Araştırma Makalesi

EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS

Cilt: 29 Sayı: 3 16 Temmuz 2019
PDF İndir

EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS

Öz

Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals

Abstract

Objective: To evaluate root canal enlargement following mechanical shaping using 2 nickel titanium rotary systems in simulated curved canals.

Material and Method: Thirty simulated canals in resin blocks were divided into two experimental groups, each comprising 15 resin blocks, and prepared with Twisted files (TF) and RaCe rotary files using crown-down technique. Preoperative and postoperative photographs, taken using a digital camera, were superimposed and aberrations were recorded. The amount of resin removed was measured at 11 different points, beginning at the apical terminus of the canal. Instrument failure, outer and inner width measurements, transportation rate, and centering ability were recorded on each central canal path and differences between groups were statistically analyzed using Student’s t test.

Results: No instrument fracture occurred during preparation. RaCe instruments removed more material from the outer canal walls in the apical section (p < 0.01) and from the inner canal walls in the middle section (p < 0.01) of the canals compared to TF. However, canals prepared with TF instruments resulted in less transportation (p < 0.05) in the middle section. No significant differences were found between the two groups in terms of centering ability in apical, middle, or coronal sections.  (p > 0.05).

Conclusions: RaCe instruments removed more resin from the outside of the apical curvature and from the inner side of the coronal curvature compared to TF. In addition, mean transportation amount was significantly high for RaCe in middle section (i.e., coronal curvature). Regarding canal centering ability, however, both instruments retained original canal geometry and performed similarly.

Key words: Twisted File, RaCe, Curved root canals, Canal transportation, Centering ability, Ni-Ti rotary systems

 

 Kök Kanallarını Şekillendirmesinde İki Nikel Titanyum Alet Sisteminin Değerlendirilmesi

Amaç: Simüle edilmiş eğri kanallarda 2 nikel titanyum döner alet sistemi kullanılarak mekanik şekillendirme sonrası kök kanal genişlemesinin değerlendirilmesi.

Gereç ve Yöntem: Reçine bloklardaki otuz adet simüle edilmiş kanal, her biri 15 adet rezin bloğu içeren iki deney grubuna ayrıldı ve Twisted files (TF) ve RaCe döner eğeleri kullanılarak crown-down tekniğiyle şekillendirildi. Bir dijital kamera kullanılarak çekilen preoperatif ve postoperatif fotoğraflar çakıştırıldı ve sapmalar kaydedildi. Kaldırılan rezin miktarı, kanalın apikal sonlanmasından başlayarak 11 farklı noktada ölçülmüştür. Her bir kanal yolundaki dış ve iç genişlik ölçümleri, transportasyon oranı, merkezde kalma yeteneği ve alet kırığı kaydedildi ve gruplar arasındaki farklar Student t testi kullanılarak istatistiksel olarak analiz edildi.

Bulgular: Preparasyon sırasında alet kırılması meydana gelmedi. RaCe eğeleri TF’e kıyasla kanalların apikal kısımdaki dış kanal duvarlarından (p <0.01) ve orta kesitindeki iç kanal duvarlarından (p <0.01) daha fazla materyal kaldırdı. Ancak, TF eğeleriyle hazırlanan kanallarda orta kısımda daha az transportasyon görüldü (p < 0.05).  İki grup arasında, apikal, orta veya koronal kesitlerde merkezde kalma yeteneği açısından anlamlı fark bulunmadı (p > 0.05).

Sonuçlar: RaCe eğeleri TF’e kıyasla, apikal kurvatürün dışından ve koronal kurvatürün iç kısmından daha fazla rezin kaldırmıştır. Ek olarak, ortalama transportasyon miktarı orta kısımda RaCe için anlamlı derecede yüksekti (yani koronal eğrilik). Bununla birlikte kanalın merkezinde kalma yeteneği ile ilgili olarak, her iki enstrüman da orijinal kanal geometrisini korudu ve kanalı benzer şekilde şekillendirdi.

Anahtar kelimeler: Twisted File, RaCe, Eğri  kök kanalları, Kanal transportasyonu, Merkezde kalma yeteneği, Ni-Ti döner alet sistemleri

Anahtar Kelimeler

Kaynakça

  1. 1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269-96.
  2. 2. Esposito PT, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instruments. J Endod 1995;21:173-6.
  3. 3. Gergi R, Osta N, Bourbouze G, Zgheib C, Arbab-Chirani R, Naaman A. Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography. Int Endod J 2015;48:162-70.
  4. 4. Koch K, Brave D. Real world endo: design features of rotary files and how they affect clinical performance. Oral Health 2002;92:39–49.
  5. 5. Hulsmann M, Peters OA, Dummer PMH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 2005;10:30–76.
  6. 6. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559–67.
  7. 7. Gambarini G, Testarelli L, De Luca M, Milana V, Plotino G, Grande NM, et al. The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment. Ann Stomatol (Roma) 2013;4:152-5.
  8. 8. Pagliosa A, Sousa-Neto MD, Versiani MA, Raucci-Neto W, Silva-Sousa YT, Alfredo E. Computed tomography evaluation of rotary sys¬tems on the root canal transportation and centering ability. Brazilian oral research. 2015;29: pii: S1806-83242015000100240.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Diş Hekimliği

Bölüm

Araştırma Makalesi

Yazarlar

Şenay Yaşar Bu kişi benim

Cumhur Aydın Bu kişi benim

Yayımlanma Tarihi

16 Temmuz 2019

Gönderilme Tarihi

11 Nisan 2018

Kabul Tarihi

16 Ekim 2018

Yayımlandığı Sayı

Yıl 2019 Cilt: 29 Sayı: 3

Kaynak Göster

APA
Yaşar, Ş., Erşahan, Ş., & Aydın, C. (2019). EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 29(3), 400-406. https://doi.org/10.17567/ataunidfd.471219
AMA
1.Yaşar Ş, Erşahan Ş, Aydın C. EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS. Ata Diş Hek Fak Derg. 2019;29(3):400-406. doi:10.17567/ataunidfd.471219
Chicago
Yaşar, Şenay, Şeyda Erşahan, ve Cumhur Aydın. 2019. “EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 29 (3): 400-406. https://doi.org/10.17567/ataunidfd.471219.
EndNote
Yaşar Ş, Erşahan Ş, Aydın C (01 Temmuz 2019) EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 29 3 400–406.
IEEE
[1]Ş. Yaşar, Ş. Erşahan, ve C. Aydın, “EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS”, Ata Diş Hek Fak Derg, c. 29, sy 3, ss. 400–406, Tem. 2019, doi: 10.17567/ataunidfd.471219.
ISNAD
Yaşar, Şenay - Erşahan, Şeyda - Aydın, Cumhur. “EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 29/3 (01 Temmuz 2019): 400-406. https://doi.org/10.17567/ataunidfd.471219.
JAMA
1.Yaşar Ş, Erşahan Ş, Aydın C. EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS. Ata Diş Hek Fak Derg. 2019;29:400–406.
MLA
Yaşar, Şenay, vd. “EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, c. 29, sy 3, Temmuz 2019, ss. 400-6, doi:10.17567/ataunidfd.471219.
Vancouver
1.Şenay Yaşar, Şeyda Erşahan, Cumhur Aydın. EVALUATION OF 2 NICKEL-TITANIUM INSTRUMENT SYSTEMS IN SHAPING ROOT CANALS. Ata Diş Hek Fak Derg. 01 Temmuz 2019;29(3):400-6. doi:10.17567/ataunidfd.471219

Cited By

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.