BibTex RIS Kaynak Göster

Application of Chevron operation for patients with hallux valgus deformities and their results

Yıl 1991, Cilt: 25 Sayı: 3, 135 - 137, 11.09.2006

Öz

The Chevron osteotomy realignment of the first metatarsal head in hallux valgus deformity has been utilized at our clinics For the last six years on 52 feet (35 patientst Follow up evaluation disclosed excellent relief of pain, good cosmetic correction and overall patient satisfaction Radiographic evaluation demostrated reduction in the angle between the phalanx and the metatarsal bone of the great toe as well as narrowing of the forefoot with a decreased angle between the first and the second melatarsal bones. The stability of the osteotomy, the technical ease and the absence of secondary difficulties such as transfer metatarsalgia make this procedure preferable when osteotomy of the distal portion of the first metatarsal bone is used for correction of moderate deformity.

Halluks valgus deformiteli olgulara Chevron operasyonu uygulaması ve sonuçları

Yıl 1991, Cilt: 25 Sayı: 3, 135 - 137, 11.09.2006

Öz

Halluks valgus deformitelerinde birinci metatarsın yeniden doğrultulabilmesi için son 6 yıldır kliniklerimizde 52 ayağa Chevron osteotomisi uyguladık. İzleme süresince olgularımızın çoğunluğunda ağrının ortadan kalkması ve kozmetik görünümün düzelmesini memnuniyet verici düzeyde saptadık. Radyolojik değerlendirmelerde falanks ile birinci metatars arasındaki açıda ve birinci ile ikinci metatars arasındaki açıda azalma saptadık Orta derecedeki deformitelerin düzeltilmesi için birinci metatars kemiğinin distalinden osteotomi yapılacaksa, osteotominin stabil olması teknik kolaylık ve metataraljinin oluşmaması nedeniyle bu işlem tercih edilmelidir.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Orijinal Makale
Yazarlar

Ugur Gunel Bu kişi benim

Ali Bicimoglu Bu kişi benim

Savas Agaoglu Bu kişi benim

Rasit Cesur Bu kişi benim

Yalcin Tabak Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1991 Cilt: 25 Sayı: 3

Kaynak Göster

APA Gunel, U., Bicimoglu, A., Agaoglu, S., Cesur, R., vd. (2006). Application of Chevron operation for patients with hallux valgus deformities and their results. Acta Orthopaedica Et Traumatologica Turcica, 25(3), 135-137. https://doi.org/10.3944/aott.v25i3.1209
AMA Gunel U, Bicimoglu A, Agaoglu S, Cesur R, Tabak Y. Application of Chevron operation for patients with hallux valgus deformities and their results. Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;25(3):135-137. doi:10.3944/aott.v25i3.1209
Chicago Gunel, Ugur, Ali Bicimoglu, Savas Agaoglu, Rasit Cesur, ve Yalcin Tabak. “Application of Chevron Operation for Patients With Hallux Valgus Deformities and Their Results”. Acta Orthopaedica Et Traumatologica Turcica 25, sy. 3 (Eylül 2006): 135-37. https://doi.org/10.3944/aott.v25i3.1209.
EndNote Gunel U, Bicimoglu A, Agaoglu S, Cesur R, Tabak Y (01 Eylül 2006) Application of Chevron operation for patients with hallux valgus deformities and their results. Acta Orthopaedica et Traumatologica Turcica 25 3 135–137.
IEEE U. Gunel, A. Bicimoglu, S. Agaoglu, R. Cesur, ve Y. Tabak, “Application of Chevron operation for patients with hallux valgus deformities and their results”, Acta Orthopaedica et Traumatologica Turcica, c. 25, sy. 3, ss. 135–137, 2006, doi: 10.3944/aott.v25i3.1209.
ISNAD Gunel, Ugur vd. “Application of Chevron Operation for Patients With Hallux Valgus Deformities and Their Results”. Acta Orthopaedica et Traumatologica Turcica 25/3 (Eylül 2006), 135-137. https://doi.org/10.3944/aott.v25i3.1209.
JAMA Gunel U, Bicimoglu A, Agaoglu S, Cesur R, Tabak Y. Application of Chevron operation for patients with hallux valgus deformities and their results. Acta Orthopaedica et Traumatologica Turcica. 2006;25:135–137.
MLA Gunel, Ugur vd. “Application of Chevron Operation for Patients With Hallux Valgus Deformities and Their Results”. Acta Orthopaedica Et Traumatologica Turcica, c. 25, sy. 3, 2006, ss. 135-7, doi:10.3944/aott.v25i3.1209.
Vancouver Gunel U, Bicimoglu A, Agaoglu S, Cesur R, Tabak Y. Application of Chevron operation for patients with hallux valgus deformities and their results. Acta Orthopaedica et Traumatologica Turcica. 2006;25(3):135-7.