Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures

Cilt: 42 Sayı: 5 19 Ocak 2009
  • Ufuk Nalbantoglu
  • Arel Gereli
  • Yavuz Ucar
  • Metin Turkmen
PDF İndir
EN TR

Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures

Abstract

Objectives: We compared the results of fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Methods: Sixty-three patients (64 radii) with distal radius fractures were treated with dorsal T plate (n=41) or palmar locking plate (n=23). The mean age was 46±14 years (range 21 to 82 years) in the dorsal and 47±14 years (range 18 to 69 years) in the palmar plate groups. The fractures were classified according to the AO/ASIF system. Objective and subjective functional assessments were made using the Gartland-Werley and Quick-DASH scales, respectively. The mean follow-up was 78±19 months (range 12 to 101 months) and 18±5 months (range 12 to 28 months) with dorsal and palmar plating, respectively. Results: The mean Gartland-Werley and Quick-DASH scores were 2.3±2.1 (range 0 to 9) and 2.0±2.2 (range 0 to 9) with dorsal plating, and 2.0±2.1 (range 0 to 6) and 1.9±2.7 (range 0 to 9) with palmar plating, respectively. The two groups did not differ with respect to Gartland-Werley and Quick-DASH scores (p>0.05). Time to return work or daily activities was also similar (1.9±0.3 months vs 1.8±0.4 months). However, patients treated with dorsal plating exhibited significantly greater values in the following parameters measured on early and late postoperative radiograms: loss of palmar tilt (p=0.001), radial height (p=0.001), radial inclination (p=0.049), and change in ulnar variance (p=0.049). Moreover, complications were seen in eight patients (19.5%) with dorsal plating, whereas no complications occurred with palmar locking plate (p=0.024). Conclusion: Although the two fixation methods do not differ with respect to functional results, palmar locking plating seems to provide a more rigid fixation resulting in significantly reduced collapse and a very low complication rate.

Keywords

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Ufuk Nalbantoglu Bu kişi benim

Arel Gereli Bu kişi benim

Yavuz Ucar Bu kişi benim

Metin Turkmen Bu kişi benim

Yayımlanma Tarihi

19 Ocak 2009

Gönderilme Tarihi

10 Mayıs 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2008 Cilt: 42 Sayı: 5

Kaynak Göster

APA
Nalbantoglu, U., Gereli, A., Ucar, Y., & Turkmen, M. (2009). Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthopaedica et Traumatologica Turcica, 42(5), 365-372. https://doi.org/10.3944/aott.v42i5.3519
AMA
1.Nalbantoglu U, Gereli A, Ucar Y, Turkmen M. Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthopaedica et Traumatologica Turcica. 2009;42(5):365-372. doi:10.3944/aott.v42i5.3519
Chicago
Nalbantoglu, Ufuk, Arel Gereli, Yavuz Ucar, ve Metin Turkmen. 2009. “Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures”. Acta Orthopaedica et Traumatologica Turcica 42 (5): 365-72. https://doi.org/10.3944/aott.v42i5.3519.
EndNote
Nalbantoglu U, Gereli A, Ucar Y, Turkmen M (01 Ocak 2009) Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthopaedica et Traumatologica Turcica 42 5 365–372.
IEEE
[1]U. Nalbantoglu, A. Gereli, Y. Ucar, ve M. Turkmen, “Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures”, Acta Orthopaedica et Traumatologica Turcica, c. 42, sy 5, ss. 365–372, Oca. 2009, doi: 10.3944/aott.v42i5.3519.
ISNAD
Nalbantoglu, Ufuk - Gereli, Arel - Ucar, Yavuz - Turkmen, Metin. “Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures”. Acta Orthopaedica et Traumatologica Turcica 42/5 (01 Ocak 2009): 365-372. https://doi.org/10.3944/aott.v42i5.3519.
JAMA
1.Nalbantoglu U, Gereli A, Ucar Y, Turkmen M. Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthopaedica et Traumatologica Turcica. 2009;42:365–372.
MLA
Nalbantoglu, Ufuk, vd. “Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures”. Acta Orthopaedica et Traumatologica Turcica, c. 42, sy 5, Ocak 2009, ss. 365-72, doi:10.3944/aott.v42i5.3519.
Vancouver
1.Ufuk Nalbantoglu, Arel Gereli, Yavuz Ucar, Metin Turkmen. Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures. Acta Orthopaedica et Traumatologica Turcica. 01 Ocak 2009;42(5):365-72. doi:10.3944/aott.v42i5.3519