Öz

Aim: The purpose is to evaluate the complications that occur in implanted locator supported removable dentures for 2 years clinically and radiologically.
Materials and methods: Study between the years of 2014-2019, was performed on 121 patients who underwent 284 dental implants and came to their controls at the 12th and 24th months. Patients included in the retrospective study were 52 men and 69 women. Complications detected in the first 24 months after the implant supported prosthesis applied; relining and rebasing, loss of retention (housing removal, wear of the retaining clip) and fracture in the base of prosthesis were recorded and evaluated. Data were analyzed using One‐way ANOVA and Tukey's HSD tests. A P value of < 0.05 was considered statistically significant.
Results: In implant-supported removable prostheses, there are significant differences were found between the increasing complication rates at 12th and 24th months (p <0.05). The most common complication at the end of 24th month in overdenture prosthesis with implant supported locator holder applied to the maxilla and mandible, respectively; relining of prosthesis (11.57%), rebasing of prosthesis (6.6%), loss of retention (5.79%) and prosthetic base fracture (4.13%).
Conclusion: Based on the data analyzed in our study, removable prostheses showed different types and frequency of complications. Treatment of implant-supported overdenture prostheses, routine control of the prostheses is important.

Anahtar Kelimeler

Kaynakça

  1. Arvidson K, Bystedt H, Frykholm A, et al. Five‐year prospective follow‐up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles. Clinical Oral Implants Research. 1998;9(4):225-234.
  2. Block MS, Akin R, Chang A, et al. Skeletal and dental movements after anterior maxillary advancement using implant-supported distraction osteogenesis in dogs. Journal of oral and maxillofacial surgery. 1997;55(12):1433-1439.
  3. Brägger U, Häfeli U, Huber B, et al. Evaluation of postsurgical crestal bone levels adjacent to non‐submerged dental implants. Clinical Oral Implants Research. 1998;9(4):218-224.
  4. Buser D, Mericske‐stern R, Pierre Bernard JP, et al. Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants. Clinical oral implants research. 1997;8(3):161-172.
  5. Dennis Flanagan D, DABOI A. The Legends of Implant Dentistry with the History of Transplantology and Implantology. The Journal of Oral Implantology. 2010;36(3):247.
  6. Naert I, Quirynen M, Theuniers G, et al. Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report. The Journal of prosthetic dentistry. 1991;65(5):671-680.
  7. Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study. International Journal of Prosthodontics. 2000;13(2).
  8. Dhillon N, Chowdhury SR, Kumar P, et al. Managing prosthetic complication in implant-retained overdenture. Medical journal, Armed Forces India. 2015;71(Suppl 2):S444.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Diş Hekimliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Ağustos 2020

Gönderilme Tarihi

12 Haziran 2020

Kabul Tarihi

19 Haziran 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 4 Sayı: 2

Kaynak Göster

APA
Fadhil, S. M. T., & Mumcu, E. (2020). Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study. Journal of Biotechnology and Strategic Health Research, 4(2), 150-155. https://doi.org/10.34084/bshr.751908
AMA
1.Fadhil SMT, Mumcu E. Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study. J Biotechnol and Strategic Health Res. 2020;4(2):150-155. doi:10.34084/bshr.751908
Chicago
Fadhil, Sadeq Mohammed Taqi, ve Emre Mumcu. 2020. “Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study”. Journal of Biotechnology and Strategic Health Research 4 (2): 150-55. https://doi.org/10.34084/bshr.751908.
EndNote
Fadhil SMT, Mumcu E (01 Ağustos 2020) Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study. Journal of Biotechnology and Strategic Health Research 4 2 150–155.
IEEE
[1]S. M. T. Fadhil ve E. Mumcu, “Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study”, J Biotechnol and Strategic Health Res, c. 4, sy 2, ss. 150–155, Ağu. 2020, doi: 10.34084/bshr.751908.
ISNAD
Fadhil, Sadeq Mohammed Taqi - Mumcu, Emre. “Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study”. Journal of Biotechnology and Strategic Health Research 4/2 (01 Ağustos 2020): 150-155. https://doi.org/10.34084/bshr.751908.
JAMA
1.Fadhil SMT, Mumcu E. Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study. J Biotechnol and Strategic Health Res. 2020;4:150–155.
MLA
Fadhil, Sadeq Mohammed Taqi, ve Emre Mumcu. “Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study”. Journal of Biotechnology and Strategic Health Research, c. 4, sy 2, Ağustos 2020, ss. 150-5, doi:10.34084/bshr.751908.
Vancouver
1.Sadeq Mohammed Taqi Fadhil, Emre Mumcu. Evaluation of complications in implant-supported locator retained removable dentures: 24 Months Retrospective Study. J Biotechnol and Strategic Health Res. 01 Ağustos 2020;4(2):150-5. doi:10.34084/bshr.751908