Araştırma Makalesi

Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye

Cilt: 8 Sayı: 3 15 Mayıs 2025
PDF İndir
EN TR

Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye

Öz

This extensive research has resulted in the ingenious design of an intelligent composite wall, which incorporates internal and external thermal insulation to effectively deal with the cold climate conditions prevalent in Sivas, Türkiye. Outdoor temperatures in this region drop significantly at night, requiring effective thermal management solutions. The main focus of this research is to determine the minimum insulation thickness required to prevent surface condensation on the walls, which can cause potential problems. In particular, the study helps to identify the effect of thermal insulation on these variables through a series of elaborate and precise heat and mass transfer calculations, rigorously carried out over a range of different scenarios, including indoor and outdoor temperature conditions and variations in relative humidity. The results of such extensive analysis clearly show that the effectiveness and efficiency of thermal insulation becomes increasingly pronounced and evident as the indoor relative humidity exceeds the 70% threshold. In situations where the internal relative humidity is low, the need for increased insulation thickness approaches negligible or minimal levels. Significantly, the comprehensive analysis shows that when the outdoor relative humidity is increased significantly, from 50% to 80%, there is an inverse and measurable increase in the water vapour partial pressure in the external environment. An increase in the water vapour partial pressure results in a reduction in water vapour transmission and therefore reduces the possibility of condensation in that environment.

Anahtar Kelimeler

Etik Beyan

Since this study did not involve any studies on animals or humans, ethics committee approval was not obtained.

Kaynakça

  1. Aelenei D, Henriques FM. 2008. Analysis of the condensation risk on exterior surface of building envelopes. Energy Build 40(10): 1866-1871.
  2. Anonymous. Air Barrier vs Vapor Barrier: How Do They Differ? URL: https://metalcon.com/blog/air-barrier-vs-vapor-barrier-how-do-they-differ/ (accessed date: May 2, 2025).
  3. Anonymous. n.d. What is EPS? URL: https://epslastro.com/en/what-is-eps/ (accessed date: May 2, 2025).
  4. Arslan O, Kose R. 2006. Thermoeconomic optimization of insulation thickness considering condensed vapor in buildings. Energy Build 38(12): 1400-1408.
  5. Bademlioğlu A, Kaynaklı Ö, Yamankaradeniz N. 2018. The effect of water vapor diffusion resistance factor of insulation materials for outer walls on condensation. Isı Bil Tek Derg, 38(2): 15-23.
  6. Bellia L, Minichiello F. 2003. A simple evaluator of building envelope moisture condensation according to a European standard. Build Environ 38(3): 457-468.
  7. Çağman S, Ünver Ü. 2023. Determination of condensation and its effect on insulation and wall envelope layers. Eur J Tech 13(2): 68-73.
  8. Cho W, Iwamoto S, Kato S. 2016. Condensation risk due to variations in airtightness and thermal insulation of an office building in warm and wet climate. Energies 9(11): 875.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Enerji

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

15 Mayıs 2025

Gönderilme Tarihi

29 Kasım 2024

Kabul Tarihi

30 Nisan 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 8 Sayı: 3

Kaynak Göster

APA
Aktemur, C., & Çakır, M. T. (2025). Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye. Black Sea Journal of Engineering and Science, 8(3), 891-898. https://doi.org/10.34248/bsengineering.1593337
AMA
1.Aktemur C, Çakır MT. Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye. BSJ Eng. Sci. 2025;8(3):891-898. doi:10.34248/bsengineering.1593337
Chicago
Aktemur, Cenker, ve Mutlu Tarık Çakır. 2025. “Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye”. Black Sea Journal of Engineering and Science 8 (3): 891-98. https://doi.org/10.34248/bsengineering.1593337.
EndNote
Aktemur C, Çakır MT (01 Mayıs 2025) Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye. Black Sea Journal of Engineering and Science 8 3 891–898.
IEEE
[1]C. Aktemur ve M. T. Çakır, “Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye”, BSJ Eng. Sci., c. 8, sy 3, ss. 891–898, May. 2025, doi: 10.34248/bsengineering.1593337.
ISNAD
Aktemur, Cenker - Çakır, Mutlu Tarık. “Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye”. Black Sea Journal of Engineering and Science 8/3 (01 Mayıs 2025): 891-898. https://doi.org/10.34248/bsengineering.1593337.
JAMA
1.Aktemur C, Çakır MT. Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye. BSJ Eng. Sci. 2025;8:891–898.
MLA
Aktemur, Cenker, ve Mutlu Tarık Çakır. “Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye”. Black Sea Journal of Engineering and Science, c. 8, sy 3, Mayıs 2025, ss. 891-8, doi:10.34248/bsengineering.1593337.
Vancouver
1.Cenker Aktemur, Mutlu Tarık Çakır. Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye. BSJ Eng. Sci. 01 Mayıs 2025;8(3):891-8. doi:10.34248/bsengineering.1593337

                           24890