Araştırma Makalesi
BibTex RIS Kaynak Göster

Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures

Yıl 2010, Cilt: 44 Sayı: 6, 443 - 451, 07.02.2011
https://izlik.org/JA34SD78FH

Öz

Objectives: The aim of this study was to compare the long-term results of two groups of patients with trochanteric fractures of the femur treated with either dynamic hip screw (DHS) or AO angled blade plate (AP) insertions.
Methods: A total of 157 patients with trochanteric fractures were included in the study, and 82 patients underwent dynamic hip screw insertion, and 75 underwent AO angled blade plate insertion. The mean follow-up period was 8 years (range 2.3-11.7 years) in the DHS group, and 8.5 years (2.4-12.5 years) in the AP group.
Results: According to the Boyd and Griffin classification, there were 37 stable fractures (45%) and 45 unstable fractures (55%) in the DHS group, whereas there were 42 stable fractures (56%) and 33 unstable fractures (44%) in the AP group. According to Clawson’s functional classification, 64% of patients in the AP group and 81% in the DHS group had good or excellent function (p<0.05). Similarly, according to Foster's classification, 68% of patients in the AP group, and 85% in the DHS group had good to excellent results (p<0.05).
Conclusion: DHS yields better long-term results in trochanteric fractures than do AO angled blade plates by providing earlier mobilization of the patient, better stability, and earlier union. 

Yıl 2010, Cilt: 44 Sayı: 6, 443 - 451, 07.02.2011
https://izlik.org/JA34SD78FH

Öz

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Sağlık Kurumları Yönetimi
Bölüm Araştırma Makalesi
Yazarlar

Orhan Akinci Bu kişi benim

Yavuz Akalin Bu kişi benim

Ali Reisoglu Bu kişi benim

Cemil Kayali Bu kişi benim

Yayımlanma Tarihi 7 Şubat 2011
IZ https://izlik.org/JA34SD78FH
Yayımlandığı Sayı Yıl 2010 Cilt: 44 Sayı: 6

Kaynak Göster

APA Akinci, O., Akalin, Y., Reisoglu, A., & Kayali, C. (2011). Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures. Acta Orthopaedica et Traumatologica Turcica, 44(6), 443-451. https://izlik.org/JA34SD78FH
AMA 1.Akinci O, Akalin Y, Reisoglu A, Kayali C. Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;44(6):443-451. https://izlik.org/JA34SD78FH
Chicago Akinci, Orhan, Yavuz Akalin, Ali Reisoglu, ve Cemil Kayali. 2011. “Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures”. Acta Orthopaedica et Traumatologica Turcica 44 (6): 443-51. https://izlik.org/JA34SD78FH.
EndNote Akinci O, Akalin Y, Reisoglu A, Kayali C (01 Şubat 2011) Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures. Acta Orthopaedica et Traumatologica Turcica 44 6 443–451.
IEEE [1]O. Akinci, Y. Akalin, A. Reisoglu, ve C. Kayali, “Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 44, sy 6, ss. 443–451, Şub. 2011, [çevrimiçi]. Erişim adresi: https://izlik.org/JA34SD78FH
ISNAD Akinci, Orhan - Akalin, Yavuz - Reisoglu, Ali - Kayali, Cemil. “Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures”. Acta Orthopaedica et Traumatologica Turcica 44/6 (01 Şubat 2011): 443-451. https://izlik.org/JA34SD78FH.
JAMA 1.Akinci O, Akalin Y, Reisoglu A, Kayali C. Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures. Acta Orthopaedica et Traumatologica Turcica. 2011;44:443–451.
MLA Akinci, Orhan, vd. “Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 44, sy 6, Şubat 2011, ss. 443-51, https://izlik.org/JA34SD78FH.
Vancouver 1.Akinci O, Akalin Y, Reisoglu A, Kayali C. Comparison of long-term results of dynamic hip screw and AO 130 degrees blade plate in adult trochanteric region fractures. Acta Orthopaedica et Traumatologica Turcica [Internet]. 01 Şubat 2011;44(6):443-51. Erişim adresi: https://izlik.org/JA34SD78FH