Araştırma Makalesi

The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats

Cilt: 2012 Sayı: 2 1 Şubat 2012
  • Gülten Erken
  • Melek Bor Küçükatay
  • Sebahat Turgut
  • Haydar Ali Erken
  • Selçuk Çömlekçi
  • Ümit Divrikli
  • Osman Genç
PDF İndir
EN TR

The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats

Abstract

Objective: The aim of this study was to investigate the effects of the electromagnetic field generated from the 1800 MHz radiofrequency radiation (EF) on erythrocyte rheological parameters and erythrocyte zinc levels. Material and Methods: Twenty-four male Wistar Albino rats were randomly grouped as follows: 1) two control groups and 2) study groups: i) Group A: EF exposed group (2.5 h/day for 30 days, the phone on stand-by), and ii) Group B: EF exposed group (2.5 min/day for 30 days, the phone ringing in silent mode). At the end of the experimental period erythrocyte rheological parameters such as erythrocyte deformability and aggregation were determined by an ectacytometer. Erythrocyte zinc level, which affects hemorheological parameters, was also measured by atomic absorption spectrophotometer. Results: Erythrocyte deformability was decreased in both study groups but the decrease in group A was not statistically significant. Exposure to EF did not have any significant effect on erythrocyte aggregation. On the other hand, erythrocyte zinc level was significantly reduced in both study groups. Conclusion: Exposure to EF may have decreased tissue oxygenation due to reduced erythrocyte deformability. Decrease in erythrocyte zinc level may have caused the impairment in erythrocyte deformability. Turkish Başlık: 1800 MHz Radyofrekans Radyasyondan Kaynaklanan Elektromanyetik Alanın Eritrositlerin Reolojik Parametreleri ve Çinko Seviyeleri Üzerindeki Etkisi Anahtar Kelimeler: Elektromanyetik alan, eritrosit agregasyonu, eritrosit deformabilitesi, cep telefonu, eser element Giriş: Bu çalışmanın amacı 1800 MHz radyofrekans radyasyondan kaynaklanan elektromanyetik alanın (EF) eritrositlerin reolojik parametreleri ve çinko seviyeleri üzerindeki etkilerini araştırmaktır. Gereç ve Yöntemler: Yirmi dört adet erkek Wistar Albino sıçan, rastgele olarak aşağıdaki gruplara ayrıldı: 1) İki kontrol grubu ve 2) Çalışma grupları: i) A grubu: EF' ye maruz kalan grup (Telefon stand-by pozisyonundayken, 30 gün boyunca 2.5 saat/gün), ve ii) B grubu: EF' ye maruz kalan grup (Telefon sessiz modda çalarken, 30 gün boyunca 2.5 dakika/gün). Deneysel priyodun sonunda, eritrosit deformabilitesi ve agregasyonu gibi, eritrosit reolojik parametreleri bir ektasitometre aracılığıyla saptandı. Hemoreolojik parametreleri etkileyebilen eritrosit çinko seviyeleri ise atomik absorbsiyon spektrofotometresiyle ölçüldü. Sonuçlar: Eritrosit deformabilitesi tüm gruplarda kontrole göre azaldı. Fakat bu azalma A grubu için istatistiksel olarak anlamlı düzeyde değildi. EF' ye maruziyet eritrosit agregasyonu üzerinde anlamlı bir değişikliğe yol açmadı. Diğer taraftan eritrosit çinko düzeyleri tüm çalışma gruplarında kontrole göre anlamlı düzeyde azalmış bulundu. Tartışma: EF' ye maruziyet eritrosit deformabilitesini düşürerek doku oksijenasyonunu azaltmış olabilir. Eritrosit deformabilitesindeki bozulma ise eritrosit çinko seviyesindeki düşüşten kaynaklanmış olabilir.

