Artificialligaments seemed to be the solution for ACL reconstruction and Goretex and Dacron were the most popular materials used for this purpose. In this paper we report the long-term results of the Dacron ProfIex prosthetic replacement of the ACL. These results were compared with those achieved in another group of patients in whom the patellar-bone-tendon-bone autogratt technique has been performed. A hig'' rate of ACL insufficiency was observed in the Dacron prosthesis group. Considering the risk of rupture and the chronic synovitis related to the reaction to the synthetic material, we think that the Dacron prothesis could be indicated in patients over 40, with limited functional demands or in case of failure of previous biological reconstructions
Ön çapraz bağ rekonstrüksiyonunda yapay ligamanlar iyi bir çözüm olarak görülmekteydi ve Goretex ve Dacron bu amaçla kullamlan en popüler materyallerdir. Bu çalışmada OÇB için prostetik replasmanda kullanıIan Dacron Proflexin sonuçları sunulmuştur. Bu sonuçlar otogreft olarak, patellar tendon kullanımıyla rekonstrüksiyon yapıldığı diğer vakaların sonuçlarıyla karşılaştırılmıştır. Dacron protez grubunda yüksek oranda OÇB yetmezliği saptanmıştır. Yırtılma ve sentetik materyal reaksiyonu olarak kronik sinovit düşünüldüğünde, bizce Dacron protezi 40 yaşın üstünde, sınırlı aktivite düzeyi ve ihtiyaçları olan hastalar veya daha önce yapılan biyolojik rekonstrüksiyonun başarısız kaldığı vakalar için saklanmalıdır.
Birincil Dil | İngilizce |
---|---|
Bölüm | Orijinal Makale |
Yazarlar | |
Yayımlanma Tarihi | 11 Eylül 2006 |
Yayımlandığı Sayı | Yıl 1994 Cilt: 28 Sayı: 5 |