BibTex RIS Kaynak Göster

Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths

Yıl 1996, Cilt: 30 Sayı: 4, 407 - 410, 11.09.2006

Öz

In recent years, developments in diagnosis and treatment of extremity length discrepancies led to the need of a most sensitive, easiest, cheapest and least harmful technique for the measurement of the length of the extremities. That CT has been introduced as a frequently used technique for extremity length measurement and it was shown to be superior to orthoroentgenographic technique in cadaveric studies made CT to be used routinely on this topic. CT and orthoroentgenography had no superiority to each other in terms of precise measurement in the subjects without flexion contracture. But in cases with flexion contracture, inaccurate measurements are obtained with orthoroentgenography due to projectional foreshortening. The extremity length measurement were performed with orthoroentgenography and lateral CT scanogram on 40 cases with limb length discrepancy admitted to our clinics between 1993-1995. Thirty-five subjects without flexion contracture or<20¡ were evaluated as the first group and 5 cases with >20¡ as the second group. In Group 1, no statistically significant difference was found between CT scanography and orthoroentgenography (t=0,072, p>0,05). However, the difference was significant in Group 2 (t=2,764, p<0,05). It was concluded that CT lateral scanography was a more precise technique than orthoroentgenography in the cases with flexion contracture.

Ekstremite uzunluk ölçümlerinde ortoröntgenografi ile bilgisayarlı tomografik - skenografinin karşılaştırılması

Yıl 1996, Cilt: 30 Sayı: 4, 407 - 410, 11.09.2006

Öz

Son yıllarda ekstremite uzunluk farklarının tanı ve tedavisindeki gelişmeler, ekstremite uzunluklannın en duyarlı, en kolay, en ucuz ve en az zararlı bir yöntemle ölçülebilmesi gereksinimini beraberinde getirmiştir. Ekstremite uzunluk farklarının saptanmasında ortorönsgenografiden birçok yönüyle üstün olduğunun kadavra çalışmalarında kanıtlanması, tomografik ölçüm tekniğinin rutin olarak kullanılmağa başlanmasına neden olmuştur. Fleksiyon kontraktürü olmayan olgularda tomografi ve ortoröntgenografinin hassas ölçü yönünden birbirlerine üstünlükleri yoktur. Fleksiyon kontraktürü olan olgularda ortoröntgenografiik teknikte projeksiyonel kısalığa bağlı önemli ölçüm hataları olmaktadır. 1993-1995 yılları arasında kliniğimize başvuran, alt ekstremitelerinde uzunluk farkı düşündüğümüz 40 olguda ortoröntgenografi ve fateral bilgisayarlı tomografik (BT) skenografi ile uzunluk ölçümleri yapılmıştır. Fleksiyon kontraktürü olmayan veya 20'nin altında olan 35 olgu 1. küme. 20°’nin üzerinde olan 5 olgu 2. küme olarak değerlendirilmiştir. Bilinci kümede BT skenografi ile ortoröntgenografi arasında istatistiki bakımdan anlamlı bir fark saptanamamıştır, 1=0,072 P>0.05. Ancak ikinci kümede fark anlamlıdır; 1=2,764 ve p<0,05. Fleksiyon kontraktürü olan olgularda BT tateral skenografinin daha uygun bir teknik olduğu kanısına varılmıştır.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Orijinal Makale
Yazarlar

Ali Okur Bu kişi benim

Naci Ezirmik Bu kişi benim

Pinar Polat Bu kişi benim

Dursun Kaya Bu kişi benim

Bulent Alparslan Bu kişi benim

Yayımlanma Tarihi 11 Eylül 2006
Yayımlandığı Sayı Yıl 1996 Cilt: 30 Sayı: 4

Kaynak Göster

APA Okur, A., Ezirmik, N., Polat, P., Kaya, D., vd. (2006). Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths. Acta Orthopaedica Et Traumatologica Turcica, 30(4), 407-410. https://doi.org/10.3944/aott.v30i4.2028
AMA Okur A, Ezirmik N, Polat P, Kaya D, Alparslan B. Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths. Acta Orthopaedica et Traumatologica Turcica. Eylül 2006;30(4):407-410. doi:10.3944/aott.v30i4.2028
Chicago Okur, Ali, Naci Ezirmik, Pinar Polat, Dursun Kaya, ve Bulent Alparslan. “Comparison of Orthoroentgenography and CT Scanography in the Measurements of Extremity Lengths”. Acta Orthopaedica Et Traumatologica Turcica 30, sy. 4 (Eylül 2006): 407-10. https://doi.org/10.3944/aott.v30i4.2028.
EndNote Okur A, Ezirmik N, Polat P, Kaya D, Alparslan B (01 Eylül 2006) Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths. Acta Orthopaedica et Traumatologica Turcica 30 4 407–410.
IEEE A. Okur, N. Ezirmik, P. Polat, D. Kaya, ve B. Alparslan, “Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths”, Acta Orthopaedica et Traumatologica Turcica, c. 30, sy. 4, ss. 407–410, 2006, doi: 10.3944/aott.v30i4.2028.
ISNAD Okur, Ali vd. “Comparison of Orthoroentgenography and CT Scanography in the Measurements of Extremity Lengths”. Acta Orthopaedica et Traumatologica Turcica 30/4 (Eylül 2006), 407-410. https://doi.org/10.3944/aott.v30i4.2028.
JAMA Okur A, Ezirmik N, Polat P, Kaya D, Alparslan B. Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths. Acta Orthopaedica et Traumatologica Turcica. 2006;30:407–410.
MLA Okur, Ali vd. “Comparison of Orthoroentgenography and CT Scanography in the Measurements of Extremity Lengths”. Acta Orthopaedica Et Traumatologica Turcica, c. 30, sy. 4, 2006, ss. 407-10, doi:10.3944/aott.v30i4.2028.
Vancouver Okur A, Ezirmik N, Polat P, Kaya D, Alparslan B. Comparison of orthoroentgenography and CT scanography in the measurements of extremity lengths. Acta Orthopaedica et Traumatologica Turcica. 2006;30(4):407-10.