BibTex RIS Kaynak Göster

The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls

Yıl 1994, Cilt: 28 Sayı: 5, 332 - 337, 11.09.2006

Öz

In this study, we evaluated the results of sliding type unicompartmental knee prosthesis whichwas performedat Holzminden Protestan Hospitalbetween April1,1987 and May 31,1993. We have performed 95 knee prostheses in 83 patients. 80 female, 3 male patients with the mean age of 71 constitute our material. Mean fo1low up period was 41 months (Ranged 4 months to 120 months). On conclusion sliding type unicompartmental knee prosthesis is a safe method in the treatment of gonarthrosis. Implantation errors compromise long term results. A tibial component placed in properly increase the load on cruciate ligaments.

Kızak protezlerinde implantasyon hatasına bağlı olarak ortaya çıkan kaydırma momentinin önemi

Yıl 1994, Cilt: 28 Sayı: 5, 332 - 337, 11.09.2006

Öz

Bu çalışmada 1 Nisan 1987- 31 Mayıs 1993 tarihleri arasında Holzminden Protestan Hastanesinde gonartroz nedeniyle yapılan kızak protezi ameliyatların sonuçları değerlendirilmiştir. 83 hastanın 95 dizine kızak protezi uygulanmıştır. Vaka serimizi 80 kadın, 3 erkek hasta oluşturmuş olup, ortalama yaş 71 , ortalama takip süresi 41 ay (en az 4 ay, en fazla 120 ay) olarak gerçek!eşmiştir. %89 subjektif çok iyi ve iyi sonuç elde edilmiştir. Biz diz eklemi artrozunda kızak protezinin emin bir'yer edindiği kanısındayız. Teknik implantasyon hataları ameliyat sonucunu tehlikeye atan en büyük sebeptir

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Orijinal Makale
Yazarlar

Mustafa Yucel Bu kişi benim

J. Paulun Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1994 Cilt: 28 Sayı: 5

Kaynak Göster

APA Yucel, M., & Paulun, J. (2006). The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls. Acta Orthopaedica Et Traumatologica Turcica, 28(5), 332-337. https://doi.org/10.3944/aott.v28i5.1521
AMA Yucel M, Paulun J. The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls. Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;28(5):332-337. doi:10.3944/aott.v28i5.1521
Chicago Yucel, Mustafa, ve J. Paulun. “The Importance of Sliding Moment Which Is Caused by Implantatlon Errors in Unicompartmontal Knee Prosthesls”. Acta Orthopaedica Et Traumatologica Turcica 28, sy. 5 (Eylül 2006): 332-37. https://doi.org/10.3944/aott.v28i5.1521.
EndNote Yucel M, Paulun J (01 Eylül 2006) The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls. Acta Orthopaedica et Traumatologica Turcica 28 5 332–337.
IEEE M. Yucel ve J. Paulun, “The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls”, Acta Orthopaedica et Traumatologica Turcica, c. 28, sy. 5, ss. 332–337, 2006, doi: 10.3944/aott.v28i5.1521.
ISNAD Yucel, Mustafa - Paulun, J. “The Importance of Sliding Moment Which Is Caused by Implantatlon Errors in Unicompartmontal Knee Prosthesls”. Acta Orthopaedica et Traumatologica Turcica 28/5 (Eylül 2006), 332-337. https://doi.org/10.3944/aott.v28i5.1521.
JAMA Yucel M, Paulun J. The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls. Acta Orthopaedica et Traumatologica Turcica. 2006;28:332–337.
MLA Yucel, Mustafa ve J. Paulun. “The Importance of Sliding Moment Which Is Caused by Implantatlon Errors in Unicompartmontal Knee Prosthesls”. Acta Orthopaedica Et Traumatologica Turcica, c. 28, sy. 5, 2006, ss. 332-7, doi:10.3944/aott.v28i5.1521.
Vancouver Yucel M, Paulun J. The importance of sliding moment which is caused by implantatlon errors in unicompartmontal knee prosthesls. Acta Orthopaedica et Traumatologica Turcica. 2006;28(5):332-7.