Derleme

Determination of The Hip Stem Loosening Using Vibration Method

Cilt: 3 Sayı: 1 27 Haziran 2019
PDF İndir
EN

Determination of The Hip Stem Loosening Using Vibration Method

Abstract

Aseptic loosening is a common problem in total hip replacement surgery. Routine radiological imaging techniques are used for postoperative diagnosis. The alternative technique is required to develop because of the low success rate in current diagnostic techniques. The purpose of this study is to develop the new method to diagnose the aseptic loosening of the stem using vibration technique. Two different experimental setups were established in this study, vibrational and cyclic loading tests. In the vibrational test, the bone-prosthetic models were vibrated from the distal femur at a certain frequency and then the vibration data were taken via accelerometer from the trochanter region of the femur. The vibration data were converted to the frequency domain for evaluations. The stability of the femur-prosthesis system was determined by evaluating the fundamental frequency change and harmonics generated at the FFT analysis. In the cyclic loading test, the femur-prosthesis system was forced to fatigue at a maximum amplitude of 1700 N and 1 Hz frequency. After every 5000 cycles in the test, the femoral prosthesis system was connected to the vibrational test and the loosening of the system was considered. After 115000 cycles, the harmonic frequencies were observed and the amplitude value of the fundamental frequency was decreased. The experiments were stopped when the stem was pulled out easily from the femur. As the degree of the loosening increased, the number of the harmonics increased and the fundamental frequency values decreased. In conclusion, the vibration method can be used as an alternative technique to determine the degree of the hip stem loosening.

Keywords

Kaynakça

  1. [1]. H. Malchau, P. Herberts, T. Eisler, G. Garellick, and P. Soderman, "The Swedish Total Hip Replacement Register " J. Bone Joint Surg. Am., vol. 86-A, pp. 2-20, 2002.
  2. [2]. K. E. Dreinhofer, "Indications for total hip replacement: comparison of assessments of orthopaedic surgeons and referring physicians," Annals of the Rheumatic Diseases, vol. 65, pp. 1346-1350, 2006.
  3. [3]. A. P. Georgiou and J. L. Cunningham, "Accurate diagnosis of hip prosthesis loosening using a vibrational technique," Clinical Biomechanics, vol. 16, pp. 315-323, 2001.
  4. [4]. L. C. Pastrav, S. V. N. Jaecques, I. Jonkers, G. Perre, and M. Mulier, "In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses," Journal of Orthopaedic Surgery and Research, vol. 4, p. 10, 2009.
  5. [5]. J. S. Rieger, S. Jaeger, C. Schuld, J. P. Kretzer, and R. G. Bitsch, "A vibrational technique for diagnosing loosened total hip endoprostheses: An experimental sawbone study," Medical Engineering & Physics, vol. 35, pp. 329-337, 2013.
  6. [6]. A. A. Alshuhri, T. P. Holsgrove, A. W. Miles, and J. L. Cunningham, "Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements," Medical Engineering & Physics, vol. 37, pp. 739-745, 2015.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Derleme

Yazarlar

Yayımlanma Tarihi

27 Haziran 2019

Gönderilme Tarihi

16 Kasım 2018

Kabul Tarihi

30 Ocak 2019

Yayımlandığı Sayı

Yıl 1970 Cilt: 3 Sayı: 1

Kaynak Göster

APA
Çelik, T., & Kisioglu, Y. (2019). Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences, 3(1), 73-77. https://izlik.org/JA95RA38DP
AMA
1.Çelik T, Kisioglu Y. Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences. 2019;3(1):73-77. https://izlik.org/JA95RA38DP
Chicago
Çelik, Talip, ve Yasin Kisioglu. 2019. “Determination of The Hip Stem Loosening Using Vibration Method”. European Journal of Engineering and Natural Sciences 3 (1): 73-77. https://izlik.org/JA95RA38DP.
EndNote
Çelik T, Kisioglu Y (01 Haziran 2019) Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences 3 1 73–77.
IEEE
[1]T. Çelik ve Y. Kisioglu, “Determination of The Hip Stem Loosening Using Vibration Method”, European Journal of Engineering and Natural Sciences, c. 3, sy 1, ss. 73–77, Haz. 2019, [çevrimiçi]. Erişim adresi: https://izlik.org/JA95RA38DP
ISNAD
Çelik, Talip - Kisioglu, Yasin. “Determination of The Hip Stem Loosening Using Vibration Method”. European Journal of Engineering and Natural Sciences 3/1 (01 Haziran 2019): 73-77. https://izlik.org/JA95RA38DP.
JAMA
1.Çelik T, Kisioglu Y. Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences. 2019;3:73–77.
MLA
Çelik, Talip, ve Yasin Kisioglu. “Determination of The Hip Stem Loosening Using Vibration Method”. European Journal of Engineering and Natural Sciences, c. 3, sy 1, Haziran 2019, ss. 73-77, https://izlik.org/JA95RA38DP.
Vancouver
1.Talip Çelik, Yasin Kisioglu. Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences [Internet]. 01 Haziran 2019;3(1):73-7. Erişim adresi: https://izlik.org/JA95RA38DP