Araştırma Makalesi
BibTex RIS Kaynak Göster

The Effect of Water Flow Rate on Davis Tube Tests

Yıl 2021, Cilt: 54 Sayı: 1, 44 - 53, 10.12.2021

Öz

The effect of water flow rate on Davis tube tests was investigated in different solid ratios using low and high magnetite content samples. It was found that with increasing water flow rate Fe recovery decreased for each studied solid rate. It has been shown that the chosen solid ratio does not affect the grade regardless of the water flow rate, it has an impact on the Fe recovery.

Kaynakça

  • Ahmed M. M. 2010. Statıstıcal design application and analysis of separation effıciency in Davis tube tester, Journal of Engineering Sciences, Assiut University, Vol. 38, No. 4, pp. 1047-1058
  • Arol A.I., Aydogan A. 2004. Recovery enhancement of magnetite fines in magnetic separation, Colloids and Surfaces A: Physicochem. Eng. Aspects, 232, 151–154
  • Davis, E.W. 1955. Pioneering with Taconite: The Birth of a Minnesota Industry, 269-283, Minesota Hisstorical Society Press, 2004.
  • Haffez G.S.A. 2012. Optimization of the operating parameters affecting Davis tube magnetic tester using 2nd factorial design, Journal of Engineering Sciences, Assiut University, Vol. 40, No. 4, pp.1217-1231
  • Murariu, V., Svoboda, J. 2003. The applıcabılıty of davıs tube tests to ore separatıon by drum magnetıc separators, Physical Separation in Science and Engineering, 12, 1, pp. 1–11.
  • Safarik, I., Mucha, P., Pechoc, J., Stoklasa, J., Safarikova, M., 2001. Separation of magnetic affinity biopolymer adsorbents in a Davis tube magnetic separator, Biotechnology Letters 23: 851–855, 2001.
  • Sivrikaya, O., Arol, A. I. 2012. Evaluation of low grade iron ore deposit in Erzincan-Turkey for iron ore pellet concentrate production
  • Schulz, N.F., 1964. Determination of the magnetic separation characteristics with the Davis Magnetic Tube,Trans. SME-AIME, 229, 211–216.
  • Svoboda, J, 2004. Magnetic Technicues for the Treatment of Materials, Kluwer Academic Publishers

Davis Tüp Testlerinde Su Akış Hızının Etkisi

Yıl 2021, Cilt: 54 Sayı: 1, 44 - 53, 10.12.2021

Öz

The effect of water flow rate on Davis tube tests was investigated in different solid ratios using low and high magnetite content samples. It was found that with increasing water flow rate Fe recovery decreased for each studied solid rate. It has been shown that the chosen solid ratio does not affect the grade regardless of the water flow rate, it has an impact on the Fe recovery.

Kaynakça

  • Ahmed M. M. 2010. Statıstıcal design application and analysis of separation effıciency in Davis tube tester, Journal of Engineering Sciences, Assiut University, Vol. 38, No. 4, pp. 1047-1058
  • Arol A.I., Aydogan A. 2004. Recovery enhancement of magnetite fines in magnetic separation, Colloids and Surfaces A: Physicochem. Eng. Aspects, 232, 151–154
  • Davis, E.W. 1955. Pioneering with Taconite: The Birth of a Minnesota Industry, 269-283, Minesota Hisstorical Society Press, 2004.
  • Haffez G.S.A. 2012. Optimization of the operating parameters affecting Davis tube magnetic tester using 2nd factorial design, Journal of Engineering Sciences, Assiut University, Vol. 40, No. 4, pp.1217-1231
  • Murariu, V., Svoboda, J. 2003. The applıcabılıty of davıs tube tests to ore separatıon by drum magnetıc separators, Physical Separation in Science and Engineering, 12, 1, pp. 1–11.
  • Safarik, I., Mucha, P., Pechoc, J., Stoklasa, J., Safarikova, M., 2001. Separation of magnetic affinity biopolymer adsorbents in a Davis tube magnetic separator, Biotechnology Letters 23: 851–855, 2001.
  • Sivrikaya, O., Arol, A. I. 2012. Evaluation of low grade iron ore deposit in Erzincan-Turkey for iron ore pellet concentrate production
  • Schulz, N.F., 1964. Determination of the magnetic separation characteristics with the Davis Magnetic Tube,Trans. SME-AIME, 229, 211–216.
  • Svoboda, J, 2004. Magnetic Technicues for the Treatment of Materials, Kluwer Academic Publishers
Toplam 9 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Genel Jeoloji
Bölüm Araştırma Makaleleri
Yazarlar

Mahmut Emre Taçoğlu Bu kişi benim

Mustafa Şen Bu kişi benim

Emre Toprak Bu kişi benim

Saruhan Saklar Bu kişi benim

Yayımlanma Tarihi 10 Aralık 2021
Yayımlandığı Sayı Yıl 2021 Cilt: 54 Sayı: 1

Kaynak Göster

APA Taçoğlu, M. E., Şen, M., Toprak, E., Saklar, S. (2021). The Effect of Water Flow Rate on Davis Tube Tests. Geosound, 54(1), 44-53.
AMA Taçoğlu ME, Şen M, Toprak E, Saklar S. The Effect of Water Flow Rate on Davis Tube Tests. Geosound. Aralık 2021;54(1):44-53.
Chicago Taçoğlu, Mahmut Emre, Mustafa Şen, Emre Toprak, ve Saruhan Saklar. “The Effect of Water Flow Rate on Davis Tube Tests”. Geosound 54, sy. 1 (Aralık 2021): 44-53.
EndNote Taçoğlu ME, Şen M, Toprak E, Saklar S (01 Aralık 2021) The Effect of Water Flow Rate on Davis Tube Tests. Geosound 54 1 44–53.
IEEE M. E. Taçoğlu, M. Şen, E. Toprak, ve S. Saklar, “The Effect of Water Flow Rate on Davis Tube Tests”, Geosound, c. 54, sy. 1, ss. 44–53, 2021.
ISNAD Taçoğlu, Mahmut Emre vd. “The Effect of Water Flow Rate on Davis Tube Tests”. Geosound 54/1 (Aralık 2021), 44-53.
JAMA Taçoğlu ME, Şen M, Toprak E, Saklar S. The Effect of Water Flow Rate on Davis Tube Tests. Geosound. 2021;54:44–53.
MLA Taçoğlu, Mahmut Emre vd. “The Effect of Water Flow Rate on Davis Tube Tests”. Geosound, c. 54, sy. 1, 2021, ss. 44-53.
Vancouver Taçoğlu ME, Şen M, Toprak E, Saklar S. The Effect of Water Flow Rate on Davis Tube Tests. Geosound. 2021;54(1):44-53.