Simulation and Power Flow Control Using Switching’s Method of Isolated Wind-Solar Hybrid Power Generation System with Battery Storage
Öz
In this paper, a battery-supported hybrid wind-solar energy generation
system with switching power flow control is presented to supply stable
electrical power to two laboratories at the Electric & Electronic
Engineering Department. For this
purpose, 600W 3-phase permanent magnet synchronous generator (PMSG) based on
the wind power generation system (WPGS) and the solar power generation system
(SPGS) consisting of 190W 3 pieces mono crystal solar panel were combined to
build a 1170W hybrid wind-solar power generation system (HWSPGS). The solar and wind power generation systems were used as the main
energy sources while 100 Ah 12V 6
pieces gel jeep cycle accumulator groups were used as
the energy storage device to ensure
continuity of energy. Also dynamic modeling and switching power flow control
of the battery supported the HWSPGS were performed using Matlab/Simulink in this
study. Determining the switching positions of the
charge control unit according to loading and battery charge situations of the
HWSPGS, power flow control between the generation unit and consumer was made in
planned manner. When the curves of electrical magnitudes obtained from
simulation results were examined, it was determined that no big difference
existed in electrical and mechanical magnitudes in parallel to dynamic behavior
of the installed hybrid power generation system.
Anahtar Kelimeler
Kaynakça
- [1] Chedid, R. & Rahman, S.(1997). Unit sizing and control of hybrid wind-solar power systems, IEEE Transactions on Energy Conversion, 12(1), pp. 79-85.
- [2] Bonanno, F., Consoli, A., Raciti, A., Morgana, B. & Nocera, U.(1999). Transient analysis of integrated diesel/wind/photovoltaic generation systems, IEEE Transactions on Energy Conversion, 14(2), pp. 232-238.
- [3] Habib, M. A., Said, S. A. M., El Hadidy, M. A. & Al-Zaharna, I.(1999).Optimization procedure of a hybrid photovoltaic wind energy system, Energy, 24(11), pp. 919-929.
- [4] Bayer, H. G. & Christian, L.(1996).A method for the identification of configurations of PV / wind hybrid systems for the reliable supply of small loads, Solar Energy, 57(5), pp. 381-391.
- [5] Morgan , T. R., Marshall, R. H. & Brinkworth, B. J.(1997).A refined Simulation program for the sizing and optimization of autonomous hybrid energy systems, Solar Energy, 59, pp. 205-215.
- [6] Rajendra, P. A. & Natarajan, E. (2006).Optimization of integrated photovoltaic–wind power generation systems with battery storage, Energy, 31(12), pp. 1943–1954.
- [7] Altaş, İ. H. (1993).Control strategies for maximum power tracking and energy utilization of a stand-alone photovoltaic energy system, PhD diss., The University of New Brunswick, Faculty of Engineering, Department of Electrical Engineering, Fredericton, Canada.
- [8] Diaf, S., Diaf, D., Belhamel, M., Haddadi, M. & Louche, A.(2007).A methodology for optimal sizing of autonomous hybrid PV/wind system, International Journal of Energy Policy, 35(11), pp. 5708-5718.
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
1 Eylül 2017
Gönderilme Tarihi
12 Ağustos 2017
Kabul Tarihi
14 Haziran 2017
Yayımlandığı Sayı
Yıl 2017 Cilt: 5 Sayı: 2