Araştırma Makalesi

Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System

Cilt: 9 Sayı: 6 15 Kasım 2026
PDF İndir
EN TR

Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System

Öz

This study compares a single tuned mass damper and a bi-tuned mass damper in a single-degree-of-freedom wind turbine tower–nacelle model. Four configurations are evaluated under the same total auxiliary mass: the classical Den Hartog design, a single damper retuned with the common objective, a bi-tuned damper with equal branch masses, and a bi-tuned damper with a free mass split. The objective combines normalized displacement and acceleration responses over a frequency band around the main natural frequency, and the designs are optimized for total auxiliary mass ratios of 0.02, 0.05, and 0.20. A coarse sweep is followed by a toolbox-free particle swarm optimization; independent differential evolution, extended-bound searches, equal-split coverage, and internal consistency checks are used for verification. The equal-branch bi-tuned damper gave a lower band objective than the retuned single damper at all three mass ratios. The free-split search did not improve on the equal split at the two lower mass ratios and provided only a small additional gain at 0.20. The retuned single damper performed best under single-frequency harmonic loading, whereas both bi-tuned configurations yielded marginally lower objective values under the chirp load. For ten zero-mean Kaimal realizations normalized to 100 N root mean square, paired analysis at a mass ratio of 0.20 identified small but statistically significant differences; the equal-branch bi-tuned damper had the lowest mean objective. Frequency-response and ±10% natural-frequency-deviation analyses showed that two tuning branches redistribute the response across the band, but do not provide unconditional detuning robustness. The practical choice therefore depends not only on the objective value but also on stroke demand, transmitted force, component count, and maintenance requirements.

Anahtar Kelimeler

Etik Beyan

Ethics committee approval was not required because the study did not involve human participants or animals.

Kaynakça

  1. Abé, M., & Fujino, Y. (1994). Dynamic characterization of multiple tuned mass dampers and some design formulas. Earthquake Engineering & Structural Dynamics, 23(8), 813–835. https://doi.org/10.1002/eqe.4290230802
  2. Bertollucci Colherinhas, G., Petrini, F., de Morais, M. V. G., & Bontempi, F. (2021). Optimal design of passive-adaptive pendulum tuned mass damper for the global vibration control of offshore wind turbines. Wind Energy, 24(6), 573–595. https://doi.org/10.1002/we.2590
  3. Cao, H. Q., & Tran, N.-A. (2023). Multi-objective optimal design of double tuned mass dampers for structural vibration control. Archive of Applied Mechanics, 93(5), 2129–2144. https://doi.org/10.1007/s00419-023-02376-6
  4. Den Hartog, J. P. (1985). Mechanical vibrations (4th ed.). Dover Publications.
  5. Han, D., Wang, W., Li, X., & Su, X. (2022). Optimization design of multiple tuned mass dampers for semi-submersible floating wind turbine. Ocean Engineering, 264, Article 112536. https://doi.org/10.1016/j.oceaneng.2022.112536
  6. Holm, S. (1979). A simple sequentially rejective multiple test procedure. Scandinavian Journal of Statistics, 6(2), 65–70.
  7. IEC. (2005). Wind turbines – Part 1: Design requirements (IEC 61400-1:2005, 3rd ed.). International Electrotechnical Commission.
  8. Igusa, T., & Xu, K. (1994). Vibration control using multiple tuned mass dampers. Journal of Sound and Vibration, 175(4), 491–503. https://doi.org/10.1006/jsvi.1994.1341

Ayrıntılar

Birincil Dil

İngilizce

Konular

Akustik ve Gürültü Kontrolü (Mimari Akustik hariç), Dinamikler, Titreşim ve Titreşim Kontrolü, Makine Teorisi ve Dinamiği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

15 Kasım 2026

Gönderilme Tarihi

2 Ağustos 2026

Kabul Tarihi

16 Eylül 2026

Yayımlandığı Sayı

Yıl 2026 Cilt: 9 Sayı: 6

Kaynak Göster

APA
Yaylagül, Z., & Aggümüş, H. (2026). Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System. Black Sea Journal of Engineering and Science, 9(6), 3058-3070. https://doi.org/10.34248/bsengineering.2009208
AMA
1.Yaylagül Z, Aggümüş H. Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System. BSJ Eng. Sci. 2026;9(6):3058-3070. doi:10.34248/bsengineering.2009208
Chicago
Yaylagül, Zeynel, ve Hüseyin Aggümüş. 2026. “Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System”. Black Sea Journal of Engineering and Science 9 (6): 3058-70. https://doi.org/10.34248/bsengineering.2009208.
EndNote
Yaylagül Z, Aggümüş H (15 Kasım 2026) Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System. Black Sea Journal of Engineering and Science 9 6 3058–3070.
IEEE
[1]Z. Yaylagül ve H. Aggümüş, “Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System”, BSJ Eng. Sci., c. 9, sy 6, ss. 3058–3070, Kas. 2026, doi: 10.34248/bsengineering.2009208.
ISNAD
Yaylagül, Zeynel - Aggümüş, Hüseyin. “Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System”. Black Sea Journal of Engineering and Science 9/6 (15 Kasım 2026): 3058-3070. https://doi.org/10.34248/bsengineering.2009208.
JAMA
1.Yaylagül Z, Aggümüş H. Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System. BSJ Eng. Sci. 2026;9:3058–3070.
MLA
Yaylagül, Zeynel, ve Hüseyin Aggümüş. “Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System”. Black Sea Journal of Engineering and Science, c. 9, sy 6, Kasım 2026, ss. 3058-70, doi:10.34248/bsengineering.2009208.
Vancouver
1.Zeynel Yaylagül, Hüseyin Aggümüş. Comparison of Single- and Bi-Tuned Mass Dampers under Equal Total Auxiliary Mass and Different Dynamic Loads in a Wind Turbine Tower–Nacelle System. BSJ Eng. Sci. 15 Kasım 2026;9(6):3058-70. doi:10.34248/bsengineering.2009208