Öz

The seismic safety assessment of registered heritage buildings requires analysis strategies that reconcile the mechanical complexity of historical masonry with the principles of minimum intervention and material compatibility. This study evaluates the seismic performance of a registered historical masonry structure located on block 157, plot 63 in the Hazro district of Diyarbakır, in the seismically active southeast of Türkiye, and develops conservation-compatible retrofitting proposals. The building, comprising a ground floor and roof level within a 17.24 m × 6.72 m rectangular plan, was discretized with three-dimensional solid finite elements in Abaqus/CAE on the basis of laser-scanning survey geometry. The seismic demand was defined by the DD-2 design spectrum of the Turkish Earthquake Hazard Map (SS = 0.477; S1 = 0.161; PGA = 0.207g; site class ZD), and the three-component records of AFAD-TADAS station 2106 from the February 6, 2023 Pazarcık (Mw 7.7) earthquake were baseline-corrected, band-pass filtered (0.10–20 Hz, Butterworth), and spectrally matched to the target spectrum using wavelet-based adjustment prior to nonlinear time history analysis. Masonry mechanical parameters were assigned per wall typology in accordance with Table 6.1 of the Turkish Guideline for the Management of Earthquake Risks in Historical Structures (TYDRYK). Modal analysis yielded closely spaced translational modes at 13.75 Hz and 14.32 Hz (T ≈ 0.07 s), consistent with the high lateral stiffness of thick-walled masonry. Under the most unfavorable load combination, maximum compressive and tensile stresses remained at 0.06 MPa and 0.07 MPa, respectively, the peak displacement was 1.05 mm, and the maximum drift ratio (0.1–0.2%) remained well below the 0.7% Controlled Damage limit. A localized capacity deficiency identified in lime-mortar brick masonry zones is resolved by the proposed interventions, after which the structure satisfies the Controlled Damage performance level under the DD-2 hazard.

Anahtar Kelimeler

Etik Beyan

Ethics committee approval was not required for this study because of there was no study on animals or humans.

Kaynakça

  1. AFAD. (2018). Türkiye Deprem Tehlike Haritası [Turkish earthquake hazard map]. Disaster and Emergency Management Authority. https://tdth.afad.gov.tr/
  2. AFAD. (2023). TADAS – Turkish Accelerometric Database and Analysis System. Disaster and Emergency Management Authority. https://tadas.afad.gov.tr/
  3. Al Atik, L., & Abrahamson, N. (2010). An improved method for nonstationary spectral matching. Earthquake Spectra, 26(3), 601–617. https://doi.org/10.1193/1.3459159
  4. Altunışık, A. C., Adanur, S., Genç, A. F., Günaydın, M., & Okur, F. Y. (2017). An investigation of the seismic behaviour of an ancient masonry bastion using non-destructive and numerical methods. Experimental Mechanics, 57(2), 245–259. https://doi.org/10.1007/s11340-016-0239-x
  5. Bayraktar, A., Altunışık, A. C., Sevim, B., & Türker, T. (2011). Seismic response of a historical masonry minaret using a finite element model updated with operational modal testing. Journal of Vibration and Control, 17(1), 129–149. https://doi.org/10.1177/1077546309353288
  6. Betti, M., & Vignoli, A. (2008). Assessment of seismic resistance of a basilica-type church under earthquake loading: Modelling and analysis. Advances in Engineering Software, 39(4), 258–283. https://doi.org/10.1016/j.advengsoft.2007.01.020
  7. Binda, L., Saisi, A., & Tiraboschi, C. (2000). Investigation procedures for the diagnosis of historic masonries. Construction and Building Materials, 14(4), 199–233. https://doi.org/10.1016/S0950-0618(00)00018-0
  8. CEN. (2005a). Eurocode 6: Design of masonry structures – Part 1-1: General rules for reinforced and unreinforced masonry structures (EN 1996-1-1). European Committee for Standardization.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Deprem Mühendisliği, İnşaat Yapım Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

15 Kasım 2026

Gönderilme Tarihi

24 Temmuz 2026

Kabul Tarihi

16 Eylül 2026

Yayımlandığı Sayı

Yıl 2026 Cilt: 9 Sayı: 6

Kaynak Göster

APA
Ateş, T. (2026). Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye. Black Sea Journal of Engineering and Science, 9(6), 2955-2966. https://doi.org/10.34248/bsengineering.2002792
AMA
1.Ateş T. Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye. BSJ Eng. Sci. 2026;9(6):2955-2966. doi:10.34248/bsengineering.2002792
Chicago
Ateş, Tahir. 2026. “Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye”. Black Sea Journal of Engineering and Science 9 (6): 2955-66. https://doi.org/10.34248/bsengineering.2002792.
EndNote
Ateş T (15 Kasım 2026) Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye. Black Sea Journal of Engineering and Science 9 6 2955–2966.
IEEE
[1]T. Ateş, “Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye”, BSJ Eng. Sci., c. 9, sy 6, ss. 2955–2966, Kas. 2026, doi: 10.34248/bsengineering.2002792.
ISNAD
Ateş, Tahir. “Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye”. Black Sea Journal of Engineering and Science 9/6 (15 Kasım 2026): 2955-2966. https://doi.org/10.34248/bsengineering.2002792.
JAMA
1.Ateş T. Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye. BSJ Eng. Sci. 2026;9:2955–2966.
MLA
Ateş, Tahir. “Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye”. Black Sea Journal of Engineering and Science, c. 9, sy 6, Kasım 2026, ss. 2955-66, doi:10.34248/bsengineering.2002792.
Vancouver
1.Tahir Ateş. Seismic Performance Assessment of a Historical Masonry Structure Using Spectrally Matched Records of the 2023 Kahramanmaraş Earthquake and Conservation-Compatible Retrofitting Proposals: A Case Study from Diyarbakır–Hazro, Türkiye. BSJ Eng. Sci. 15 Kasım 2026;9(6):2955-66. doi:10.34248/bsengineering.2002792