Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?

Cilt: 49 Sayı: 4 19 Ağustos 2015
  • Oluwasegun Akilapa
  • Andy Gaffey
PDF İndir
EN

Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?

Öz

Objective: Several clinical studies have reported that the use of hydroxyapatite- (HA) coated pins enhance external fixation. Although these studies have demonstrated higher extraction torques and lower rates of pin loosening with HA coating, there is little evidence to suggest that these biomechanical advantages translate to a lower rate of pin replacement prior to healing. The research question posed was “Is there sufficient evidence to prove that hydroxyapatite coating lowers the rate of pin replacement for external fixation?”
Methods: An electronic search of Medline (Ovid, 1946 - December Week 4 2011), Embase (Ovid, 1980—2011 Week 52), and the Cochrane Central Register of Controlled Trials (Issue 4 of 4, October 2011) was conducted to identify all randomized and quasi-randomized controlled trials which compared HA-coated pins with non-coated pins for external fixation, with particular emphasis on the premature replacement of pins as a consequence of loosening.
Results: The combined search strategies retrieved 72 citations. Four randomized controlled trials (101 patients, 327 HA-coated vs. 354 uncoated pins) were included in this review. None of the studies demonstrated a clear benefit between pin types with respect to premature replacement of pins prior to healing.
Conclusion: This review did not find sufficient evidence to validate the preferential use of HA-coated pins over standard pins as a means of avoiding premature replacement of pins used for external fixation. The use of uncoated pins is justifiable, especially within the context of limited financial resources.

 

DOI: 10.3944/AOTT.2015.14.0206


Anahtar Kelimeler

Kaynakça

  1. http://www.ncbi.nlm.nih.gov/mesh (accessed 20th of April/2012).
  2. Moroni A, Vannini F, Mosca M, Giannini S. State of the art review: techniques to avoid pin loosening and infection in external fixation. J Orthop Trauma 2002;16:189–95.
  3. Carlos JL, Carneiro J. Inorganic matter represents about 50% of the dry weight of bone. In: Boyle P, editor. Basic Histology, Text & Atlas. 10th ed. McGraw-Hill Compa- nies; 2003. 4 Moroni A, Heikkila J, Magyar G, Toksvig-Larsen S, Gi- annini S. Fixation strength and pin tract infection of hy- droxyapatite-coated tapered pins. Clin Orthop Relat Res 2001;388:209–17.
  4. Higgins JP, Altman DG, Gİtzsche PC, Jüni P, Moher D, et al. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 2011;343:d5928.
  5. Caja VL, Piză G, Navarro A. Hydroxyapatite coating of external fixation pins to decrease axial deformity during tibial lengthening for short stature. J Bone Joint Surg Am 2003;85-A:1527–31.
  6. Pizà G, Caja VL, González-Viejo MA, Navarro A. Hy- droxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg Br 2004;86:892–7.
  7. Pieske O, Kaltenhauser F, Pichlmaier L, Schramm N, Trentzsch H, Löffler T, et al. Clinical benefit of hydroxy- apatite-coated pins compared with stainless steel pins in external fixation at the wrist: a randomised prospective study. Injury 2010;41:1031–6.
  8. Pieske O, Pichlmaier L, Kaltenhauser F, Schramm N, Ru- benbauer B, Greiner A, et al. Hydroxyapatite-coated pins versus titanium alloy pins in external fixation at the wrist: a controlled cohort study. J Trauma 2011;70:845–51.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Oluwasegun Akilapa Bu kişi benim

Andy Gaffey Bu kişi benim

Yayımlanma Tarihi

19 Ağustos 2015

Gönderilme Tarihi

5 Ağustos 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2015 Cilt: 49 Sayı: 4

Kaynak Göster

APA
Akilapa, O., & Gaffey, A. (2015). Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely? Acta Orthopaedica et Traumatologica Turcica, 49(4), 410-415. https://doi.org/10.3944/AOTT.2015.14.0206
AMA
1.Akilapa O, Gaffey A. Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely? Acta Orthopaedica et Traumatologica Turcica. 2015;49(4):410-415. doi:10.3944/AOTT.2015.14.0206
Chicago
Akilapa, Oluwasegun, ve Andy Gaffey. 2015. “Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?”. Acta Orthopaedica et Traumatologica Turcica 49 (4): 410-15. https://doi.org/10.3944/AOTT.2015.14.0206.
EndNote
Akilapa O, Gaffey A (01 Ağustos 2015) Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely? Acta Orthopaedica et Traumatologica Turcica 49 4 410–415.
IEEE
[1]O. Akilapa ve A. Gaffey, “Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?”, Acta Orthopaedica et Traumatologica Turcica, c. 49, sy 4, ss. 410–415, Ağu. 2015, doi: 10.3944/AOTT.2015.14.0206.
ISNAD
Akilapa, Oluwasegun - Gaffey, Andy. “Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?”. Acta Orthopaedica et Traumatologica Turcica 49/4 (01 Ağustos 2015): 410-415. https://doi.org/10.3944/AOTT.2015.14.0206.
JAMA
1.Akilapa O, Gaffey A. Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely? Acta Orthopaedica et Traumatologica Turcica. 2015;49:410–415.
MLA
Akilapa, Oluwasegun, ve Andy Gaffey. “Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely?”. Acta Orthopaedica et Traumatologica Turcica, c. 49, sy 4, Ağustos 2015, ss. 410-5, doi:10.3944/AOTT.2015.14.0206.
Vancouver
1.Oluwasegun Akilapa, Andy Gaffey. Hydroxyapatite pins for external fixation: is there sufficient evidence to prove that coated pins are less likely to be replaced prematurely? Acta Orthopaedica et Traumatologica Turcica. 01 Ağustos 2015;49(4):410-5. doi:10.3944/AOTT.2015.14.0206