Keywords

Kaynakça

  1. Hocking B, Westerman R. Neurological effects of radiofrequency radiation. Occup Med 2003;53:123-7. [CrossRef]
  2. Atay T, Aslan A, Heybeli N, Hürriyet Aydoğan N, Baydar Ml, et al. Effects of 1800 MHz electromagnetic field emitted from cellular phones on bone tissue. Balkan Med J 2009;26:292-6.
  3. Jauchem JR. Exposure to extremely-low-frequency electromagnetic fields and radiofrequency radiation: cardiovascular effects in humans. Int Arch Occup Environ Health 1997;70:9-21. [CrossRef]
  4. Nakamura H, Matsuzaki I, Hatta K, Nobukuni Y, Kambayashi Y, Ogino K. Nonthermal effects of mobile-phone frequency microwaves on uteroplacental functions in pregnant rats. Reprod Toxicol 2003;17:321-6. [CrossRef]
  5. Shiga T, Maeda N, Kon K. Erythrocyte rheology. Crit Rev Oncol Hematol 1990;10:9-48. [CrossRef]
  6. Neu B, Meiselman HJ. Depletion-Mediated Red Blood Cell Aggrega- tion in Polymer Solutions. Biophys J 2002;83:2482-90. [CrossRef]
  7. Meiselman HJ. Hemorheologic alterations in hypertension: chicken or egg? Clin Hemorheol Microcirc 1999;21:195-200.
  8. Fraga CG. Relevance, essentiality and toxicity of trace elements in human health. Mol Aspects Med 2005;26:235-44. [CrossRef]

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yazarlar

Gülten Erken Bu kişi benim

Melek Bor Küçükatay Bu kişi benim

Sebahat Turgut Bu kişi benim

Haydar Ali Erken Bu kişi benim

Selçuk Çömlekçi Bu kişi benim

Ümit Divrikli Bu kişi benim

Osman Genç Bu kişi benim

Yayımlanma Tarihi

1 Şubat 2012

Gönderilme Tarihi

7 Ağustos 2014

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2012 Cilt: 2012 Sayı: 2

Kaynak Göster

APA
Erken, G., Küçükatay, M. B., Turgut, S., Erken, H. A., Çömlekçi, S., Divrikli, Ü., & Genç, O. (2012). The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats. Balkan Medical Journal, 2012(2), 139-143. https://doi.org/10.5152/balkanmedj.2011.021
AMA
1.Erken G, Küçükatay MB, Turgut S, vd. The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats. Balkan Medical Journal. 2012;2012(2):139-143. doi:10.5152/balkanmedj.2011.021
Chicago
Erken, Gülten, Melek Bor Küçükatay, Sebahat Turgut, vd. 2012. “The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats”. Balkan Medical Journal 2012 (2): 139-43. https://doi.org/10.5152/balkanmedj.2011.021.
EndNote
Erken G, Küçükatay MB, Turgut S, Erken HA, Çömlekçi S, Divrikli Ü, Genç O (01 Şubat 2012) The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats. Balkan Medical Journal 2012 2 139–143.
IEEE
[1]G. Erken vd., “The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats”, Balkan Medical Journal, c. 2012, sy 2, ss. 139–143, Şub. 2012, doi: 10.5152/balkanmedj.2011.021.
ISNAD
Erken, Gülten - Küçükatay, Melek Bor - Turgut, Sebahat - Erken, Haydar Ali - Çömlekçi, Selçuk - Divrikli, Ümit - Genç, Osman. “The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats”. Balkan Medical Journal 2012/2 (01 Şubat 2012): 139-143. https://doi.org/10.5152/balkanmedj.2011.021.
JAMA
1.Erken G, Küçükatay MB, Turgut S, Erken HA, Çömlekçi S, Divrikli Ü, Genç O. The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats. Balkan Medical Journal. 2012;2012:139–143.
MLA
Erken, Gülten, vd. “The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats”. Balkan Medical Journal, c. 2012, sy 2, Şubat 2012, ss. 139-43, doi:10.5152/balkanmedj.2011.021.
Vancouver
1.Gülten Erken, Melek Bor Küçükatay, Sebahat Turgut, Haydar Ali Erken, Selçuk Çömlekçi, Ümit Divrikli, Osman Genç. The Effects of Electromagnetic Fields Generated from 1800 MHz Cell Phones on Erythrocyte Rheological Parameters and Zinc Level in Rats. Balkan Medical Journal. 01 Şubat 2012;2012(2):139-43. doi:10.5152/balkanmedj.2011.021