Investigation of Indoor Air Quality in a Hospital: A Case Study from Şanlıurfa, Turkey
Öz
Most people spent more than %80 of their time indoors. In Turkey, hospitals are prominent governmental places. Its importance becomes from more visits than others. An investigation about the interior air quality across the polyclinics of one of the most visited hospital of Şanlıurfa, Turkey, was conducted in this study. Indoor air quality in terms of PM, CO, CO2, temperature and relative humidity was investigated. The performed measurements were revealed that the levels of PM2.5 and PM10 in surgery, urology, neurology, heart surgeon and eye diseases polyclinic were higher than the threshold limits in international standards set by WHO and ASHAE. CO2, a surrogate for indoor pollutants emitted by humans. In this research, CO2 was found to be under the standards in radiology, tomography, X-ray, orthopedics polyclinics and emergency services. Conversely, it was measured above the standards across the other polyclinics. Temperature and relative humidity were found unsuitable; CO was found to meet the standards. The significantly high rates were considered as a result of inadequate ventilation, lack of proper cleaning, low ceiling and crowd of patients. The old age of the building could create risk of dust particles, CO2, temperature, humidity in the hospital for the health of the staff and patients visiting the polyclinics.
Anahtar Kelimeler
Kaynakça
- Araújo M.B., Alagador D., Cabeza M., Nogués‐Bravo D., Thuiller W., (2011), Climate change threatens European conservation areas, Ecology Letters, 14(5), 484-492.
- ASHRAE, (2001), The ASHRAE Handbook 2001: Fundamentals, Chapter 8: Thermal Comfort, Atlanta, USA, 544ss.
- Beelen R.G., Hoek G., van den Brandt P.A., Goldbohm R.A., Fischer P., Schouten L.J., Jerrett M., Hughes E., Armstrong B., Brunekreef B., (2008), Long-term effects of traffic-related air pollution on mortality in a Dutch cohort (NLCS-AIR Study), Environmental Health Perspectives, 116(2), 196–202.
- Bruce N., Perez-Padilla R., Albalak R., (2000), Indoor air pollution in developing countries: amajor environmental and public health challenge, Bulletin of the World Health Organization, 78(9), 1078-1092.
- Chaloulakou A., Mavroidis I., Duci A., (2003), Indoor and outdoor carbon monoxide concentration relationships at different microenvironments in the Athens area, Chemosphere, 52(6), 1007-1019.
- Chamseddine A., El-Fadel M., (2015), Exposure to air pollutants in hospitals: indoor–outdoor correlations, Sustainable Development, 2, 707-716.
- Chang T., Ren D., Shen Z., Huang Y., Sun J., Cao J., Pan H., (2017), Indoor air pollution levels in decorated residences and public places over Xi’an China, Aerosol and Air Quality Research, 17, 2197-2205.
- Chen C., Zhao B., (2011), Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor, Atmospheric Environment, 45(2), 275–288.
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yazarlar
Yayımlanma Tarihi
31 Ocak 2019
Gönderilme Tarihi
27 Temmuz 2018
Kabul Tarihi
28 Eylül 2018
Yayımlandığı Sayı
Yıl 2019 Cilt: 5 Sayı: 1
Cited By
Indoor Air Quality Level at Medical Clinics, University Hospital in Klang Valley, Malaysia
Malaysian Journal of Medicine and Health Sciences
https://doi.org/10.47836/mjmhs.18.6.22Indoor Air Quality of A Medical Faculty Hospital and Its Effect On Those In The Environment
Genel Tıp Dergisi
https://doi.org/10.54005/geneltip.1403173Comparative assessment of indoor air quality and comfort parameters in government and non-government hospitals in southwestern Bangladesh
Next Research
https://doi.org/10.1016/j.nexres.2024.100063BİR ÜNİVERSİTE HASTANESİNDE İŞ SAĞLIĞI GÜVENLİĞİNE YÖNELİK SES VE IŞIK ŞİDDETİ İLE HAVA KALİTESİNİN ARAŞTIRILMASI
Eskişehir Türk Dünyası Uygulama ve Araştırma Merkezi Halk Sağlığı Dergisi
https://doi.org/10.35232/estudamhsd.1560932