mm in the bridge plating group, 26.55 (range: 21.25 to 41.81) mm in the antegrade nailing group, and 33.23
(range: 27.50 to 46.45) mm in the retrograde nailing group. Mean displacement values in the fourpoint bending test were 3.27 (range: 2.54 to 3.73) mm in the bridge plating group, 3.17 (range: 2.69
to 3.55) mm in the antegrade nailing group, and 3.15 (range: 2.10 to 4.03) mm in the retrograde nailing group. No significant difference was found among the groups (p>0.05).
Conclusion: The biomechanical stability of bridge plating, antegrade intramedullary nailing and retrograde intramedullary nailing appears to be similar in the fixation of humerus shaft fractures with medial butterfly fragment.
Keywords
Kaynakça
- Ekholm R, Adami J, Tidermark J, Hansson K, Törnkvist H, Ponzer S. Fractures of the shaft of the humerus. An epidemi- ological study of 401 fractures. J Bone Joint Surg Br 2006;88: 1469-73.
- Tytherleigh-Strong G, Walls N, McQueen MM. The epi- demiology of humeral shaft fractures. J Bone Joint Surg Br 1998;80:249-53.
- Castellá FB, Garcia FB, Berry EM, Perelló EB, Sánchez- Alepuz E, Gabarda R. Nonunion of the humeral shaft: long lateral butterfly fracture – a nonunion predictive pattern? Clin Orthop Relat Res 2004;(424):227-30.
- Jupiter JB, von Deck M. Ununited humeral diaphyses. J Shoulder Elbow Surg 1998;7:644-53.
- Klenerman L. Fractures of the shaft of the humerus. J Bone Joint Surg Br 1966;48:105-11.
- Modabber MR, Jupiter JB. Operative management of diaphy- seal fractures of the humerus. Plate versus nail. Clin Orthop Relat Res 1998;(347):93-104.
- Zagorski JB, Latta LL, Zych GA, Finnieston AR. Diaphyseal fractures of the humerus. Treatment with prefabricated braces. J Bone Joint Surg Am 1988;70:607-10.
- Blum J, Karagül G, Sternstein W, Rommens PM. Bending and torsional stiffness in cadaver humeri fixed with a self-lock- ing expandable or interlocking nail system: a mechanical study. J Orthop Trauma 2005;19:535-42.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Sağlık Kurumları Yönetimi
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
11 Haziran 2013
Gönderilme Tarihi
7 Mart 2014
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2013 Cilt: 47 Sayı: 3
APA
Turken, M., Akdemir, M., Uzun, B., & Ozkan, M. (2013). Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment. Acta Orthopaedica et Traumatologica Turcica, 47(3), 173-178. https://izlik.org/JA78ER47HU
AMA
1.Turken M, Akdemir M, Uzun B, Ozkan M. Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment. Acta Orthopaedica et Traumatologica Turcica. 2013;47(3):173-178. https://izlik.org/JA78ER47HU
Chicago
Turken, Mehmet, Mehmet Akdemir, Bora Uzun, ve Mustafa Ozkan. 2013. “Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment”. Acta Orthopaedica et Traumatologica Turcica 47 (3): 173-78. https://izlik.org/JA78ER47HU.
EndNote
Turken M, Akdemir M, Uzun B, Ozkan M (01 Haziran 2013) Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment. Acta Orthopaedica et Traumatologica Turcica 47 3 173–178.
IEEE
[1]M. Turken, M. Akdemir, B. Uzun, ve M. Ozkan, “Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment”, Acta Orthopaedica et Traumatologica Turcica, c. 47, sy 3, ss. 173–178, Haz. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA78ER47HU
ISNAD
Turken, Mehmet - Akdemir, Mehmet - Uzun, Bora - Ozkan, Mustafa. “Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment”. Acta Orthopaedica et Traumatologica Turcica 47/3 (01 Haziran 2013): 173-178. https://izlik.org/JA78ER47HU.
JAMA
1.Turken M, Akdemir M, Uzun B, Ozkan M. Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment. Acta Orthopaedica et Traumatologica Turcica. 2013;47:173–178.
MLA
Turken, Mehmet, vd. “Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment”. Acta Orthopaedica et Traumatologica Turcica, c. 47, sy 3, Haziran 2013, ss. 173-8, https://izlik.org/JA78ER47HU.
Vancouver
1.Mehmet Turken, Mehmet Akdemir, Bora Uzun, Mustafa Ozkan. Biomechanical evaluation of different internal fixation methods for humerus shaft fractures with medial butterfly fragment. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Haziran 2013;47(3):173-8. Erişim adresi: https://izlik.org/JA78ER47HU