BibTex RIS Kaynak Göster

False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture

Yıl 1980, Cilt: 14 Sayı: 4, 195 - 199, 21.11.1980

Öz

A case of false aneurysm of the profunda femoris artery caused by an excessively long screw used to fix a CHS-plate to the neck of the femur is presented. The aneurysm did not become symptomatic until 20 days after insertion of the screw if painful pulsating mass appears in the upper part of the thigh after an operation about the hip in which drills ond screw were used, one should suspect a false aneurysm.

FEMUR BOYUN KIRIĞININ İNTERNAL FİKSASYONU (CTS-Plate İle) SONUCU OLUŞAN ARTERİA FEMORALİS PROFUNDANIN YALANCI ANEVRİZMASI

Yıl 1980, Cilt: 14 Sayı: 4, 195 - 199, 21.11.1980

Öz

Kliniğimizde tedavi edilen bir fernur boyun kırığı olgusunda ortaya çıkan arteria femoralis profundanın yalancı anevrizması takdim edilmektedir. Çok nadir görülen bu komplikasyon kliniğimizde ilk defa gözlenmiş ve hastaya gerekli tedavi yapılarak şifa ile sonuçlanmıştır.

Toplam 0 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Olgu Sunumu
Yazarlar

Sukru Arac Bu kişi benim

Yaser Musdal Bu kişi benim

Yayımlanma Tarihi 21 Kasım 1980
Yayımlandığı Sayı Yıl 1980 Cilt: 14 Sayı: 4

Kaynak Göster

APA Arac, S., & Musdal, Y. (1980). False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica Et Traumatologica Turcica, 14(4), 195-199. https://doi.org/10.3944/aott.v14i4.3229
AMA Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. Kasım 1980;14(4):195-199. doi:10.3944/aott.v14i4.3229
Chicago Arac, Sukru, ve Yaser Musdal. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica Et Traumatologica Turcica 14, sy. 4 (Kasım 1980): 195-99. https://doi.org/10.3944/aott.v14i4.3229.
EndNote Arac S, Musdal Y (01 Kasım 1980) False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica 14 4 195–199.
IEEE S. Arac ve Y. Musdal, “False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture”, Acta Orthopaedica et Traumatologica Turcica, c. 14, sy. 4, ss. 195–199, 1980, doi: 10.3944/aott.v14i4.3229.
ISNAD Arac, Sukru - Musdal, Yaser. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica et Traumatologica Turcica 14/4 (Kasım 1980), 195-199. https://doi.org/10.3944/aott.v14i4.3229.
JAMA Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14:195–199.
MLA Arac, Sukru ve Yaser Musdal. “False Aneurysm of the Profunda Femoris Artery Resulting from Internal Fixation (CHS-Plate) of a Femoral Neck Fracture”. Acta Orthopaedica Et Traumatologica Turcica, c. 14, sy. 4, 1980, ss. 195-9, doi:10.3944/aott.v14i4.3229.
Vancouver Arac S, Musdal Y. False aneurysm of the profunda femoris artery resulting from internal fixation (CHS-Plate) of a femoral neck fracture. Acta Orthopaedica et Traumatologica Turcica. 1980;14(4):195-9.