BibTex RIS Kaynak Göster

IN VITRO COMPARISON OF TWO NEW GENERATION APEX LOCATORS

Yıl 2006, Cilt: 2006 Sayı: 1, 30 - 33, 01.01.2006

Öz

-

Kaynakça

  • Tnaz AC. Kanal tedavisinde çal ma boyutu. G Ü Dihek Fak Derg 2001; 18 :31-37.
  • Azabai M, Garcia-Otero D, de la Macorra JC. Accuracy of of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures. Int Endod J 2004; 37: 174177.
  • Kauffman AY, Keila S, Yoshpe M. Accuracy of a new apex locator: in vitro study. Int Endod J 2002; 35: 186-192.
  • Fouad AF, Reid LC. Effect of using electronic apex locators on selected endodontic treatment parameters. J Endod 2000; 26: 364-370.
  • Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol 1995; 79: 226-231.
  • 6..Mayeda DL, Simon JH, Aimar DF, Finley K. In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod 1993; 9: 545548.
  • Meares WA, Steiman HR. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locators. J Endod 2002; 28: 595598.
  • Stein TJ, Corcoran JF. Radiographic "working length" revisited. Oral Surg Oral Med Oral Pathol Radiol Endod 1992; 74: 796-800.
  • Gordon MPJ, Chandler NP. Electronic Apex Locators. Int Endod J 2004; 37:425-437.
  • Brunton PA, Dilshan A, MacFarlane TV. The effect of an apex locator on exposure to radiation during endodontic therapy. J Endod 2002; 28: 524-526.
  • Lucena-Martin C, Robles-Gijon V, Ferrer-Luque CM, de Mondelo JM. In vitro evaluation of the accuracy of three electronic apex locators. J Endod 2004; 30: 231-233.
  • Huang L. An experimental study of the principle of electronic root canal measurement. J Endod 1987; 13: 60-64.
  • El Ayouti A, Weiger R, Lost C. The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length. J Endod 2002; 28: 116-119.
  • Tinaz AC, Sevimli LS, Gorgul G, Turkoz EG. The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device. J Endod 2000; 28: 160-162

İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI

Yıl 2006, Cilt: 2006 Sayı: 1, 30 - 33, 01.01.2006

Öz

Bu in vitro çal mada iki yeni nesil apeks bulucu cihaz n apikal daralmay gösterebilme yeteneklerine göre kar la t r lmas yap ld . K rk be adet tek köklü çekilmiinsan üst keser di i kullan ld . Giri kaviteleri aç ld ktan sonra, di ler aljinat model içine gömüldü. Kök kanallariçinde %2.5’lik NaOCl varken elektronik ölçümler iki apeks bulucu cihazla (Root ZX, Apex Pointer) yap ld ve kaydedildi. Elektronik ölçümler gerçek uzunluklarla kar la t r ld . Root ZX’in ‘0.5’ ölçüm ayar nda elde edilen sonuçlar 1.72 ve 0.03 mm aral F nda yer ald . Aynartlarda Apex Pointer’ n ölçümleri ise -0.8 ile 1.52 mm aral F ndayd . Root ZX genel olarak Apex Pointer’dan daha k sa ölçümler verdi, ancak cihazlar aras nda istatistiksel olarak anlaml bir fark bulunmad (p>0.001). Her iki cihaz n da klinik olarak kullan labileceFi bulundu

Kaynakça

  • Tnaz AC. Kanal tedavisinde çal ma boyutu. G Ü Dihek Fak Derg 2001; 18 :31-37.
  • Azabai M, Garcia-Otero D, de la Macorra JC. Accuracy of of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures. Int Endod J 2004; 37: 174177.
  • Kauffman AY, Keila S, Yoshpe M. Accuracy of a new apex locator: in vitro study. Int Endod J 2002; 35: 186-192.
  • Fouad AF, Reid LC. Effect of using electronic apex locators on selected endodontic treatment parameters. J Endod 2000; 26: 364-370.
  • Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol 1995; 79: 226-231.
  • 6..Mayeda DL, Simon JH, Aimar DF, Finley K. In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod 1993; 9: 545548.
  • Meares WA, Steiman HR. The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locators. J Endod 2002; 28: 595598.
  • Stein TJ, Corcoran JF. Radiographic "working length" revisited. Oral Surg Oral Med Oral Pathol Radiol Endod 1992; 74: 796-800.
  • Gordon MPJ, Chandler NP. Electronic Apex Locators. Int Endod J 2004; 37:425-437.
  • Brunton PA, Dilshan A, MacFarlane TV. The effect of an apex locator on exposure to radiation during endodontic therapy. J Endod 2002; 28: 524-526.
  • Lucena-Martin C, Robles-Gijon V, Ferrer-Luque CM, de Mondelo JM. In vitro evaluation of the accuracy of three electronic apex locators. J Endod 2004; 30: 231-233.
  • Huang L. An experimental study of the principle of electronic root canal measurement. J Endod 1987; 13: 60-64.
  • El Ayouti A, Weiger R, Lost C. The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length. J Endod 2002; 28: 116-119.
  • Tinaz AC, Sevimli LS, Gorgul G, Turkoz EG. The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device. J Endod 2000; 28: 160-162
Toplam 14 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Makaleler
Yazarlar

Doç. Dr. Ali Cemal Tınaz Bu kişi benim

Dr. Bağdagül Kıvanç Bu kişi benim

Dt. Serkan Çınar Bu kişi benim

Dt. Sibel Tazegül Bu kişi benim

Yayımlanma Tarihi 1 Ocak 2006
Yayımlandığı Sayı Yıl 2006 Cilt: 2006 Sayı: 1

Kaynak Göster

APA Tınaz, D. D. A. C., Kıvanç, D. B., Çınar, D. S., Tazegül, D. S. (2006). İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 2006(1), 30-33.
AMA Tınaz DDAC, Kıvanç DB, Çınar DS, Tazegül DS. İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI. Ata Diş Hek Fak Derg. Ocak 2006;2006(1):30-33.
Chicago Tınaz, Doç. Dr. Ali Cemal, Dr. Bağdagül Kıvanç, Dt. Serkan Çınar, ve Dt. Sibel Tazegül. “İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 2006, sy. 1 (Ocak 2006): 30-33.
EndNote Tınaz DDAC, Kıvanç DB, Çınar DS, Tazegül DS (01 Ocak 2006) İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 2006 1 30–33.
IEEE D. D. A. C. Tınaz, D. B. Kıvanç, D. S. Çınar, ve D. S. Tazegül, “İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI”, Ata Diş Hek Fak Derg, c. 2006, sy. 1, ss. 30–33, 2006.
ISNAD Tınaz, Doç. Dr. Ali Cemal vd. “İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi 2006/1 (Ocak 2006), 30-33.
JAMA Tınaz DDAC, Kıvanç DB, Çınar DS, Tazegül DS. İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI. Ata Diş Hek Fak Derg. 2006;2006:30–33.
MLA Tınaz, Doç. Dr. Ali Cemal vd. “İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI”. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, c. 2006, sy. 1, 2006, ss. 30-33.
Vancouver Tınaz DDAC, Kıvanç DB, Çınar DS, Tazegül DS. İKİ YENİ NESİL APEKS BULUCUNUN İN VİTRO KARTILAŞTIRILMASI. Ata Diş Hek Fak Derg. 2006;2006(1):30-3.

Bu eser Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır. Tıklayınız.