Estimating Optimal Wind and Storage Capacity

Cilt: 1 Sayı: 2 1 Haziran 2013
  • S. Shojaeian
  • H. Akrami
PDF İndir
EN

Estimating Optimal Wind and Storage Capacity

Öz

— Considering the growing trend of the electric power demand and the global tendency to substitute new renewable energy sources, this paper proposes a Monte Carlo based method to determine an optimal level of this substitution. Because of the limitation of the wind farms in continuous supply of electric power, hydrostatic power storage facilities are used beside them so that the electric power could be stored and fed in a continuous flow into power systems. Due to the gradual exclusion of conventional generators and a reasonable percent annual load growth, Loss Of Load Expectation (LOLE) index was used in order to calculate the amount of the wind power and the capacity of the necessary power storage facility. To this end, Loss Of Energy Expectation (LOEE) index was calculated for the first year as the reference index for the estimation of the amount of wind power and the capacity of the storage facility in consequent years. For the upcoming years, calculations have been made to account for the gradual exclusion of conventional generators in proportion to load increments. The method proposed has been implemented and simulated on IEEE-RTS test system

Anahtar Kelimeler

Kaynakça

  1. R. Billinton, H. Chen and R. Ghajar, "Time-series models for reliability evaluation of power systems including wind energy", Microelectronics Reliability, Vol. 36, no. 9, pp. 1253-1261, September, 1996.
  2. K. C. Chou and R. B. Corotis, "Simulation of hourly wind speed and array wind power", Solar Energy, Vol. 26, no. 3, pp.199-212, 1981.
  3. M. Blanchard and G. Desrochers, "Generation of auto-correlated wind speeds for wind energy conversion system studies", Solar Energy, Vol. 33, no. 6, pp.571-579, 1984.
  4. X. Wang, H. Dai and R. J. Thomas, "Reliability modeling of large wind farms and electric utility interface systems", IEEE Transactions on Power Apparatus and Systems, Vol. 103, no. 3, pp. 569-575, March, 1984.
  5. R. Karki and P. Hu, "Wind power simulation model for reliability evaluation", Proceedings of the IEEE Canadian Conference on Electrical and Computer Engineering, Saskatoon, May 1-4, pp. 541- 544, 2005.
  6. R. Karki, P. Hu and R. Billinton, "A simplified wind power generation model for reliability evaluation", IEEE Transactions on Energy Conversion, Vol. 21, no. 2, pp.533 – 540, June, 2006.
  7. R. Karki, P. Hu and R. Billinton, "Reliability evaluation of a wind power delivery system using an approximate wind model", 41st International Power Newcastle, UK, September 6th-8th, 2006.
  8. W. Wangdee, "Bulk electric system reliability simulation and application", Ph. D. thesis, University of Saskatchewan, 2005.

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

S. Shojaeian Bu kişi benim

Yayımlanma Tarihi

1 Haziran 2013

Gönderilme Tarihi

27 Şubat 2015

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2013 Cilt: 1 Sayı: 2

Kaynak Göster

APA
Shojaeian, S., & Akrami, H. (2013). Estimating Optimal Wind and Storage Capacity. Balkan Journal of Electrical and Computer Engineering, 1(2), 64-70. https://izlik.org/JA97LH72HP
AMA
1.Shojaeian S, Akrami H. Estimating Optimal Wind and Storage Capacity. Balkan Journal of Electrical and Computer Engineering. 2013;1(2):64-70. https://izlik.org/JA97LH72HP
Chicago
Shojaeian, S., ve H. Akrami. 2013. “Estimating Optimal Wind and Storage Capacity”. Balkan Journal of Electrical and Computer Engineering 1 (2): 64-70. https://izlik.org/JA97LH72HP.
EndNote
Shojaeian S, Akrami H (01 Haziran 2013) Estimating Optimal Wind and Storage Capacity. Balkan Journal of Electrical and Computer Engineering 1 2 64–70.
IEEE
[1]S. Shojaeian ve H. Akrami, “Estimating Optimal Wind and Storage Capacity”, Balkan Journal of Electrical and Computer Engineering, c. 1, sy 2, ss. 64–70, Haz. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA97LH72HP
ISNAD
Shojaeian, S. - Akrami, H. “Estimating Optimal Wind and Storage Capacity”. Balkan Journal of Electrical and Computer Engineering 1/2 (01 Haziran 2013): 64-70. https://izlik.org/JA97LH72HP.
JAMA
1.Shojaeian S, Akrami H. Estimating Optimal Wind and Storage Capacity. Balkan Journal of Electrical and Computer Engineering. 2013;1:64–70.
MLA
Shojaeian, S., ve H. Akrami. “Estimating Optimal Wind and Storage Capacity”. Balkan Journal of Electrical and Computer Engineering, c. 1, sy 2, Haziran 2013, ss. 64-70, https://izlik.org/JA97LH72HP.
Vancouver
1.S. Shojaeian, H. Akrami. Estimating Optimal Wind and Storage Capacity. Balkan Journal of Electrical and Computer Engineering [Internet]. 01 Haziran 2013;1(2):64-70. Erişim adresi: https://izlik.org/JA97LH72HP

All articles published by BAJECE are licensed under the Creative Commons Attribution 4.0 International License. This permits anyone to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited.Creative Commons Lisans