Araştırma Makalesi

Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images

Cilt: 2011 Sayı: 2 1 Şubat 2011
  • Niyazi Acer
  • Mehmet Demir
  • Tolga Uçar
  • Hıdır Pekmez
  • Atilla Göktaş
PDF İndir
EN TR

Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images

Abstract

Objective: The volumes of the eyeball and orbit have been the subject of a few studies, yet none of them have used stereological methods to estimate the volume. In the present study, we estimated the volumes of the eyeball and orbita in normal healthy men and women using the stereological method. Material and Methods: We estimated the volume of the eyeball (VE) and the volume of the orbit (VO) in normal men and women using the Cavalieri principle as a combination of a point-counting technique. We used computed tomography scans taken from 31 subjects (12 men and 19 women). Results: The mean (±SD) VO in the female subjects was 18.47±2.52 cm3 on the right side and 18.16±2.52 cm3 on the left side. The VE was 7.45±1.19 cm3 and 7.45±1.25 cm3 on the right and left sides, respectively. The mean (±SD) VO in the male subjects was 22.35±3.05 cm3 on the right side and 22.71±2.80 cm3 on the left side. The VE was 7.32±0.74 cm3 and 7.61±1.04 cm3 on the right and left sides, respectively. Conclusion: Measurement by the technique described is an easy, and quick method of assessing the volumes of the eyeball and orbit.

Keywords

Kaynakça

  1. Ronan L, Doherty CP, Delanty N, Thornton J, Fitzsimons M. Quan- titative MRI: a reliable protocol for measurement of cerebral gyri- Ş cation using stereology. Magn Reson Imaging 2006;24:265-72. [CrossRef]
  2. Akbas H, Sahin B, Eroglu L, Odaci E, Bilgic S, Kaplan S, et al. Estima- tion of the breast prosthesis volume by the Cavalieri principle us- ing magnetic resonance images. Aesth Plast Surg 2004;28:275-80. [CrossRef]
  3. Acer N, Sahin B, Usanmaz M, Tatolu H, Irmak Z. Comparison of point counting and planimetry methods for the assessment of cerebellar volume in human using magnetic resonance imaging: A stereological study. Surg Radiol Anat 2008;30:335-9. [CrossRef]
  4. Gong QY, Tan LT, Romaniuk CS, Jones B, Brunt JN, Roberts N. Determination of tumour regression rates during radiotherapy for cervical carcinoma by serial MRI: comparison of two measure- ment techniques and examination of intraobserver and interob- server variability. Br J Radiol 1999;72:62-72.
  5. McEvoy F.J. An application of image processing techniques in computed tomography image analysis. Vet Radiol Ultrasound 2007;48:528-34. [CrossRef]
  6. Sahin B, Ergur H. Assessment of the optimum section thick- ness for the estimation of liver volume using magnetic reso- nance images: a stereological gold standard study. Eur J Radiol 2006;57:96-101. [CrossRef]
  7. Chau A, Fung K, Yip L, Yap M. Orbital development in Hong Kong Chinese subjects. Ophthalmic Physiol Opt 2004;24:436-9. [CrossRef]
  8. Acer N, Sahin B, Bas O, Ertekin T, Usanmaz M. Comparison of three methods for the estimation of total intracranial volume: ste- reologic, planimetric, and anthropometric approaches. Ann Plast Surg 2007;58:48-53. [CrossRef]

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Niyazi Acer Bu kişi benim

Mehmet Demir Bu kişi benim

Tolga Uçar Bu kişi benim

Hıdır Pekmez Bu kişi benim

Atilla Göktaş Bu kişi benim

Yayımlanma Tarihi

1 Şubat 2011

Gönderilme Tarihi

6 Ağustos 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2011 Cilt: 2011 Sayı: 2

Kaynak Göster

APA
Acer, N., Demir, M., Uçar, T., Pekmez, H., & Göktaş, A. (2011). Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images. Balkan Medical Journal, 2011(2), 184-188. https://doi.org/10.5174/tutfd.2010.03473.3
AMA
1.Acer N, Demir M, Uçar T, Pekmez H, Göktaş A. Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images. Balkan Medical Journal. 2011;2011(2):184-188. doi:10.5174/tutfd.2010.03473.3
Chicago
Acer, Niyazi, Mehmet Demir, Tolga Uçar, Hıdır Pekmez, ve Atilla Göktaş. 2011. “Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images”. Balkan Medical Journal 2011 (2): 184-88. https://doi.org/10.5174/tutfd.2010.03473.3.
EndNote
Acer N, Demir M, Uçar T, Pekmez H, Göktaş A (01 Şubat 2011) Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images. Balkan Medical Journal 2011 2 184–188.
IEEE
[1]N. Acer, M. Demir, T. Uçar, H. Pekmez, ve A. Göktaş, “Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images”, Balkan Medical Journal, c. 2011, sy 2, ss. 184–188, Şub. 2011, doi: 10.5174/tutfd.2010.03473.3.
ISNAD
Acer, Niyazi - Demir, Mehmet - Uçar, Tolga - Pekmez, Hıdır - Göktaş, Atilla. “Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images”. Balkan Medical Journal 2011/2 (01 Şubat 2011): 184-188. https://doi.org/10.5174/tutfd.2010.03473.3.
JAMA
1.Acer N, Demir M, Uçar T, Pekmez H, Göktaş A. Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images. Balkan Medical Journal. 2011;2011:184–188.
MLA
Acer, Niyazi, vd. “Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images”. Balkan Medical Journal, c. 2011, sy 2, Şubat 2011, ss. 184-8, doi:10.5174/tutfd.2010.03473.3.
Vancouver
1.Niyazi Acer, Mehmet Demir, Tolga Uçar, Hıdır Pekmez, Atilla Göktaş. Estimation of the Eyeball and Orbital Volume Using the Cavalieri Principle on Computed Tomography Images. Balkan Medical Journal. 01 Şubat 2011;2011(2):184-8. doi:10.5174/tutfd.2010.03473.3