EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES

Öz

Aim: The aim of the present study was to determine the effect of sodium hypochloride solution on the cyclic fatigue resistance of BioRace (BR) NiTi instrument with different tip size. Methods: Eighty BioRace instrument with two different size (BR4-35.04 and BR5-40.04) were used. These instruments were randomly divided into four group, each containing 20 files. The cyclic fatigue resistance were than tested in the following conditions; group 1, BR 4 with no immersion; group 2, BR 4 with dynamic immersion in 5.25% NaOCl at 37°C ± 1°C for 5 minute; group 3, BR 5 with no immersion; group 4, BR 5 with dynamic immersion in 5.25% NaOCl at 37°C ± 1°C for 5 minute. Then the instruments were used in stainless steel artificial root canal with a curvature of 60° and 5 mm radius. Number of cycle to failure (NCF) were measured for each group. The time to failure (TTF) in seconds were also recorded. Data were subjected to the statistical analysis. Results: Nonimmersion groups were statistically superior to immersion groups (group1>group 2 and group 3>group4) both regarding TTF and NCF. However, no significant difference was found between instruments with different tip size regardless of the immersion procedure. Conclusion: The cyclic fatigue resistance of BR instrument was affected by NaOCl immersion but not with tip size. Keywords: BioRace, cyclic fatigue resistance, sodium hypochloride Sodyum Hipokloritin Farklı Boyutlardaki Biorace Döner Aletinin Döngüsel Yorgunluk Direncine Etkisinin Değerlendirilmesi Öz Amaç: Bu çalışmanın amacı sodyum hipokloridin aynı taper değerine sahip ancak farklı uç boyutları olan BioRace (BR) döner alet sistemi eğelerinin döngüsel yorgunluğuna etkisini değerlendirmektir. Gereç ve yöntem: Bu çalışmada toplam seksen adet BioRace (BR4-35.04 ve BR5-40.04) aleti kullanıldı. Eğeler, her bir grupta 20 adet olacak şekilde rastgele 4 gruba ayrılmıştır. Daha sonra aletlerin döngüsel yorgunluğu şu şekilde test edildi; Grup 1, BR 4 hiç bir solüsyonda bekletilmeden; Grup 2: BR 4 5 dakika boyunca %5,25 NaOCl solüsyonunda 37°C ± 1°C’de dinamik uygulama sonrası ; Grup 3: BR 5 hiç bir solüsyonda bekletilmeden; Grup 4: 5 dakika boyunca %5,25 NaOCl solüsyonunda 37°C ± 1°C’de dinamik uygulama sonrası 60° kurvatür açılı ve 5 mm kurvatür yarıçaplı paslanmaz çelik bloktan üretilmiş eğimli olukta test edildi. Her bir eğenin kırılana kadarki döngü sayısı (NCF) ölçüldü. Kırılana kadarki süresi (TTF) ise saniye cinsinden kaydedildi. Elde edilen veriler istatistiksel analizler ile değerlendirildi. Bulgular: TTF ve NCF değerleri göz önüne alındığında sodyum hipokloritte bekletilmeyen gruplar bekletilen gruplardan daha dirençli bulundu. Bununla beraber, aletlerin uç boyutlarındaki farkın kırlma dirençleri üzerinde istatistiksel olarak anlamlı bir etkisinin olmadığı görüldü. Sonuç: BioRace döner aletinin döngüsel yorgunluk direnci sodyum hipokloritten etkilenirken, farklı uç boyutlarının böyle bir etki yaratmadığı görüldü. Anahtar Kelimeler: BioRace, döngüsel yorgunluk direnci, sodyum hipoklorit

Anahtar Kelimeler

Kaynakça

  1. 1. Sattapan B, Nervo GJ, Palamara JEA, Messer HH. Defects in rotary nickel–titanium files after clinical use. J Endod 2000;26:161–5.
  2. 2. Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel titanium instruments. J Endod 1997;23:77–85.
  3. 3. Pedulla E, Grande NM, Plotino G, et al. Cyclic fatigue resistance of three different nickel titanium instruments after immersion in sodium hypochlorite. J Endod 2011;37:1139–42.
  4. 4. Parashos P, Gordon I, Messer HH. Factors influencing defects of rotary nickel titanium endodontic instruments after clinical use. J Endod 2004;30:722–5.
  5. 5. Elnaghy AM, Elsaka SE. Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments. Int Endod J 2017;50:991-8
  6. 6. Peters OA, Roehlike JO, Baumann MA. Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments. J Endod 2007;33: 589–93.
  7. 7. White RR, Hays GL, Janer LR. Residual antimicrobial activity after canal irrigation with chlorhexidine. J Endod 1997;23:229–31. 

  8. 8. Bystrom A, Sundqvist G. Bacteriologic evaluation of the effect of 0.5 percent sodium hypochlorite in endodontic therapy. J Oral Surg 1983;55:307–12. 


Ayrıntılar

Birincil Dil

İngilizce

Konular

Diş Hekimliği

Bölüm

Araştırma Makalesi

Yazarlar

Yayımlanma Tarihi

15 Ekim 2020

Gönderilme Tarihi

23 Ocak 2020

Kabul Tarihi

13 Ağustos 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 30 Sayı: 4

Kaynak Göster

APA
Atav Ateş, A., & Arıcan, B. (2020). EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 30(4), 594-598. https://doi.org/10.17567/ataunidfd.780113
AMA
1.Atav Ateş A, Arıcan B. EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES. Ata Diş Hek Fak Derg. 2020;30(4):594-598. doi:10.17567/ataunidfd.780113
Chicago
Atav Ateş, Ayfer, ve Burçin Arıcan. 2020. “EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 30 (4): 594-98. https://doi.org/10.17567/ataunidfd.780113.
EndNote
Atav Ateş A, Arıcan B (01 Ekim 2020) EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 30 4 594–598.
IEEE
[1]A. Atav Ateş ve B. Arıcan, “EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES”, Ata Diş Hek Fak Derg, c. 30, sy 4, ss. 594–598, Eki. 2020, doi: 10.17567/ataunidfd.780113.
ISNAD
Atav Ateş, Ayfer - Arıcan, Burçin. “EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 30/4 (01 Ekim 2020): 594-598. https://doi.org/10.17567/ataunidfd.780113.
JAMA
1.Atav Ateş A, Arıcan B. EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES. Ata Diş Hek Fak Derg. 2020;30:594–598.
MLA
Atav Ateş, Ayfer, ve Burçin Arıcan. “EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, c. 30, sy 4, Ekim 2020, ss. 594-8, doi:10.17567/ataunidfd.780113.
Vancouver
1.Ayfer Atav Ateş, Burçin Arıcan. EFFECTS OF SODIUM HYPOCHLORIDE ON CYCLIC FATIGUE RESISTANCE OF BIORACE ROTARY INSTRUMENT WITH DIFFERENT TIP SIZES. Ata Diş Hek Fak Derg. 01 Ekim 2020;30(4):594-8. doi:10.17567/ataunidfd.780113

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.