Araştırma Makalesi

EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT

Cilt: 28 Sayı: 4 14 Ekim 2018
PDF İndir

EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT

Öz

Aim: Bioactive glass has a wide range of medical and dental applications and is a potential filler component for dental restorative materials. The aim of this study was to examine the influence of adding bioactive glass to glass ionomer based fissure sealant on its mechanical properties and fluoride releasing ability.

Material and Methods: Two experimental groups were prepared with BAG added to the powder component of the material at different ratios of %30 (BAG30) and %10 (BAG10) by weight. The glass ionomer based fissure sealant material without the addition of BAG was determined as the control group. Cylindrical shaped specimens (8mm x 2mm) were prepared from each group. Fluoride release, surface roughness and surface microhardness of the specimens were measured and the data were statistically analyzed using one way ANOVA and Wilcoxon Signed Rank tests.

Results: There was no difference between fluoride releases of the materials except the first two days. BAG30 showed the highest surface microhardness and surface roughness values. There was no significant difference between surface microhardness values of BAG30 and BAG10.

Conclusion: The results of the study showed that adding BAG did not adversely affect the mechanical and fluoride release properties of glass ionomer based fissure sealants.

Keywords: Bioactive glass, fluoride release, surface roughness, surface microhardness

BİYOAKTİF CAM İLAVE EDİLMİŞ CAM İYONOMER ESASLI FİSSÜR ÖRTÜCÜNÜN MEKANİK VE FLORİD SALINIM ÖZELLİKLERİNİN ARAŞTIRILMASI

ÖZ

 Amaç: Biyoaktif cam, medikal ve dental uygula- malarda geniş bir kullanım alanına sahiptir ve dental restoratif materyaller için potansiyel bir doldurucu bile- şendir. Bu çalışmanın amacı, cam iyonomer esaslı fis- sür örtücüye biyoaktif cam ilave edilmesinin, materya- lin mekanik ve florid salınım özellikleri üzerine etkilerini araştırmaktır. 

Gereç ve Yöntem: Cam iyonomer esaslı fissür örtü- cünün toz kısmına ağırlıkça %30 (BAC30) ve %10 (BAC10) oranlarında biyoaktif cam ilave edilerek iki farklı deney grubu elde edildi. Biyoaktif cam ilave edilmeyen materyal ise kontrol grubu olarak belirlendi. Her grup için (8mm X 2mm) silindir şeklinde örnekler hazırlandı. Tüm örneklerin florid salınım değerleri, yü- zey pürüzlülükleri ve yüzey mikrosertlikleri belirlene- rek, veriler tek yönlü ANOVA ve Wilcoxon Signed Rank testleri kullanılarak istatistiksel olarak analiz edildi.

Bulgular: İlk iki gün yapılan ölçümler haricinde, tüm günlerde yapılan ölçümlerde materyallerden yapılan florid salınım miktarları arasında anlamlı bir fark olmadığı bulundu. En yüksek yüzey pürüzlülüğü ve yüzey mikrosertlik değerlerinin BAC30 grubunda oldu- ğu gözlendi. BAC30 ve BAC10 gruplarında gözlenen yüzey pürüzlülüğü ve yüzey mikrosertlik değerleri ara- sında istatistiksel olarak anlamlı bir fark gözlenmedi.

Sonuç: Çalışmadan elde edilen sonuçlar, biyoaktif cam ilave edilmesinin cam iyonomer esaslı fissür örtücü materyalin mekanik ve florid salınım özelliklerini olumsuz yönde etkilemediğini göstermiştir.

Anahtar Kelimeler: Biyoaktif cam, florid salınımı, yüzey pürüzlülüğü, yüzey mikrosertliği

Anahtar Kelimeler

Kaynakça

  1. 1. Croll TP, Nicholson JW. Glass ionomer cements in pediatric dentistry: review of the literature. Pediatr Dent 2002;24:423-9.
  2. 2. Simonsen RJ, Neal RC. A review of the clinical application and performance of pit and fissure sealants. Aust Dent J 2011;56:45-58.
  3. 3. Berg JH, Croll TP. Glass ionomer restorative cement systems: an update. Pediatr Dent 2015;37:116-24.
  4. 4. Forsten L. Fluoride release and uptake by glass ionomer and related materials and clinical effect. Biomaterials 1998;19:503-8.
  5. 5. Haznedaroğlu E, Menteş A. Scanning electron microscope and microhardness evaluation of GIC sealant application after different enamel treatment procedures. Atatürk Üniv Diş Hek Fak Derg 2013;21:177-86.
  6. 6. Smith DC. Development of glass-ionomer cements systems. Biomaterials 1998;19:467-78.
  7. 7. Hench LL. The story of Bioglass. J Mater Sci: Mater Med 2006;17:967-78.
  8. 8. Kaur G, Pandey OP, Singh K, Homa D, Scott B, Pickrell G. A review of bioactive glasses: the structure, properties, fabrication, and apatite formation. J Biomed Mater Res 2014;102:254-74.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

14 Ekim 2018

Gönderilme Tarihi

14 Aralık 2017

Kabul Tarihi

14 Şubat 2018

Yayımlandığı Sayı

Yıl 2018 Cilt: 28 Sayı: 4

Kaynak Göster

APA
Korkut, E., Botsalı, M. S., & Şener, Y. (2018). EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 28(4), 511-517. https://doi.org/10.17567/ataunidfd.473869
AMA
1.Korkut E, Botsalı MS, Şener Y. EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT. Ata Diş Hek Fak Derg. 2018;28(4):511-517. doi:10.17567/ataunidfd.473869
Chicago
Korkut, Emre, Murat S. Botsalı, ve Yağmur Şener. 2018. “EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 28 (4): 511-17. https://doi.org/10.17567/ataunidfd.473869.
EndNote
Korkut E, Botsalı MS, Şener Y (01 Ekim 2018) EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 28 4 511–517.
IEEE
[1]E. Korkut, M. S. Botsalı, ve Y. Şener, “EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT”, Ata Diş Hek Fak Derg, c. 28, sy 4, ss. 511–517, Eki. 2018, doi: 10.17567/ataunidfd.473869.
ISNAD
Korkut, Emre - Botsalı, Murat S. - Şener, Yağmur. “EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 28/4 (01 Ekim 2018): 511-517. https://doi.org/10.17567/ataunidfd.473869.
JAMA
1.Korkut E, Botsalı MS, Şener Y. EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT. Ata Diş Hek Fak Derg. 2018;28:511–517.
MLA
Korkut, Emre, vd. “EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, c. 28, sy 4, Ekim 2018, ss. 511-7, doi:10.17567/ataunidfd.473869.
Vancouver
1.Emre Korkut, Murat S. Botsalı, Yağmur Şener. EVALUATION OF MECHANICAL AND FLUORIDE RELEASE PROPERTIES OF A BIOACTIVE GLASS ADDED GLASS IONOMER BASED FISSURE SEALANT. Ata Diş Hek Fak Derg. 01 Ekim 2018;28(4):511-7. doi:10.17567/ataunidfd.473869

Cited By

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.