BibTex RIS Kaynak Göster

Applying of external fixator in the distal radius (An anatomic study in cadaver forearms)

Yıl 1996, Cilt: 30 Sayı: 1, 59 - 61, 11.09.2006

Öz

We performed an anatomic study in 16 cadaver forearms to determine the safety of percutaneous proximal pin placement for external fixation of distal radius fractures. Two 3mm. cortical pins were placed along the dorsoradial ridge 8 cm. proximal to the radial styloid process. Soft tissue injuries occured in 11 cases. Tendon injuries occured the extensor carpi radialis brevis in 3, extensor carpi radialis longus 4, abductor pollicis longus and brachioradialis in 1 case. Two pins transfixed the superficial branch of the radial nerve. A high degree of variability in the position of the superficial branch of the radial nerve was found and no safe zone for percutaneous pin placement could be found. We advice open pin placement for distal radius fractures because of percutaneous pin placement was not safe.

Radius distaline perkutan eksternal fiksatör uygulaması (Kadavra önkolunda yapılmış anatomik çalışma)

Yıl 1996, Cilt: 30 Sayı: 1, 59 - 61, 11.09.2006

Öz

Distal radius kırıklarının eksternal fiksatörler ile tedavisinde proksimal bölgeye perkutan çivi yerleştirilmesinin emniyetini tayin etmek amacı ile 16 kadavra ön kolunda çalışma yaptık, iki tane 3 mm. çapında kortikal uçlu çivi radius'un processus styloideus'un 8 cm. proksimaline dorsoradial kenar boyunca yerleştirildi. 11 vakada yumuşak doku yaralanması görüldü. 3 vakada abduktor pollicis longus ve bir vakada brachioradialisde tendon yaralanmaları görüldü, iki çivi radial sinirin süperfisyal dalım delip geçmişti. Radial sinirin superfisyal daimin anatomik yerleşiminde yüksek derecede değişebilirlik olduğu saptandı ve perkutan çivi yerleştirilmesi için emniyet bölgesi bulunamadı. Perkutan çivi yerleştirilmesinin emniyetli olmamasından dolayı biz distal radius kırıklarında çivilerin, açık yerleştirilmesini tavsiye etmekteyiz.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Deneysel Çalışma
Yazarlar

Ercan Olcay Bu kişi benim

Mehmet Asik Bu kişi benim

Murat Mert Bu kişi benim

Ayhan Kara Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1996 Cilt: 30 Sayı: 1

Kaynak Göster

APA Olcay, E., Asik, M., Mert, M., Kara, A. (2006). Applying of external fixator in the distal radius (An anatomic study in cadaver forearms). Acta Orthopaedica Et Traumatologica Turcica, 30(1), 59-61. https://doi.org/10.3944/aott.v30i1.4151
AMA Olcay E, Asik M, Mert M, Kara A. Applying of external fixator in the distal radius (An anatomic study in cadaver forearms). Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;30(1):59-61. doi:10.3944/aott.v30i1.4151
Chicago Olcay, Ercan, Mehmet Asik, Murat Mert, ve Ayhan Kara. “Applying of External Fixator in the Distal Radius (An Anatomic Study in Cadaver Forearms)”. Acta Orthopaedica Et Traumatologica Turcica 30, sy. 1 (Eylül 2006): 59-61. https://doi.org/10.3944/aott.v30i1.4151.
EndNote Olcay E, Asik M, Mert M, Kara A (01 Eylül 2006) Applying of external fixator in the distal radius (An anatomic study in cadaver forearms). Acta Orthopaedica et Traumatologica Turcica 30 1 59–61.
IEEE E. Olcay, M. Asik, M. Mert, ve A. Kara, “Applying of external fixator in the distal radius (An anatomic study in cadaver forearms)”, Acta Orthopaedica et Traumatologica Turcica, c. 30, sy. 1, ss. 59–61, 2006, doi: 10.3944/aott.v30i1.4151.
ISNAD Olcay, Ercan vd. “Applying of External Fixator in the Distal Radius (An Anatomic Study in Cadaver Forearms)”. Acta Orthopaedica et Traumatologica Turcica 30/1 (Eylül 2006), 59-61. https://doi.org/10.3944/aott.v30i1.4151.
JAMA Olcay E, Asik M, Mert M, Kara A. Applying of external fixator in the distal radius (An anatomic study in cadaver forearms). Acta Orthopaedica et Traumatologica Turcica. 2006;30:59–61.
MLA Olcay, Ercan vd. “Applying of External Fixator in the Distal Radius (An Anatomic Study in Cadaver Forearms)”. Acta Orthopaedica Et Traumatologica Turcica, c. 30, sy. 1, 2006, ss. 59-61, doi:10.3944/aott.v30i1.4151.
Vancouver Olcay E, Asik M, Mert M, Kara A. Applying of external fixator in the distal radius (An anatomic study in cadaver forearms). Acta Orthopaedica et Traumatologica Turcica. 2006;30(1):59-61.