BibTex RIS Kaynak Göster

Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter

Yıl 2013, Cilt: 10 Sayı: 12, - , 21.03.2016

Öz

Early complete dislodgement of stent from the balloon catheter is a rare complication and may lead to severe coronary ischaemia. In such cases, the first treatment option is the retrieval of the material, while another option is to squeeze the undeployed stent into vessel wall by inflating the balloon. Although several methods and devices are available for stent removal, retrieval procedure is likely to be unsuccessful in many cases. In this paper, we presented two cases of early dislodgement of drug-eluting coronary stents during coronary angioplasty procedure and other methods subsequently performed in such cases.

Kaynakça

  • Schatz RA, Baim DS, Leon M, et al. Clinical experience with the Palmaz-Schatz coronary stent: Initial results of a multicenter study. Circulation 1991; 83: 148-61 86
  • Veldhuijzen FL, Bonnier HJ, Michels HR, et al. Retrieval of undeployed stents from the right coronary artery: Report of two cases. Cathet Cardiovasc Diagn 1993; 30: 245-8
  • Cishek MB, Laslett L, Gershony G: Ballon catheter re- trieval of dislodged coronary artery stents: A novel tech- nique. Cathet Cardiovasc Diagn 1995; 34: 350-2
  • Foster-Smith KW, Garratt KN, Higano ST, et al. Retrieval techniques for managing flexible intracoronary stent mis- placement. Cathet Cardiovasc Diagn 1993; 30: 63-8

Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter

Yıl 2013, Cilt: 10 Sayı: 12, - , 21.03.2016

Öz

Stentin balon üzerinden erken ayrılması nadir görülen bir komplikasyondur ve ciddi koroner iskemiye yol açabilir. Bu durumda materyalin geri alınması ilk tedavi seçeneğidir. Bir başka yöntem ise açılmamış durumdaki stentin akımı bozmadan bulunduğu ortamda stabilize edilmesidir. Ayrılan stentin ortamdan uzaklaştırılması için kullanılan birçok metod ve cihaz olmasına rağmen vakaların çoğunda geri alma işlemi başarısız olmaktadır. Bu yazıda, koroner anjiyoplasti işlemi sırasında stentin erken ayrılması ve sonrasında uygulanan yöntemleri ele alan iki olgu sunuldu

Kaynakça

  • Schatz RA, Baim DS, Leon M, et al. Clinical experience with the Palmaz-Schatz coronary stent: Initial results of a multicenter study. Circulation 1991; 83: 148-61 86
  • Veldhuijzen FL, Bonnier HJ, Michels HR, et al. Retrieval of undeployed stents from the right coronary artery: Report of two cases. Cathet Cardiovasc Diagn 1993; 30: 245-8
  • Cishek MB, Laslett L, Gershony G: Ballon catheter re- trieval of dislodged coronary artery stents: A novel tech- nique. Cathet Cardiovasc Diagn 1995; 34: 350-2
  • Foster-Smith KW, Garratt KN, Higano ST, et al. Retrieval techniques for managing flexible intracoronary stent mis- placement. Cathet Cardiovasc Diagn 1993; 30: 63-8
Toplam 4 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Bölüm Olgu Sunumu
Yazarlar

Orhan Dogdu Bu kişi benim

Mikail Yarlıoglues Bu kişi benim

Erol Tulumen Bu kişi benim

Ali Taner Bu kişi benim

Yayımlanma Tarihi 21 Mart 2016
Yayımlandığı Sayı Yıl 2013 Cilt: 10 Sayı: 12

Kaynak Göster

APA Dogdu, O., Yarlıoglues, M., Tulumen, E., Taner, A. (2016). Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter. European Journal of General Medicine, 10(12).
AMA Dogdu O, Yarlıoglues M, Tulumen E, Taner A. Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter. European Journal of General Medicine. Mart 2016;10(12).
Chicago Dogdu, Orhan, Mikail Yarlıoglues, Erol Tulumen, ve Ali Taner. “Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter”. European Journal of General Medicine 10, sy. 12 (Mart 2016).
EndNote Dogdu O, Yarlıoglues M, Tulumen E, Taner A (01 Mart 2016) Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter. European Journal of General Medicine 10 12
IEEE O. Dogdu, M. Yarlıoglues, E. Tulumen, ve A. Taner, “Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter”, European Journal of General Medicine, c. 10, sy. 12, 2016.
ISNAD Dogdu, Orhan vd. “Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter”. European Journal of General Medicine 10/12 (Mart 2016).
JAMA Dogdu O, Yarlıoglues M, Tulumen E, Taner A. Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter. European Journal of General Medicine. 2016;10.
MLA Dogdu, Orhan vd. “Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter”. European Journal of General Medicine, c. 10, sy. 12, 2016.
Vancouver Dogdu O, Yarlıoglues M, Tulumen E, Taner A. Early Deployment of Drug-Eluting Coronary Stent from the Balloon Catheter. European Journal of General Medicine. 2016;10(12).