BibTex RIS Kaynak Göster

Measuring spine pedicle diameters in Turkish people using computed tomography

Yıl 1995, Cilt: 29 Sayı: 3, 227 - 228, 11.09.2006

Öz

In this study, using computed tomography, in 111 adult pearsons (60 men, 51 women), the pedicle diameters of L1, L2, L3, L4, L5 and S1 were measured and these measurements were compared with pedicle screw diameters commonly used spine surgery. The pedicle diameter at each level was measured and averaged for all patients and for men and women separately. The average pedicle diameters of women were 4.78 for L1 (%62.7 were less than 5mm), 5.44 mm for L2 (%96 were less than 7 mm), 6.96 mm for L3 (%52.9 were less than 7 mm), 9.24 mm for L4, 12.28 mm for L5, 17.24 mm for S1, and men were 5.76 mm for L1 (%20 were less than 5 mm), 6.3 mm for L2 (%71.6 were less than 7 mm), 7.98 mm for L3 (%16.2 were less than 7mm), 9.9 mm for L4, 13.7 mm for L5, 18.5 mm for S1. According to these results, at each sexuality, pedicle screws with 7 mm outer diameter can be used safely for L4, L5 and S1 pedicle. For L1, L2 and L3 pedicle should be obtained preoperative computed tomography pedicle measurements to prevent complications.

Türk toplumunda vertebra pediküler çaplarının bilgisayarlı tomografi ile ölçülmesi

Yıl 1995, Cilt: 29 Sayı: 3, 227 - 228, 11.09.2006

Öz

Bu çalışmada, Bilgisayarlı Tomografi (BT) kullanılarak, 60'ı erkek, 51'i kadın, toplam 111 erişkin şahısta, L1, L2, L3, L4,L5 ve S1 pedikül çapları ölçüldü ve bu ölçümler vertebra cerrahisinde sıklıkla kullanılan pedikül vida çaplarıyla karşılaştırıldı. Tüm seviyedeki ölçümler cinslere göre ayrı ayrı değerlendirildi. Kadınlar için ortalama pedikül çapları L1'de 4.78 mm (% 62.7'si 5mm'den küçük), L2'de 5.44 mm (%96'sı 7 mm'den küçük), L3'de 6.99 mm (%52.9'u 7mm'den küçük), L4'de 9.24 mm, L5'te 12.28 mm, S1'de 17.24 mm (L4, L5 ve S1'de tüm değerler 7 mm'den büyük) olarak bulundu. Erkekler için ortalama pedüküler çapları L1'de 5.76 mm (%20'si 5 mm'den küçük), L2'de 6.3 mm (%71.6'sı 7 mm'den küçük), L3'de 7.98 mm (%16.2'si 7 mm'den küçük), L4'de 9.9 mm, L5'de 13.7 mm, S1'de 18.5 mm (L4, L5 ve S1'de tüm değerler 7 mm'den büyük) olarak bulundu. Sonuçlara göre; her iki cinste L4, L5 ve S1'de 7 mm çapında pedikül vidaları güvenli olarak kullanılabilir. L1, L2 ve L3'de ise komplikasyonları önlemek için BT ile preoperatif pedikül ölçümü yapılması gereklidir.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Deneysel Çalışma
Yazarlar

M.akif Kaygusuz Bu kişi benim

Kaya Sarac Bu kişi benim

Nurzat Elmali Bu kişi benim

Tamer Baysal Bu kişi benim

Ayhan Boluk Bu kişi benim

Azmi Hamzaoglu Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1995 Cilt: 29 Sayı: 3

Kaynak Göster

APA Kaygusuz, M., Sarac, K., Elmali, N., Baysal, T., vd. (2006). Measuring spine pedicle diameters in Turkish people using computed tomography. Acta Orthopaedica Et Traumatologica Turcica, 29(3), 227-228. https://doi.org/10.3944/aott.v29i3.1594
AMA Kaygusuz M, Sarac K, Elmali N, Baysal T, Boluk A, Hamzaoglu A. Measuring spine pedicle diameters in Turkish people using computed tomography. Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;29(3):227-228. doi:10.3944/aott.v29i3.1594
Chicago Kaygusuz, M.akif, Kaya Sarac, Nurzat Elmali, Tamer Baysal, Ayhan Boluk, ve Azmi Hamzaoglu. “Measuring Spine Pedicle Diameters in Turkish People Using Computed Tomography”. Acta Orthopaedica Et Traumatologica Turcica 29, sy. 3 (Eylül 2006): 227-28. https://doi.org/10.3944/aott.v29i3.1594.
EndNote Kaygusuz M, Sarac K, Elmali N, Baysal T, Boluk A, Hamzaoglu A (01 Eylül 2006) Measuring spine pedicle diameters in Turkish people using computed tomography. Acta Orthopaedica et Traumatologica Turcica 29 3 227–228.
IEEE M. Kaygusuz, K. Sarac, N. Elmali, T. Baysal, A. Boluk, ve A. Hamzaoglu, “Measuring spine pedicle diameters in Turkish people using computed tomography”, Acta Orthopaedica et Traumatologica Turcica, c. 29, sy. 3, ss. 227–228, 2006, doi: 10.3944/aott.v29i3.1594.
ISNAD Kaygusuz, M.akif vd. “Measuring Spine Pedicle Diameters in Turkish People Using Computed Tomography”. Acta Orthopaedica et Traumatologica Turcica 29/3 (Eylül 2006), 227-228. https://doi.org/10.3944/aott.v29i3.1594.
JAMA Kaygusuz M, Sarac K, Elmali N, Baysal T, Boluk A, Hamzaoglu A. Measuring spine pedicle diameters in Turkish people using computed tomography. Acta Orthopaedica et Traumatologica Turcica. 2006;29:227–228.
MLA Kaygusuz, M.akif vd. “Measuring Spine Pedicle Diameters in Turkish People Using Computed Tomography”. Acta Orthopaedica Et Traumatologica Turcica, c. 29, sy. 3, 2006, ss. 227-8, doi:10.3944/aott.v29i3.1594.
Vancouver Kaygusuz M, Sarac K, Elmali N, Baysal T, Boluk A, Hamzaoglu A. Measuring spine pedicle diameters in Turkish people using computed tomography. Acta Orthopaedica et Traumatologica Turcica. 2006;29(3):227-8.